| Modell | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 | |
| Ausgabe | Gleichspannung | 5V | 12V | 24V | 48V |
| Nennstrom | 10A | 5A | 2,5A | 1.25A | |
| Aktueller Bereich | 0 ~ 10A | 0 ~5A | 0 -2.5A | 0-1.25A | |
| Nennleistung | 50W | 60W | 60W | 60W | |
| Welligkeit und Rauschen (max.) | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
| Voltage ADJ Range | 5 -6V | 12-15V | 24 – 30V | 48 ~ 56V | |
| Spannungstoleranz | ±2,0% | ±1,0% | ±1,0% | ±1,0% | |
| Linienregulierung | ±1,0% | ±1,0% | ±1,0% | ±1,0% | |
| Lastregulierung | ±1,5% | ±1,0% | ±1,0% | ±1,0% | |
| Setup, Rise Time Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC bei Volllast |
||||
| Hold Up Time (Typ.) | 50ms/230VAC 20ms/115VAC bei Volllast |
||||
| Eingang | Spannungsbereich | 85~264VAC 120~370 VDC |
|||
| Frequenzbereich | 47~63Hz | ||||
| Effizienz (typ.) | 78% | 86% | 88% | 87% | |
| AC Current (Typ.) | 1.8A/115VAC 1A/230VAC |
||||
| Einschaltstrom (typ.) | COLD START: 30A/115VAC 60A/230VAC |
||||
| Leckstrom | <1mA/240VAC | ||||
| Schutz | Überlast | 105% ~ 150% rated output power | |||
| Schutzart: Konstantstrombegrenzung, automatische Wiederherstellung nach Beseitigung des Fehlerzustands | |||||
| Over-voltage | 6.25-7.25V | 15.6 – 18V | 31.2-36V | 57.6 – 64.8V | |
| Schutzart: O/P-Spannung abschalten, zur Wiederherstellung wieder einschalten | |||||
| Funktion | DC Signal | Relay contact rating (max.): 30V/1A resistive | |||
| Umfeld | Arbeitsfeuchtigkeit | 20% ~ 90%RH non-condensing | |||
| Storage Temp Humidity | -40°C ~ +85°C, 10% ~ 95%RH | ||||
| Temperaturkoeffizient | ±0.03%/°C (0 – 50°C) | ||||
| Vibration | Component: 10 – 500Hz, 2G 10min./1 cycle, the period for 60min. each along X, Y, and Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
| Sicherheit & EMV | Sicherheitsstandards | UL508, UL60950-1, TUV EN60950-1 approved | |||
| Spannungsbeständig | l/P-0/P: 3KVAC l/P-FG:2KVAC 0/P-FG: 0.5KVAC |
||||
| Isolationswiderstand | l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH | ||||
| EMC Emission | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 | ||||
| EMC Immunity | Compliance to EN6100(M-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
| Andere | MTBF | 299.2K hrs min. MIL-HDBK-217F (25°C) | |||
| Dimension | 40*90*100mm (W*H*D) | ||||
| Verpackung | 0.33Kg; 60pcs/20Kg/0.82CUFT | ||||
| Notiz | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature. | ||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 of & 47uf parallel capacitor. | |||||
| 3. Tolerance: includes set up tolerance, line regulation, and load regulation. | |||||
| 4. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. | |||||
| 5. The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the setup time. | |||||
Großhandel mit 60-W-DIN-Schienen-Netzteil mit Einzelausgang
MDR-60 is a slim line DIN rail Class I switching power supply.
Entworfen mit einem vollständig isolierten Kunststoffgehäuse, um Benutzerkontakt und die Gefahr eines Stromschlags zu verhindern. Mit einem Wirkungsgrad von bis zu 88% kann diese Serie nur durch freie Luftkonvektion bis zu 60 °C gekühlt werden, was die Zuverlässigkeit und Lebensdauer des Netzteils deutlich erhöht. Zu den weiteren Standardmerkmalen gehören der niedrige Stromverbrauch im Leerlauf, um Energie zu sparen, Kurzschluss-, Überlast- und Überspannungsschutz sowie ein DC-OK-Relaiskontakt mit LED-Anzeige zur Überwachung des Netzteilstatus. Falls vorhandenWenn Sie Fragen haben, zögern Sie bitte nicht, uns unter zu kontaktieren E-Mail: [email protected]
- Beschreibung
Advantage Material: For all switching Power Supplies, Faithful Brand adopts pure copper materials for Power inductors & Main transformers & IC Transformers.
And we make transformers and power inductors with pure copper all by ourselves, in order to make sure the materials use pure copper to keep the high efficiency of power supply working performance and reduce the cost of power supply.
Der Betriebstemperaturbereich des Produkts beträgt: -10 °C bis +50 °C
Global wide input volatge range 100V to 264V AC
This product is small and easy to install, which is space and cost-efficient.
Das Produkt kann durch Konvektion natürlicher Luft gekühlt werden.
LED Indicator lamp for power on
Für dieses Produkt gilt eine 24-monatige Garantie.
Save space and cost
Was sind die besten Stromversorgungsprodukte für Ihr Unternehmen?
Steigern Sie Ihr Geschäft mit den hochwertigen Stromversorgungsprodukten von WEHO.
Fragen Sie einen Experten