Product Categories

LRS-75 Series 75W Single Output Enclosed Switching Power Supply (LRS-75-12 / LRS-75-24)

Single Output: The LRS-75 is offered in 12V, 15V, 24V and 48V versions, with listed current ranges of 0~6A, 0~5A, 0~3.2A and 0~1.6A respectively. Select the voltage and current for cameras, routers, LED lighting or other equipment loads.
Input and Adjustment: Input is 85~264VAC or 120~373VDC, 47~63Hz. DC output-voltage adjustment is ±10%; verify the connected equipment’s acceptable range.
Protection: Overload protection cuts off the output at 110%~150% with automatic recovery; overcurrent and short-circuit protection are also listed.
Dimensions: 99×97×30mm; working temperature -20℃ to +70℃.
Si tiene alguna pregunta, no dude en contactarnos al correo electrónico: [email protected]

Overview

The LRS-75 is a single-output AC/DC power supply. Its proposed role is auxiliary DC power for inspection fixtures and packaging-quality electronics, with test drives and safety functions designed separately. The specified overall dimensions are 99 × 97 × 30 mm. The near-square footprint is useful when planning a small machine base or protected inspection station. State the required electronics rail and duty cycle when selecting the model.

Why Choose LRS-75?

Use the compact body deliberately

The specified overall dimensions are 99 × 97 × 30 mm. The near-square outline suits early layout studies for small inspection fixtures, with protective enclosure and connection space assessed separately.

Match the inspection accessory

The LRS-75 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Select a rail accepted by the camera, gauge or interface board rather than treating an inspection station as a single generic load.

Budget losses by voltage variant

The listed efficiencies are 87%, 87%, 88% and 89% for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Using the selected model figure supports a more relevant preliminary electronics-compartment heat budget.

Sequence inspection startup

The setup/rise row gives 1000 ms and 30 ms at 230 VAC, and 2000 ms and 30 ms at 115 VAC. The input-dependent setup figures make power-on readiness a concrete integration question for the inspection electronics.

Features, Benefits & Advantages

Característica Benefit in equipment design
Published ripple-and-noise values The listed ripple-and-noise values are 120 mVp-p, 120 mVp-p, 150 mVp-p and 200 mVp-p for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Noise-sensitive inspection interfaces still need a measurement at their own input.
Steady-state regulation figures Line regulation and load regulation are each listed as ±0.5%. These figures give a starting point for a rail budget, with wiring drop and dynamic loads evaluated separately.
Local output adjustment The DC-voltage adjustment range is listed as ±10%. Set and verify a rail accepted by the interface board; do not treat the trim function as sensor excitation control.
Documented protective behavior Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Restart and fault-isolation behavior belong in the inspection station design review.
Especificación LRS-75-12 LRS-75-15 LRS-75-24 LRS-75-48
Tensión de salida CC, corriente 12V 0~6A 15V 0~5A 24V 0~3.2A 48V 0~1.6A
Ola y ruido 120mVp-p 120mVp-p 150mVp-p 200mVp-p
Estabilidad del cable de entrada ±0,5% ±0,5% ±0,5% ±0,5%
Estabilidad de carga ±0,5% ±0,5% ±0,5% ±0,5%
Eficiencia 87% 87% 88% 89%
Rango ajustable para voltaje CC ±10% ±10% ±10% ±10%
Rango de voltaje de entrada 85~264VAC / 120~373VDC, 47~63Hz
Corriente de impacto Corriente de arranque en frío 50A/230VAC
Protección contra sobrecarga 110%~150%corta la salida, recuperación automática
Otra protección Protección contra sobrecorriente/protección contra cortocircuitos
Timing (setup / rise / hold-up) 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified.
Voltaje de soporte I/P-O/P:1,5 kV I/P-FG:1,5 kV O/P-FG:0,5 kV 1 minuto
Resistencia de aislamiento I/P-O/P I/P-FG O/P-FG:100M Ohms /500VDC/25℃/70%RH
Temperatura de trabajo -20℃~+70℃
Dimensión 99×97×30mm
Peso 0.3kg
Embalaje 42.5×32.5×19.5CM/60PCS/18kg

Mechanical dimensions

LRS-75 — dimensions in millimetres
Body length99 mm
Body width97 mm
Body height30 mm

The body dimensions and mounting-hole dimensions are different references. The vector drawing below retains the dimensions printed in the WEHO original.

On a small screen, swipe the drawing horizontally to inspect every dimension. No separate drawing image or script download is required.

Exact mechanical drawing from the WEHO original. Units: mm. Use the printed body, mounting and hole dimensions separately.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Typical Service Conditions

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


Select 90–132VAC or 180–264VAC manually before energizing, then verify the chosen DC output and polarity.

Input matching: LRS-75 versus the selector example

The illustration shows the LRS-350 manual-range example; do not transfer its 90–132/180–264 VAC bands to LRS-75. The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Match the selected DC version to every connected input, then include simultaneous demand and startup transients before energising the equipment. The planning image is a representative LRS-series example, not an exact-model wiring diagram.

LRS-350 manual-selector planning example; use LRS-75 input bands, selection instructions and output options, not the example labels.


Keep fan and ventilation openings unobstructed inside a cabinet selected for the actual environment. Arrows show conceptual airspace, not a measured airflow path.

LRS-75 enclosure and service-space planning

The specified overall dimensions are 99 × 97 × 30 mm. The listed product weight is 0.3 kg. Reserve additional space for terminal access, conductor routing and the host equipment's airflow; the case outline is not a clearance allowance.

LRS-series cabinet-space concept; the exact case, cooling method and mounting are defined by this model's own technical data.


The −20°C to +70°C working range does not establish full output at every temperature. Use the selected version’s load and thermal limits.

Temperature and duty-cycle assessment for LRS-75

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. Measure the temperature at the installed supply and review the longest expected duty cycle. Keep vents unobstructed; do not substitute room temperature for the operating temperature inside the equipment.

LRS-350 temperature-planning example, not a measured derating curve or a replacement for LRS-75 operating limits.


Functional power-planning illustration only. Have qualified personnel select protection, follow terminal markings and verify safe isolation before work.

LRS-75 fault recovery and protected installation

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. Have a qualified installer check terminal identification, protective earthing and branch protection for the actual assembly. Coordinate restart behaviour with the equipment controls rather than treating supply recovery as a safety function.

Functional power-planning illustration only; follow the exact model's terminal identification and qualified installation instructions.



Application Industries

AI LRS-series planning and application illustrations; equipment scenes are not customer-installation records or exact-model dimensional or wiring evidence.


AI illustration of an illuminated retail lightbox and storefront at blue hour.

Retail sign-control and LED-module branches

A retail sign can be divided into a verified control branch and independently checked illumination branches. LRS-75 is a conditional source for the selected compatible DC group, not proof that the whole sign fits. Include the longest display duty cycle and the protected compartment temperature.

The LRS-75-24 column lists 24 V and an output-current range of 0–3.2 A.

AI application concept — retail signage, not an installation record for this product.


AI illustration of complete self-service parcel lockers and a central pickup screen in a bright indoor lobby.

Parcel-terminal interface electronics

For a parcel terminal with several doors, assess LRS-75 against the planned release sequence, sensing and controller demand. Use separately protected branches and verify the peak combination rather than multiplying an average lock current. The display and any backup system remain separate design decisions.

The LRS-75-12 column lists 12 V and an output-current range of 0–6 A.

AI application concept — parcel-terminal electronics, not an installation record for this product.


AI illustration of a complete guarded automatic carton-packing machine on a production floor.

Carton-packaging auxiliary electronics

At an automatic packing station, consider LRS-75 for compatible registration sensors, panel indicators and the machine-interface electronics. Define what remains energised during a process stop. The motors, heaters and safety-related circuits are not part of this auxiliary power role.

The LRS-75-15 column lists 15 V and an output-current range of 0–5 A.

AI application concept — carton-packaging auxiliary electronics, not a complete-machine power claim.


AI illustration of an electronics inspection workbench with a supported PCB fixture and optical inspection equipment.

Electronics-fixture auxiliary interfaces

A PCB assembly fixture can separate relay and controller power from its measurement circuitry. An LRS-75 version may feed the compatible auxiliary side after input and transient checks. Any lower-voltage electronics need appropriately qualified conversion; the image is not evidence of a programmable test output.

The LRS-75-48 column lists 48 V and an output-current range of 0–1.6 A.

AI application concept — electronics-fixture interfaces; no measurement-performance or installed-model claim.



Preguntas frecuentes

Which output-voltage models does the LRS-75 provide?

The LRS-75 offers separate 12 V, 15 V, 24 V and 48 V models: LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. Each model is a single-output choice; the alternatives are not simultaneous rails on the same unit.

How are the LRS-75 current ranges and series-power statement distinguished?

The printed output-current ranges are 0–6 A, 0–5 A, 0–3.2 A and 0–1.6 A for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. The series summary states "Single output: power 75W". The sheet gives no separate continuous-wattage row for each output variant; the summary power and the printed current endpoints must remain separate selection facts. Continuous-load acceptance must keep both source statements in view, with transient demand and thermal conditions reviewed for the actual design.

Which input range is specified for the LRS-75?

The input specification lists 85–264 VAC / 120–373 VDC and 47–63 Hz. The input range does not document a selector switch or an automatic range-switching mechanism. Confirm source behavior and input wiring from the applicable product documentation before integration.

What body size and weight are listed for the LRS-75?

The specified overall dimensions are 99 × 97 × 30 mm. The listed product weight is 0.3 kg. Overall dimensions support space planning, not mounting-hole, terminal-clearance or enclosure-access dimensions.

How does LRS-75 efficiency vary by output model?

The listed efficiencies are 87%, 87%, 88% and 89% for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. Use the figure for the selected output model, then assess losses under the actual equipment load.

Which ripple-and-noise figures are listed for the LRS-75?

The listed ripple-and-noise values are 120 mVp-p, 120 mVp-p, 150 mVp-p and 200 mVp-p for LRS-75-12, LRS-75-15, LRS-75-24 and LRS-75-48, respectively. The sheet does not give the efficiency or ripple measurement conditions, so these figures are not a complete equipment-level performance guarantee. A sensitive camera or measurement interface needs a load-side noise check with the actual cabling and other loads operating.

What do the LRS-75 line- and load-regulation figures describe?

Line regulation and load regulation are each listed as ±0.5%. These are separate line- and load-regulation figures, not an additional overall output-voltage tolerance. Cable drop and load-step response remain separate parts of the connected-equipment voltage budget.

What does the LRS-75 DC-voltage adjustment specification establish?

The DC-voltage adjustment range is listed as ±10%. The adjustment specification does not establish dimming, programmability or a constant-current operating mode. The connected equipment input window limits the permissible final setting.

How does LRS-75 overload protection respond?

Overload protection cuts off the output at 110%–150% and provides automatic recovery. The sheet also lists overcurrent protection and short-circuit protection. The overload threshold is not an extra continuous-load allowance, and recovery is not a machine safety or redundant-power function.

Which startup figures are listed for the LRS-75?

The listed cold-start current is 50 A at 230 VAC. The setup/rise row gives 1000 ms and 30 ms at 230 VAC, and 2000 ms and 30 ms at 115 VAC. The row includes hold-up in its heading but prints no separate hold-up duration or full-load test condition. Upstream protection, simultaneous energization and electronics-ready sequencing require system-level assessment.

What working-temperature boundary is documented for the LRS-75?

The specified working-temperature range is -20°C to +70°C. Use the temperature/load curve displayed with the model-specific technical data under its stated conditions. The operating interval alone is not a promise of full output at every temperature. Assess mounting, airflow, actual load and temperature in the finished equipment; the reference curve does not expand the WEHO model's stated operating or output ratings.

Which insulation test figures are listed for the LRS-75?

The withstand figures are 1.5 kV from input to output, 1.5 kV from input to FG and 0.5 kV from output to FG, each for 1 minute. Isolation resistance is listed as 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. These test figures do not establish an ingress rating or product certification. Assembly earthing, protective barriers and end-equipment conformity need their own verification.

¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?

Impulsa tu negocio con productos de suministro de energía de calidad WEHO.

Pregúntale a un experto
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.