Blog

imageye imgi 6 Dekor

Constant Current Short-Circuit Protection: A Must-Have in High-Power Adjustable Supplies

A high-power adjustable power supply is different from a regular voltage source. It not only needs to deliver electrical energy,

Capacitive Load Startup: Check Charging Current Before Choosing a Power Supply

A modest running load can still prevent a DC rail from starting. Calculate the capacitor charging demand, include the load

Power Supply Reverse Current: Define Where Returned Energy Goes

A source that delivers a load current is not automatically able to accept current coming back. Define the power path

Standby Power Consumption in OEM Equipment: Build a State-Based AC Energy Budget

A power supply’s no-load input figure is not the standby consumption of a complete machine. Define the measurement boundary and

Line Regulation vs Load Regulation: Compare Power Supplies on the Same Basis

Separate input-driven and load-driven steady-state changes, normalize the units, and use a nine-point matrix to expose an interaction that two

Power Supply Switching Frequency: Review the Interface to Sensitive Equipment

A nominal switching frequency does not predict equipment compatibility. Map its operating range to sampling clocks and protected signal bands,

Common Mode Current in Isolated DC-DC Converters: Review the Capacitive Path

An isolation barrier interrupts a conductive path but still has parasitic capacitance. Use edge-current calculations and a controlled connection matrix

Hipot Test Records for OEM Power Supplies: What Buyers Should Verify

A hipot pass becomes useful procurement evidence when it identifies the exact assembly, insulation path, approved test program, and result.

EFT Test Planning for Power Supplies: Ports, Recovery, and System Evidence

A power supply surviving an EFT test does not show that the complete machine kept working. Define the tested ports,

ESD Testing for Powered Equipment: Ports, Resets, and Functional Evidence

A component ESD rating does not qualify the complete powered product. Map accessible points and record power, firmware, and interface

Voltage Sag and Power Supply Brownout: Define Equipment Recovery

Translate an AC sag into a reproducible event and define what the equipment must do during the disturbance and after

Non-Isolated DC-DC Converter Grounding: Plan the Shared Return

A common-negative converter shares an electrical reference. Trace load, signal and service connections before deciding where return current is allowed