Overview
The LRS-75 is a single-output AC/DC power supply. Its proposed role is auxiliary DC power for inspection fixtures and packaging-quality electronics, with test drives and safety functions designed separately. The specified overall dimensions are 99 × 97 × 30 mm. The near-square footprint is useful when planning a small machine base or protected inspection station. State the required electronics rail and duty cycle when selecting the model.
Why Choose LRS-75?
Use the compact body deliberately
The specified overall dimensions are 99 × 97 × 30 mm. The near-square outline suits early layout studies for small inspection fixtures, with protective enclosure and connection space assessed separately.
Match the inspection accessory
The LRS-75 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Select a rail accepted by the camera, gauge or interface board rather than treating an inspection station as a single generic load.
Budget losses by voltage variant
The listed efficiencies are 87%, 87%, 88% and 89% for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Using the selected model figure supports a more relevant preliminary electronics-compartment heat budget.
Sequence inspection startup
The setup/rise row gives 1000 ms and 30 ms at 230 VAC, and 2000 ms and 30 ms at 115 VAC. The input-dependent setup figures make power-on readiness a concrete integration question for the inspection electronics.
Features, Benefits & Advantages
| Χαρακτηριστικό | Benefit in equipment design |
|---|---|
| Published ripple-and-noise values | The listed ripple-and-noise values are 120 mVp-p, 120 mVp-p, 150 mVp-p and 200 mVp-p for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Noise-sensitive inspection interfaces still need a measurement at their own input. |
| Steady-state regulation figures | Line regulation and load regulation are each listed as ±0.5%. These figures give a starting point for a rail budget, with wiring drop and dynamic loads evaluated separately. |
| Local output adjustment | The DC-voltage adjustment range is listed as ±10%. Set and verify a rail accepted by the interface board; do not treat the trim function as sensor excitation control. |
| Documented protective behavior | Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Restart and fault-isolation behavior belong in the inspection station design review. |