LRS-500 Enclosed Switching Power Supply

The LRS-500 is a 500W-class single-output enclosed power supply with a fan-equipped 215 × 115 × 50 mm body. Choose the 12V, 24V, 36V or 48V version by the required DC bus and listed current range. Select 95–132VAC or 180–264VAC using the input-range switch; the DC input range is 254–370VDC and the AC frequency range is 47–63Hz. Efficiency varies by output version from 82% to 88%. The working temperature range is -10°C to +50°C; confirm permissible loading for the installation.

หากคุณมีคำถามใด ๆ โปรดอย่าลังเลที่จะติดต่อเราได้ที่ อีเมล: [email protected] ผู้เชี่ยวชาญของเราจะตอบกลับคุณโดยเร็วที่สุด.

LRS-500 representative shown

LRS-500 Enclosed Switching Power Supply

Single-output AC–DC supply with switch-selectable AC input.

แรงดันขาออก
แบบอย่าง
LRS-500-12LRS-500-24LRS-500-36LRS-500-48
DC output
12 V · 0–40 A24 V · 0–20 A36 V · 0–14 A48 V · 0–10 A
อินพุตไฟฟ้ากระแสสลับ
95–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
ประสิทธิภาพ
82%86%87%88%
Dimensions (L × W × H)
215 × 115 × 50 mm

In the inquiry form, enter model LRS-500-12LRS-500-24LRS-500-36LRS-500-48 with your requirements.

Specifications & models

พารามิเตอร์LRS-500-12LRS-500-24LRS-500-36LRS-500-48
DC output voltage and current12V 0~40A24V 0~20A36V 0~14A48V 0~10A
ช่วงแรงดันไฟฟ้าขาเข้า95~132VAC/180~264VACby switch 254~370VDC 47~63Hz
ขนาด215×115×50มม
ประสิทธิภาพ82%86%87%88%
อุณหภูมิในการทำงาน-10°C~+50°C
Ripple & noise150mVp-P180mVp-P240mVp-P240mVp-P
การควบคุมสาย±0.5%
การควบคุมโหลด±1%±0.5%±0.5%±0.5%
DC voltage adjustment±10%
การไหลเข้าปัจจุบันCold start current 35A/115VAC 65A/230VAC
การป้องกันการโอเวอร์โหลด110%~135%cut off the output,Protection type:Hiccup mode,recovers automatically after fault condition is removed
การป้องกันแรงดันไฟฟ้าเกินHiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version.
Timing (setup / rise / hold-up)1500ms,30ms/230VAC 2000ms,50ms/115VAC. No separate hold-up time is specified.
ทนต่อแรงดันไฟฟ้าI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1 นาที
ความต้านทานของฉนวนI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
น้ำหนัก1kg
การบรรจุ45.5×31.5×26CM/20PCS/20kg
Output options
เอาท์พุตปัจจุบันประสิทธิภาพระลอกคลื่น (mVp-p)
12 V0–40 A82%150
24 V0–20 A86%180
36 V0–14 A87%240
48 V0–10 A88%240
การควบคุมโหลด
12 V±1%
24 V±0.5%
36 V±0.5%
48 V±0.5%
Common specifications
ช่วงแรงดันไฟฟ้าขาเข้า95~132VAC/180~264VACby switch 254~370VDC 47~63Hz
ขนาด215×115×50มม
อุณหภูมิในการทำงาน-10°C~+50°C
การควบคุมสาย±0.5%
DC voltage adjustment±10%
การไหลเข้าปัจจุบันCold start current 35A/115VAC 65A/230VAC
การป้องกันการโอเวอร์โหลด110%~135%cut off the output,Protection type:Hiccup mode,recovers automatically after fault condition is removed
การป้องกันแรงดันไฟฟ้าเกินHiccup mode with automatic recovery after the fault condition is removed. Confirm the approved overvoltage threshold for the ordered version.
Timing (setup / rise / hold-up)1500ms,30ms/230VAC 2000ms,50ms/115VAC. No separate hold-up time is specified.
ทนต่อแรงดันไฟฟ้าI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1 นาที
ความต้านทานของฉนวนI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
น้ำหนัก1kg
การบรรจุ45.5×31.5×26CM/20PCS/20kg

Dimensions & derating

Mechanical dimensions

215 × 115 × 50 mm (L × W × H)

Wide face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
Narrow face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Body width: 115 mm. Width including mounting ears: 135 mm. Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face. Body dimensions and mounting-hole spacing are separate references.

Load derating

A load-derating curve is not available here for LRS-500. Confirm the permissible load at your input voltage, mounting position and enclosure temperature before sizing the supply.

Product overview

For a 24 V control rail, the LRS-500-24 has a listed output range of 0–20 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. For a switched-input cabinet, check the low AC band carefully: it begins at 95 V, not 90 V. Allow for the 50 mm body height and verify load capability at the intended cabinet temperature.

The representative photograph is for identification. Confirm the nameplate on the ordered unit against its output-current specification.

Design features

คุณสมบัติWhat to check
Output trimUse the listed ±10% adjustment only within the load’s input limits.
Enclosure fitConfirm the mounting dimensions and allow room for wiring bends, airflow and terminal access.
Overload recoveryThe output recovers after the overload condition is removed. Check how the equipment restarts.

Installation & applications

Installation checks

A closed instrument, a clipboard and a handheld meter on a workshop bench.

Match the supply to the load

Check the incoming supply against 95–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.

A closed, vented equipment cabinet beside a clear service aisle and a wall grille.

Leave room for service

Confirm the body, mounting-hole positions and terminal access against the drawing before laying out the panel.

An environmental test chamber with a lit observation window and an instrument cart.

Check the installed temperature

The listed working range is -10 to +50 °C. Measure the air near the installed supply under sustained load. Confirm the permitted load at that temperature with WEHO.

An empty roller conveyor behind a yellow barrier, with a closed equipment cabinet beside it.

Plan for power returning

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

A freestanding illuminated lightbox outside a glass-fronted shop at dusk.

Retail signage

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.

24 V option: LRS-500-24 · listed current 0–20 A.

Indoor parcel lockers with a touchscreen and a parcel in an open compartment.

Parcel lockers

Size the rail for sensors and the operator interface. Account separately for lock pickup current.

12 V option: LRS-500-12 · listed current 0–40 A.

A carton passes a bracket-mounted photoelectric sensor with an amber status light on a conveyor belt.

Carton packaging

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.

24 V option: LRS-500-24 · listed current 0–20 A.

A circuit board clamped below an inspection camera, with an enlarged board view on a monitor.

Electronics test fixtures

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.

12 V option: LRS-500-12 · listed current 0–40 A.

AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.

Frequently asked questions

Single-output versionsOutput voltage and current range12 V0–40 A24 V0–20 A36 V0–14 A48 V0–10 A
Choose one DC output per supply.
Which output voltages are available?

Choose one nominal output: 12 V, 24 V, 36 V, 48 V. Each voltage is a separate model.

Which input voltage should I specify?

The listed AC input is 95–132 V AC / 180–264 V AC (by switch); the DC input is 254–370 V DC. The gap between the two AC bands is not part of the specified input range.

How much current is listed for the 24 V model?

LRS-500-24 is listed at 0–20 A. Check the current at startup as well as in steady operation.

What does the series power designation mean?

The datasheet gives output current by voltage. Use the selected model’s current range and application conditions rather than treating the series name as a continuous rating for every version.

What temperature range can I use?

The working range is -10 to +50 °C. Ask WEHO for a load limit at the intended input voltage and installed temperature; do not assume full load across the range.

How do I check the mounting space?

The listed body measures 215 × 115 × 50 mm. Check the drawing for mounting dimensions and allow additional room for wiring and airflow.

What inrush current is listed?

The cold-start input current is 35 A at 115 V AC, 65 A at 230 V AC. This is an input-side event, not the current available to the DC load.

What should I include in my quote request?

Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.

LRS-500 datasheet

Close
Download PDF
LRS-500 datasheet, page 1 of 2: Electrical specifications.
LRS-500 datasheet, page 2 of 2: Mechanical drawing and terminal assignments.

LRS-500 product photograph

LRS-500 representative product photograph

Wide face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Narrow face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.