| Especificação | S-800-12 | S-800-24 | S-800-36 | S-800-48 |
| Tensão de saída CC, corrente | 12V 0 ~ 66A | 24V 0 ~ 33A | 36V 0 ~ 22A | 48V 0 ~ 17A |
| Onda e ruído | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p |
| Estabilidade do fio de entrada | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Estabilidade de carga | ±0,5% | ±0,5% | ±0,5% | ±0,5% |
| Eficiência | 80% | 85% | 85% | 87% |
| Faixa ajustável para tensão DC | ±10% | ±10% | ±10% | ±10% |
| Faixa de tensão de entrada | 100 ~ 132VAC/200 ~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz | |||
| Corrente de impacto | Corrente de partida a frio 45A/230VAC | |||
| Proteção de sobrecarga | 105% ~ 135% cut off the output, automatic recovery | |||
| Outra proteção | Not specified in this datasheet (overvoltage threshold and short-circuit recovery mode are not stated). | |||
| Configure, levante, mantenha o tempo de atividade | 2000ms, 50ms, 20ms/230VAC at full load | |||
| Suportar tensão | I/P-O/P: 1.5kV; I/P-FG: 1.5kV; O/P-FG: 0.5kV; 1 minute | |||
| Resistência de isolamento | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ | |||
| Temperatura de trabalho | -10°C ~ +50°C | |||
| Dimensão | 291 × 132 × 68mm | |||
| Peso | 2.65kg | |||
| Embalagem | 37.5 × 31 × 25.5CM/6PCS/16kg | |||
S-800W series normal single switching power supply
WEHO S-800 is a single-output switching power supply with separate 12V, 24V, 36V and 48V variants. Its separately specified output options help equipment builders shortlist a supply for compatible recipe interfaces and production-status electronics without treating the machine drive as the load. Share the exact electronic load, input supply and enclosure conditions when requesting variant selection.
Se você tiver alguma dúvida, não hesite em nos contatar em E-mail: [email protected]
- Descrição
Why Choose S-800
Select the required output, not just the family label
The S-800-12 column lists 12V with a 0 ~ 66A current range. This preserves the distinction between the family power label and the low-voltage column when sizing a control-electronics branch. The other suffixes are separate output choices, not simultaneous rails.
Plan selectable input at the equipment site
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The explicit input bands help procurement distinguish a switch-selected unit from an automatically ranging supply. Confirm the delivered selector instructions and site supply before energizing; the printed DC range is not a DC wiring procedure.
Reserve an identifiable equipment envelope
The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. These entries support an initial cabinet-envelope and handling review. Allow separate room for studs, cable bends, ventilation and servicing; the body size alone does not establish mounting fit or terminal clearance.
Evaluate adjustment against the real electronics tolerance
The DC-voltage adjustment entry is ±10% for every listed output. This provides a defined adjustment entry for a matched rail, but the connected boards must tolerate the final setting and transients. Adjustment is not an additional current rating or a substitute for load qualification.
S-800 Features and Selection Benefits
Separate line and load stability entries
Inlet-wire stability and load stability are each ±0.5% for every listed output. These figures help compare steady-state regulation requirements. They do not describe output accuracy over every temperature or dynamic step-load performance.
Output-specific wave-and-noise figures
The wave-and-noise entries are S-800-12: 150mVp-p; S-800-24: 180mVp-p; S-800-36: 180mVp-p; S-800-48: 240mVp-p. Compare the selected column with the electronics noise allowance. Sensitive measurement or communication circuits still need application-level evaluation; no unprinted bandwidth or test fixture is assumed.
Efficiency values tied to each suffix
The efficiency entries are S-800-12: 80%; S-800-24: 85%; S-800-36: 85%; S-800-48: 87%. Use the relevant entry for a preliminary power-loss discussion, not as a measured result for the finished cabinet. The actual input, load, duty cycle and internal temperature govern the thermal review.
A stated overload response, without extra protection promises
Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. Automatic recovery must be considered in the machine restart strategy; it does not qualify the supply as a protective control or eliminate independent branch protection.
Typical S-800 Service Conditions
Keep cutting dust out of the electrical bay
The printed working-temperature range is -10°C ~ +50°C. For a paper guillotine cutting line, assess compatible job-selection and status electronics in a separately protected compartment. Check the local hot spot over repeated cutting cycles, keep paper dust away from the supply and preserve ventilation. Blade and clamp power and protective controls remain separate.
Check the selector before a labelling-line move
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. A rotary bottle-label applicator may be transferred between sites with different incoming supplies. Verify the actual AC band and selector setting before powering its compatible recipe and communication modules. Keep label adhesive and cleaning liquids outside the electrical bay; turret and servo circuits need separate selection.
Budget simultaneous electronic restarts
The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. At a mattress quilting gantry, assess the input branch when the pattern-transfer and job-display electronics restart together with other cabinet equipment. Use the printed cold-start condition only for its stated input, verify the intended site separately and keep the sewing-head and gantry drives outside the proposed DC duty.
Design an orderly return after power interruption
Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. For a timber finger-jointing cell, validate the recipe and batch-status electronics through interrupted input and automatic overload recovery. Do not use the timing figures as a guarantee of uninterrupted data or a safe machine restart. Separate timber dust and glue handling from the electrical bay; cutter, feed and glue-pump power remain independent.
Potential S-800 Equipment Applications
Corrugated-carton slotter
A corrugated-carton slotter may evaluate a qualified S-800 variant for compatible 24V-input order-interface and sheet-count communication boards, not feed drives or cutting mechanisms. Verify the order-interface voltage, count-data retention, ripple allowance and branch loading through feed-stop cycles. The cutting train and sheet transport remain separately powered. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Textile fabric spreading machine
A textile fabric spreading machine may evaluate a qualified S-800 variant for compatible 12V-input pattern-file and operator-display electronics, not carriage drives or fabric tension actuators. Match the display and file-interface input to the selected suffix, then check wiring voltage drop and repeated start demand along the long equipment layout. Fabric motion and tension remain independent. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Injection-moulding workcell
An injection-moulding workcell may evaluate a qualified S-800 variant for compatible 24V-input production-record and non-safety display electronics, not injection drives, barrel heaters or hydraulic pumps. Check the display branch through moulding cycles and cabinet heat soak; a compatible nominal voltage does not establish process or protective-control suitability. No heater, injection or hydraulic power is assigned. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
Automatic screwdriving assembly tower
An automatic screwdriving assembly tower may evaluate a qualified S-800 variant for compatible 24V-input recipe-selection and traceability modules, not screwdriver motors, fixture actuators or protective circuits. Qualify module voltage, transient demand and the feeder-area enclosure before selecting the suffix. Traceability functionality does not establish screw torque, fixture motion or machine safety. This is a proposed equipment role, not evidence of a customer installation; exact suffix, load, wiring and thermal conditions require engineering.
S-800 Technical FAQs
Which S-800 variants are printed, and what does its power-class label mean?
S-800-12: 12V, 0 ~ 66A; S-800-24: 24V, 0 ~ 33A; S-800-36: 36V, 0 ~ 22A; S-800-48: 48V, 0 ~ 17A. The summary uses the 800W single-output power-class label. A printed current range is not independently approved rated continuous current. Do not infer a minimum-load rule, a full-temperature continuous power rating or parallel capability from the range or from voltage multiplied by its upper bound.
How is the S-800 input selected?
AC input is 100 ~ 132VAC or 200 ~ 264VAC by switch; the input row also lists 254 ~ 370VDC and 47 ~ 63Hz. The AC bands are not one uninterrupted automatic-ranging input. Verify selector position with power isolated using the delivered instructions. Confirm any intended DC-input connection and polarity separately; the listed DC range does not establish those instructions.
What cold-start input condition is stated for S-800?
The only printed cold-start entry is 45A at 230VAC; no 115VAC cold-start value is given. Use that input association for upstream switch-on assessment and check aggregate inrush with other cabinet loads. It is not the normal input current, a fuse recommendation or proof of behavior on the other AC band.
What setup, rise and hold-up conditions are stated for S-800?
Setup, rise and hold-up times are 2000ms, 50ms and 20ms, respectively, at 230VAC at full load. The three values have distinct functions and belong to that printed input/full-load condition. They do not establish stored-data retention, uninterrupted process operation or full-temperature full-load duty; verify the equipment response to loss and return of input.
How do S-800 wave-and-noise entries vary by output?
S-800-12: 150mVp-p; S-800-24: 180mVp-p; S-800-36: 180mVp-p; S-800-48: 240mVp-p. Assess sensitive electronic loads against the figures for the selected model. The page does not give a bandwidth, probe arrangement or separate dynamic-noise test condition; qualify the actual electronics and routing rather than inventing those conditions.
How should S-800 stability and adjustment figures be used?
Inlet-wire stability and load stability are each ±0.5% for every listed output. The DC-voltage adjustment entry is ±10% for every listed output. Line stability, load stability and adjustment describe different attributes. Neither the stability values nor the available adjustment proves an arbitrary electronics tolerance, output accuracy over temperature or permissible extra current after voltage adjustment.
Which efficiency figures belong to the S-800 suffixes?
S-800-12: 80%; S-800-24: 85%; S-800-36: 85%; S-800-48: 87%. These are output-column entries, not measured cabinet efficiency under the proposed load. Confirm the operating input, output, loading and thermal arrangement before using the figure in a final thermal or energy calculation.
What protection response is specified for S-800?
Overload protection is listed at 105% ~ 135% with output cutoff and automatic recovery. No separate overvoltage threshold or short-circuit recovery mode is specified on this sheet. The sheet does not explicitly define the percentage reference or a separate fault-current duty. Do not treat automatic recovery as a safety function, permission for unattended restart or a replacement for correctly engineered branch protection.
What environment does the S-800 sheet describe?
The printed working-temperature range is -10°C ~ +50°C. Storage temperature, working humidity and storage humidity are not specified on this sheet. Confirm the enclosure hot spot, ventilation, contamination and actual electronic load. The working-temperature entry is not a derating curve or approval for full load across that range, and it supplies no ingress rating or process-area approval.
What mechanical and shipping entries are listed for S-800?
The listed body dimensions are 291 × 132 × 68mm and the listed weight is 2.65kg. Packing is listed as 37.5 × 31 × 25.5CM/6PCS/16kg. The drawing separately marks body and hole references; do not combine them into an unprinted overall cable or stud clearance. Confirm the delivered unit, mounting details and current shipping configuration before final enclosure or logistics design.
What can be taken from the S-800 terminal drawing?
The front drawing labels the two output studs POS(+) and NEG(-), with a 2-M6 callout; the input view labels FG, N and L beside AC INPUT. No numbered pin legend is printed. The drawing also marks the LED and voltage-adjustment point. The input-strip view shows five screw-like circular positions, but only the inner FG, N and L positions are labelled; the two unlabelled end positions are not assigned an electrical function here. Confirm the delivered variant and terminal arrangement before wiring. FG and output signs alone do not establish the system bonding scheme, output-isolation approval or permitted interconnection.
What withstand and isolation entries are printed for S-800?
Withstand entries are I/P-O/P: 1.5kV, I/P-FG: 1.5kV and O/P-FG: 0.5kV for 1minute, without a printed AC/DC test qualifier. Isolation resistance is listed as 500VDC/100MΩ for I/P-O/P, I/P-FG and O/P-FG. No AC/DC test-voltage qualifier is stated for these kV entries. These entries are not a certificate, an instruction to perform a field high-voltage test, a touch-safety classification or approval of an equipment grounding arrangement.
Quais são os melhores produtos de fonte de alimentação para o seu negócio?
Impulsione o seu negócio com produtos de fonte de alimentação de qualidade WEHO.
Pergunte a um especialista