
The 96 ×48 mm front size of a TX4-W is not the size of the panel opening. The current product table and TX4 manual give a 92 ×45 mm cutout for this horizontal form. A retrofit must also allow the rear body, retention arrangement, terminals and maintenance access; matching the front outline alone is insufficient.
This guide helps an OEM panel designer decide whether a proposed existing opening and enclosure layout can proceed to a mechanical trial. It keeps a documented dimension separate from an unverified installation assumption.
List three different envelopes on the drawing
IL WEHO TX4-W page identifies the horizontal 96 ×48 mm front and 92 ×45 mm opening. The TX4 230808EN manual repeats those opening dimensions in its size table. They describe different parts of the installation: the visible front covers the panel; the body passes through the opening; rear connections occupy additional space inside.
Draw the front footprint, actual cutout and rear service envelope as separate layers. Do not rotate a tall TX4-H outline and assume the retention or terminal arrangement is unchanged. The W size is a distinct documented form, and the applicable complete model and revision must remain attached to the drawing.
Measure the existing opening before cutting metal
Record width and height at multiple positions, corner geometry, burrs, panel thickness and the location of adjacent controls. The nominal 92 ×45 mm statement is not a complete tolerance specification for every fabrication process. Obtain the applicable installation drawing and panel-thickness/retention requirements before releasing the cutout.
For a hypothetical existing opening of 90.0 ×44.0 mm, reaching the nominal 92 ×45 mm sizes requires 2.0 mm additional total width and 1.0 mm additional total height. If centered perfectly, that is 1.0 mm per vertical side and 0.5 mm per horizontal side. This simple arithmetic does not establish acceptable edge tolerances or authorize field machining near live equipment.
Front overlap is a geometric check, not a seal rating
For the listed 96 ×48 mm front over a nominal 92 ×45 mm opening, centered arithmetic overlap is (96−92)/2=2 mm on each left/right side and (48−45)/2=1.5 mm at top/bottom. An off-center or oversize opening consumes that coverage unevenly.
Do not infer sealing, structural retention or a permissible hole tolerance from those overlap numbers. A gasket and clamp arrangement, if applicable, must be supported by the exact model’s documentation. The front photograph can identify the W layout but cannot prove an unseen clip is engaged.
Resolve the depth source conflict before mechanical release
The TX4 product-page features state 75 mm depth, while the TX4 manual dimension table shows D=50 mm for the W form and the broader catalog also describes 50 mm depth. These inspected sources do not establish which revision or dimension convention accounts for the difference. Do not choose 50 mm because it fits the enclosure better, or add 25 mm to an invented connector dimension and declare the conflict solved.
Request the current exact-model outline and identify the dimension reference surfaces. Then add the documented terminal projection, connector access, wire bend and maintenance withdrawal needs for the actual configuration. A body-depth number is not the full required distance to a closed rear panel or cable duct.
Check the enclosure in operating and service positions
Model the door closed, open and at the intended service angle. Internal conductors should not pull terminals as the door moves, cross sharp edges or block adjacent devices. Reserve space for the actual terminal access and for removal using the approved method. Do not treat an empty enclosure rendering as proof of serviceability after all wiring is installed.
Check whether adjacent controls or latches obstruct the bezel or retention access. The manual includes panel spacing information, which should be read with its figure and applicable revision rather than converted into a universal gap from a text extraction alone. Use a physical sample or accurately documented model for the final fit comparison.
Release a drawing that the next fabricator can repeat

Retain the exact TX4-W code, approved outline revision, measured panel condition and verified opening/retention method. Include any adapter plate as its own engineered part with defined material and attachment. Do not hide an oversize hole behind a decorative product frame and describe it as the original installation.
The fit record should state whether only the front appearance, a sample installation or the complete wired enclosure has been checked. Those are different levels of evidence. Final release requires the actual retention and service envelope to be verified, including the unresolved depth question.
Send WEHO the full TX4-W requirement, existing cutout measurements, panel thickness, enclosure drawing and rear-space limit. Ask for the current matching outline and installation requirements before freezing the retrofit drawing.
TX4-W retrofit fit record
| Front | Footprint | Coverage | Alignment |
|---|---|---|---|
| Cutout | Width/height/corners | Applicable tolerance | Fabrication result |
| Rear | Verified body reference | Terminal/wire/service envelope | Closed/open door |
| Retention | Documented method | Sample fit | Release |
Blank project worksheet. Enter verified project data; example calculations above are not measurements.



