Reserve the rail position
Compare the 55.5 × 125.2 × 100 mm body with the available space. The sheet identifies a DIN rail mount but does not specify the rail profile. Verify the clip and rail before installation. Leave room to reach the terminals.
WeHo’s DR-75 series is a single output Din rail type power supply that can be installed on TS-35/7.5 or 15 DIN rails.
Adopting the full range 86-264VAC input, the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48VDR-75 is a reliable switching power supply with high-quality material, durability, and safety to use.DR-75 has a little higher price to perform power supply solutions for various industrial applications.หากคุณมีคำถามใด ๆ โปรดอย่าลังเลที่จะติดต่อเราได้ที่ อีเมล: [email protected]
Compare four DC outputs in a 55.5 × 125.2 × 100 mm rail enclosure. The 12 V version has a 0–6.3 A range; the 48 V version has a 0–1.6 A range.
| พารามิเตอร์ | DR-75-12 | DR-75-15 | DR-75-24 | DR-75-48 |
|---|---|---|---|---|
| DC output voltage and current | 12 V · 0–6.3 A | 15 V · 0–5 A | 24 V · 0–3.2 A | 48 V · 0–1.6 A |
| ประสิทธิภาพ | 76% | 80% | 80% | 81% |
| ระลอกคลื่นและเสียงรบกวน | 100 mV p-p | 150 mV p-p | 150 mV p-p | 240 mV p-p |
| การควบคุมสาย | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| การควบคุมโหลด | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| DC voltage adjustment | ±10% | ±10% | ±10% | ±10% |
| อินพุตไฟฟ้ากระแสสลับ | 85–264 VAC | |||
| DC input | 120–370 VDC | |||
| ขนาด | 55.5 × 125.2 × 100 mm | |||
| AC input frequency | 47–63 Hz | |||
| Cold-start inrush | 20 A at 115 VAC; 40 A at 230 VAC | |||
| การป้องกันการโอเวอร์โหลด | 105–150%; output cuts off and recovers automatically. | |||
| การป้องกันแรงดันไฟฟ้าเกิน | 121–142%; output shuts down. Cycle input power to recover. | |||
| Setup / rise / hold-up | 1000 / 60 / 60 ms at 230 VAC, full load | |||
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. | |||
| ความต้านทานของฉนวน | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. | |||
| อุณหภูมิในการทำงาน | −10 °C to +50 °C | |||
| Mounting rail | DIN rail; profile not specified. | |||
| Unit weight | 0.55 kg | |||
| การบรรจุ | 42 × 25 × 24 cm / 24 pcs / 13.5 kg | |||
| แบบอย่าง | เอาท์พุต | ปัจจุบัน | ประสิทธิภาพ |
|---|---|---|---|
| DR-75-12 | 12 V | 0–6.3 A | 76% |
| DR-75-15 | 15 V | 0–5 A | 80% |
| DR-75-24 | 24 V | 0–3.2 A | 80% |
| DR-75-48 | 48 V | 0–1.6 A | 81% |
| ระลอกคลื่นและเสียงรบกวน | 100 mV p-p |
|---|---|
| การควบคุมสาย | ±0.5% |
| การควบคุมโหลด | ±0.5% |
| DC voltage adjustment | ±10% |
| ระลอกคลื่นและเสียงรบกวน | 150 mV p-p |
|---|---|
| การควบคุมสาย | ±0.5% |
| การควบคุมโหลด | ±0.5% |
| DC voltage adjustment | ±10% |
| ระลอกคลื่นและเสียงรบกวน | 150 mV p-p |
|---|---|
| การควบคุมสาย | ±0.5% |
| การควบคุมโหลด | ±0.5% |
| DC voltage adjustment | ±10% |
| ระลอกคลื่นและเสียงรบกวน | 240 mV p-p |
|---|---|
| การควบคุมสาย | ±0.5% |
| การควบคุมโหลด | ±0.5% |
| DC voltage adjustment | ±10% |
| อินพุตไฟฟ้ากระแสสลับ | 85–264 VAC |
|---|---|
| DC input | 120–370 VDC |
| ขนาด | 55.5 × 125.2 × 100 mm |
| AC input frequency | 47–63 Hz |
| Cold-start inrush | 20 A at 115 VAC; 40 A at 230 VAC |
| การป้องกันการโอเวอร์โหลด | 105–150%; output cuts off and recovers automatically. |
| การป้องกันแรงดันไฟฟ้าเกิน | 121–142%; output shuts down. Cycle input power to recover. |
| Setup / rise / hold-up | 1000 / 60 / 60 ms at 230 VAC, full load |
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. |
| ความต้านทานของฉนวน | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. |
| อุณหภูมิในการทำงาน | −10 °C to +50 °C |
| Mounting rail | DIN rail; profile not specified. |
| Unit weight | 0.55 kg |
| การบรรจุ | 42 × 25 × 24 cm / 24 pcs / 13.5 kg |
55.5 × 125.2 × 100 mm

Terminal positions and the numbered face as drawn on the manufacturer sheet.

Perforated face from the same mechanical drawing.

Check the enclosure profile and allow additional working space beyond the outline.
Pins 1 and 2: AC input; 3: ground; 4 and 5: −V; 6 and 7: +V. The sheet groups the AC pair; identify L and N from the markings on the unit.
The sheet identifies a DIN rail mount but does not specify the rail profile. Verify the clip and rail before installation.
Do not infer a DC-input polarity assignment from the AC-input legend.
The DR-75 accepts 85–264 VAC or 120–370 VDC. Choose the output suffix to match the load voltage, then check its current, ripple and regulation in the table.
The 12 V version lists 100 mV p-p ripple and noise; the 48 V version lists 240 mV p-p. Use the figure for the branch you intend to power.
| คุณสมบัติ | What to check |
|---|---|
| Order by suffix | DR-75-12 / DR-75-15 / DR-75-24 / DR-75-48 |
| Rail mounting | The sheet identifies a DIN rail mount but does not specify the rail profile. Verify the clip and rail before installation. |
| Overload behaviour | 105–150%; output cuts off and recovers automatically. |
| Output adjustment | ±10% of the selected version’s output voltage. |

Compare the 55.5 × 125.2 × 100 mm body with the available space. The sheet identifies a DIN rail mount but does not specify the rail profile. Verify the clip and rail before installation. Leave room to reach the terminals.

Isolate power and read the full suffix on the unit. The pictured specimen is DR-75-24; a different suffix has a different output.

For DR-75-24, compare the simultaneous running and startup demand with 0–3.2 A. The input inrush is not the available output current.

Cold-start inrush is 20 A at 115 VAC; 40 A at 230 VAC. Check upstream protection for the input voltage and number of supplies starting together.

A shaft-speed sensor can alert the operator when a transfer belt slows. Specify the sensor branch separately from the conveyor motor. For a 24 VDC version, check running and peak current against DR-75-24 (0–3.2 A).
Photo: Anne Burgess · CC BY-SA 2.0 · Resized · WebP
A scale indicator converts load-cell signals into a weight reading. Use the indicator’s specified DC input; do not connect the supply directly to a strain-gauge bridge. For a 24 VDC version, check running and peak current against DR-75-24 (0–3.2 A).
Photo: N509FZ · CC BY-SA 4.0 · Cropped · WebP
A carriage encoder can report lift position as a stacker crane lines up with a rack. The lift drive is a separate load. For a 24 VDC version, check running and peak current against DR-75-24 (0–3.2 A).
Photo: Gilgen Logistics AG · CC BY-SA 4.0 · Resized · WebP
A high-level probe at a loading point can tell the operator when grain reaches the fill mark. Size its transmitter and annunciator, not the auger drive. For a 12 VDC version, check running and peak current against DR-75-12 (0–6.3 A).
Photo: You don't get to know my name You can call me Escobar · CC BY-SA 2.0 · Cropped · WebPThese photographs show application equipment, not verified DR installations or endorsements. Match the downstream component’s DC input and current demand; the supply is not sized here for the whole machine.
No. The model suffix specifies one output voltage. For example, DR-75-12 is the 12 V version. The ±10% trim is not a selector for the other versions.
DR-75-24 is specified at 0–3.2 A. Use the load’s startup requirement as well as its running current.
20 A at 115 VAC; 40 A at 230 VAC. These are cold-start input values, not DC load limits.
The manufacturer specifies 55.5 × 125.2 × 100 mm. The sheet identifies a DIN rail mount but does not specify the rail profile. Verify the clip and rail before installation.
105–150%; output cuts off and recovers automatically.
121–142%; output shuts down. Cycle input power to recover.
Setup, rise and hold-up are 1000, 60 and 60 ms respectively at full load and 230 VAC. Do not assume these times at another input voltage.
Use the selected column instead: DR-75-12 lists 0–6.3 A, while DR-75-48 lists 0–1.6 A. The family heading does not replace a load check.



The photograph shows DR-75-24. Selecting another voltage changes the specifications, not the specimen shown.

DR-75 family exterior: rear enclosure and rail clip. This angle does not identify the output suffix.

DR-75 family exterior: input connector viewed from the terminal end. This angle does not identify the output suffix.

Terminal positions and the numbered face as drawn on the manufacturer sheet.

Perforated face from the same mechanical drawing.

Check the enclosure profile and allow additional working space beyond the outline.
Tell us how many units you need and where they will be delivered.