Match the supply to the load
Check the incoming supply against 95–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.
The LRS-500 is a 500W-class single-output enclosed power supply with a fan-equipped 215 × 115 × 50 mm body. Choose the 12V, 24V, 36V or 48V version by the required DC bus and listed current range. Select 95–132VAC or 180–264VAC using the input-range switch; the DC input range is 254–370VDC and the AC frequency range is 47–63Hz. Efficiency varies by output version from 82% to 88%. The working temperature range is -10°C to +50°C; confirm permissible loading for the installation.
यदि आपके कोई प्रश्न हैं, तो कृपया हमसे संपर्क करने में संकोच न करें ईमेल: [email protected] हमारे पेशेवर आपको यथाशीघ्र जवाब देंगे।.
Single-output AC–DC supply with switch-selectable AC input.
In the inquiry form, enter model LRS-500-12LRS-500-24LRS-500-36LRS-500-48 with your requirements.
| Parameter | LRS-500-12 | LRS-500-24 | LRS-500-36 | LRS-500-48 |
|---|---|---|---|---|
| DC output voltage and current | 12वी 0~40ए | 24V 0~20A | 36V 0~14A | 48V 0~10A |
| इनपुट वोल्टेज रेंज | 95~132VAC/180~264VACby switch 254~370VDC 47~63Hz | |||
| DIMENSIONS | 215×115×50mm | |||
| क्षमता | 82% | 86% | 87% | 88% |
| कार्य तापमान | -10℃~+50℃ | |||
| Ripple & noise | 150mVp-पी | 180mVp-पी | 240mVp-पी | 240mVp-पी |
| रेखा विनियमन | ±0.5% | |||
| लोड विनियमन | ±1% | ±0.5% | ±0.5% | ±0.5% |
| DC voltage adjustment | ±10% | |||
| Inrush current | Cold start current 35A/115VAC 65A/230VAC | |||
| अधिभार संरक्षण | 110%~135%cut off the output,Protection type:Hiccup mode,recovers automatically after fault condition is removed | |||
| ओवरवॉल्टेज संरक्षण | Hiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version. | |||
| Timing (setup / rise / hold-up) | 1500ms,30ms/230VAC 2000ms,50ms/115VAC. No separate hold-up time is specified. | |||
| वोल्टेज का सामना करें | आई/पी-ओ/पी:1.5केवी आई/पी-एफजी:1.5केवी ओ/पी-एफजी:0.5केवी 1 मिनट | |||
| इन्सुलेशन प्रतिरोध | I/P-O/P I/P-FG O/P-FG:100M ओम/500VDC/25℃/70%RH | |||
| वज़न | 1kg | |||
| पैकिंग | 45.5×31.5×26CM/20PCS/20kg | |||
| उत्पादन | मौजूदा | क्षमता | लहर (mVp-p) |
|---|---|---|---|
| 12 V | 0–40 A | 82% | 150 |
| 24 V | 0–20 A | 86% | 180 |
| 36 V | 0–14 A | 87% | 240 |
| 48 V | 0–10 A | 88% | 240 |
| 12 V | ±1% |
|---|---|
| 24 V | ±0.5% |
| 36 V | ±0.5% |
| 48 V | ±0.5% |
| इनपुट वोल्टेज रेंज | 95~132VAC/180~264VACby switch 254~370VDC 47~63Hz |
|---|---|
| DIMENSIONS | 215×115×50mm |
| कार्य तापमान | -10℃~+50℃ |
| रेखा विनियमन | ±0.5% |
| DC voltage adjustment | ±10% |
| Inrush current | Cold start current 35A/115VAC 65A/230VAC |
| अधिभार संरक्षण | 110%~135%cut off the output,Protection type:Hiccup mode,recovers automatically after fault condition is removed |
| ओवरवॉल्टेज संरक्षण | Hiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version. |
| Timing (setup / rise / hold-up) | 1500ms,30ms/230VAC 2000ms,50ms/115VAC. No separate hold-up time is specified. |
| वोल्टेज का सामना करें | आई/पी-ओ/पी:1.5केवी आई/पी-एफजी:1.5केवी ओ/पी-एफजी:0.5केवी 1 मिनट |
| इन्सुलेशन प्रतिरोध | I/P-O/P I/P-FG O/P-FG:100M ओम/500VDC/25℃/70%RH |
| वज़न | 1kg |
| पैकिंग | 45.5×31.5×26CM/20PCS/20kg |
215 × 115 × 50 mm (L × W × H)
Body width: 115 mm. Width including mounting ears: 135 mm. Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face. Body dimensions and mounting-hole spacing are separate references.
A load-derating curve is not available here for LRS-500. Confirm the permissible load at your input voltage, mounting position and enclosure temperature before sizing the supply.
For a 24 V control rail, the LRS-500-24 has a listed output range of 0–20 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. For a switched-input cabinet, check the low AC band carefully: it begins at 95 V, not 90 V. Allow for the 50 mm body height and verify load capability at the intended cabinet temperature.
The representative photograph is for identification. Confirm the nameplate on the ordered unit against its output-current specification.
| विशेषता | What to check |
|---|---|
| Output trim | Use the listed ±10% adjustment only within the load’s input limits. |
| Enclosure fit | Confirm the mounting dimensions and allow room for wiring bends, airflow and terminal access. |
| Overload recovery | The output recovers after the overload condition is removed. Check how the equipment restarts. |

Check the incoming supply against 95–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.

Confirm the body, mounting-hole positions and terminal access against the drawing before laying out the panel.

The listed working range is -10 to +50 °C. Measure the air near the installed supply under sustained load. Confirm the permitted load at that temperature with WEHO.

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.
Size the supply for the auxiliary electronics, not for the whole machine.

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.
24 V option: LRS-500-24 · listed current 0–20 A.

Size the rail for sensors and the operator interface. Account separately for lock pickup current.
12 V option: LRS-500-12 · listed current 0–40 A.

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.
24 V option: LRS-500-24 · listed current 0–20 A.

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.
12 V option: LRS-500-12 · listed current 0–40 A.
AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.
Choose one nominal output: 12 V, 24 V, 36 V, 48 V. Each voltage is a separate model.
The listed AC input is 95–132 V AC / 180–264 V AC (by switch); the DC input is 254–370 V DC. The gap between the two AC bands is not part of the specified input range.
LRS-500-24 is listed at 0–20 A. Check the current at startup as well as in steady operation.
The datasheet gives output current by voltage. Use the selected model’s current range and application conditions rather than treating the series name as a continuous rating for every version.
The working range is -10 to +50 °C. Ask WEHO for a load limit at the intended input voltage and installed temperature; do not assume full load across the range.
The listed body measures 215 × 115 × 50 mm. Check the drawing for mounting dimensions and allow additional room for wiring and airflow.
The cold-start input current is 35 A at 115 V AC, 65 A at 230 V AC. This is an input-side event, not the current available to the DC load.
Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.



WEHO गुणवत्ता वाले बिजली आपूर्ति उत्पादों के साथ अपने व्यवसाय को बढ़ावा दें।.
किसी विशेषज्ञ से पूछें