Match the input and load
Check the available AC or DC input against the specification. Add the demand of devices that start together before choosing an output version.
LRS-35 is a 35W-class single-output enclosed power-supply family with a 99×82×30mm enclosure. The 12V, 15V, 24V and 48V versions list output-current ranges of 0~3A, 0~2.4A, 0~1.5A and 0~0.8A respectively.
Input: 85~264VAC or 120~373VDC, 47~63Hz. Listed efficiencies are 86%, 88%, 88% and 90% in the same voltage order. Working temperature is -20℃ to +70℃.
Εάν έχετε οποιεσδήποτε ερωτήσεις, μη διστάσετε να επικοινωνήσετε μαζί μας στο E-mail: [email protected]
The WEHO LRS-35 is an enclosed AC-to-DC supply for auxiliary loads such as a sensor board, a small display or a controller. Choose the version that matches the devices on that rail; the five voltages are separate models, not settings on one supply.
Scroll the table to compare all five outputs.
| Parameter | LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-48 |
|---|---|---|---|---|---|
| DC output voltage and current | 5V 0~7A | 12V 0~3A | 15V 0~2.4A | 24V 0~1.5A | 48V 0~0.8A |
| Εύρος τάσης εισόδου | 85~264VAC / 120~373VDC, 47~63Hz | ||||
| Διαστάσεις | 99×82×30mm | ||||
| Αποδοτικότητα | 86% | 86% | 88% | 88% | 90% |
| Θερμοκρασία εργασίας | -20℃~+70℃ | ||||
| Ripple & noise | 120mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
| Ρύθμιση γραμμής | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Ρύθμιση φορτίου | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Ρύθμιση τάσης εξόδου | ±10% | ±10% | ±10% | ±10% | ±10% |
| Inrush current | Ρεύμα ψυχρής εκκίνησης 45A/230VAC | ||||
| Προστασία υπερφόρτωσης | 110%~150% διακόπτει την έξοδο, αυτόματη ανάκτηση | ||||
| Άλλη προστασία | Προστασία από υπερένταση/Προστασία από βραχυκύκλωμα | ||||
| Timing (setup / rise / hold-up) | 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified. | ||||
| Αντοχή στην τάση | I/P-O/P:1,5kV I/P-FG:1,5kV O/P-FG:0,5kV 1 λεπτό | ||||
| Αντοχή μόνωσης | I/P-O/P I/P-FG O/P-FG:100MOhms/500VDC/25℃/70%RH | ||||
| Βάρος | 0.23kg | ||||
| Συσκευασία | 44×36.5×19.5CM/80PCS/16kg | ||||
99 × 82 × 30 mm (L × W × H)
Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face.
Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. An axis that extends beyond the specified range does not extend the rating. Use the curve for the applicable output voltage and observe its input and mounting conditions.

Check the available AC or DC input against the specification. Add the demand of devices that start together before choosing an output version.

Allow space beyond the case for wire bends and access to all five terminals. Use the drawing for mounting-hole positions.

Measure near the supply during the longest duty cycle. Use the derating curves for that temperature and input voltage.

Check what the machine does after an overload clears. Have a qualified installer review protective earthing and branch protection; automatic recovery is not an emergency stop.
These examples cover the auxiliary electronics, not the main machine load.

A matched rail can power a sign timer, its control interface or a small group of compatible LED modules. Use downstream current regulation where required.
Example: LRS-35-24 · 24 V, 0–1.5 A

Use a matched rail for door-status sensors and a small operator interface. Budget lock pickup current separately; do not size the entire locker bank from the sensor load.
Example: LRS-35-12 · 12 V, 0–3 A

A local supply can serve a compatible sensor board and sequence indicators at a carton-forming station. Power the drive and safety circuit separately.
Example: LRS-35-15 · 15 V, 0–2.4 A

Consider a matched supply for fixture status, presence sensing or trigger interfaces. Use a dedicated test source where the device under test needs controlled excitation or precision measurements.
Example: LRS-35-24 · 24 V, 0–1.5 A
AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.
No. Each unit has one nominal output. Choose the voltage required by the load; the trim adjustment cannot turn one model into another.
The datasheet calls this a 35 W series and lists a current range for each output. It does not give a separate continuous-power rating per version. Check the running and startup loads for the selected model.
Use the ripple and noise figure in the selected model’s specification column. Compare it with the device’s tolerance before deciding whether downstream filtering is needed.
No. Cold-start current is drawn on the input side when the supply starts. For the DC load, use the output-current range for your model.
The sheet lists setup and rise times but gives no separate hold-up time. Verify the complete system if a controller must stay on during an interruption.
Not necessarily. Read the derating curves for the installed temperature and input voltage. Room temperature alone does not tell you how hot the supply runs inside a cabinet.
Give the model or required DC voltage, running and startup current, quantity and cabinet conditions. Note any unusual load or restart requirements.
Ενισχύστε την επιχείρησή σας με ποιοτικά προϊόντα τροφοδοσίας WEHO.
Ρωτήστε έναν ειδικό