Fuente de alimentación de salida única LRS-600W

The LRS-600 is a 600W-class single-output enclosed power supply with 5V, 12V, 15V, 24V, 36V and 48V versions. Select the exact version and listed current range for the load. Select 90–132VAC or 180–264VAC using the input-range switch; the DC input range is 255–370VDC (Switch on 230VAC) and the AC frequency range is 47–63Hz. The enclosure is fan-equipped. Its working range is -30°C to +70°C at 20%–90% RH, non-condensing. Confirm the actual enclosure version and mounting dimensions before final equipment layout, and confirm permissible loading for the installation.

Si está interesado en esta serie, contáctenos en Correo electrónico: [email protected]

LRS-600 representative shown

LRS-600 Enclosed Switching Power Supply

Single-output AC–DC supply with switch-selectable AC input.

Voltaje de salida
Modelo
LRS-600-12LRS-600-15LRS-600-24LRS-600-36LRS-600-48
DC output
12 V · 0–50 A15 V · 0–40 A24 V · 0–25 A36 V · 0–16.6 A48 V · 0–12.5 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
255–370 V DC (switch on 230 V AC)
Eficiencia
90%90%91%92%92%
Dimensions (L × W × H)
Version-dependent; see drawing

Specifications & models

ParámetroLRS-600-12LRS-600-15LRS-600-24LRS-600-36LRS-600-48
DC output voltage and current12V 0~50A15V 0~40A24V 0~25A36V 0~16.6A48V 0~12.5A
Rango de voltaje de entrada90–132VAC / 180–264VAC by switch; 255–370VDC (Switch on 230VAC); 47–63Hz
DimensionesDimensional references (L × W × H): Dimension entry 225 × 115 × 50 mm; table-heading reference 225 × 144 × 41 mm; mechanical drawing body 225 × 124 × 41 mm, with a 144 mm span including mounting ears. Confirm the actual version and mounting dimensions before specifying the installation space.
Eficiencia90%90%91%92%92%
Working temperature / humidity-30°C to +70°C / 20%–90% RH, non-condensing. Storage: -40°C to +85°C / 10%–95% RH, non-condensing. Confirm permissible loading for the actual installation temperature.
Ondulación y ruido200mVp-p240mVp-p240mVp-p360mVp-P en360mVp-P en
Regulación de línea±0,5%
Regulación de carga±1%±0,5%±0,5%±0,5%±0,5%
DC voltage adjustment11.4–13.2V14.25–16.5V22.8–26.4V34.2–39.6V45.6–52.8V
Input / cold-start / leakage currentInput current: 12A/115VAC, 7.5A/230VAC. Cold-start current: 35A/115VAC, 60A/230VAC. Leakage current: <0.7mA @ 240V.
Protección contra sobrecarga105%–150% of rated output power. Hiccup mode; automatic recovery after the abnormal condition is removed.
Protección contra sobretensión13.8–16.2V18–21V28.8–33.6V41.4–48.6V55.2–64.8V
Overvoltage recoveryHiccup mode; automatic recovery after the abnormal condition is removed.
Short-circuit protectionOutput terminal short circuit: hiccup mode; automatic recovery after the abnormal condition is removed.
Protección contra sobrecalentamientoAutomatic recovery once the temperature returns to normal.
Timing (setup / rise / hold-up)1300ms, 50ms/230VAC; 1300ms, 50ms/115VAC at full load. No separate hold-up time is specified.
Voltaje de soporteI/P-O/P: 4kVAC; I/P-FG: 2kVAC; O/P-FG: 1.25kVAC
Resistencia a aislamientoI/P-O/P, I/P-FG, O/P-FG: 100M Ohm / 500VDC
Peso0.95kg
Embalaje45,5 × 31,5 × 26 CM/20 piezas/20 kg
Output options
ProducciónActualEficienciaOnda (mVp-p)
12 V0–50 A90%200
15 V0–40 A90%240
24 V0–25 A91%240
36 V0–16.6 A92%360
48 V0–12.5 A92%360
Regulación de carga
12 V±1%
15 V±0,5%
24 V±0,5%
36 V±0,5%
48 V±0,5%
DC voltage adjustment
12 V11.4–13.2V
15 V14.25–16.5V
24 V22.8–26.4V
36 V34.2–39.6V
48 V45.6–52.8V
Protección contra sobretensión
12 V13.8–16.2V
15 V18–21V
24 V28.8–33.6V
36 V41.4–48.6V
48 V55.2–64.8V
Common specifications
Rango de voltaje de entrada90–132VAC / 180–264VAC by switch; 255–370VDC (Switch on 230VAC); 47–63Hz
DimensionesDimensional references (L × W × H): Dimension entry 225 × 115 × 50 mm; table-heading reference 225 × 144 × 41 mm; mechanical drawing body 225 × 124 × 41 mm, with a 144 mm span including mounting ears. Confirm the actual version and mounting dimensions before specifying the installation space.
Working temperature / humidity-30°C to +70°C / 20%–90% RH, non-condensing. Storage: -40°C to +85°C / 10%–95% RH, non-condensing. Confirm permissible loading for the actual installation temperature.
Regulación de línea±0,5%
Input / cold-start / leakage currentInput current: 12A/115VAC, 7.5A/230VAC. Cold-start current: 35A/115VAC, 60A/230VAC. Leakage current: <0.7mA @ 240V.
Protección contra sobrecarga105%–150% of rated output power. Hiccup mode; automatic recovery after the abnormal condition is removed.
Overvoltage recoveryHiccup mode; automatic recovery after the abnormal condition is removed.
Short-circuit protectionOutput terminal short circuit: hiccup mode; automatic recovery after the abnormal condition is removed.
Protección contra sobrecalentamientoAutomatic recovery once the temperature returns to normal.
Timing (setup / rise / hold-up)1300ms, 50ms/230VAC; 1300ms, 50ms/115VAC at full load. No separate hold-up time is specified.
Voltaje de soporteI/P-O/P: 4kVAC; I/P-FG: 2kVAC; O/P-FG: 1.25kVAC
Resistencia a aislamientoI/P-O/P, I/P-FG, O/P-FG: 100M Ohm / 500VDC
Peso0.95kg
Embalaje45,5 × 31,5 × 26 CM/20 piezas/20 kg

Dimensions & derating

Mechanical dimensions

Version-dependent; see drawing (L × W × H)

Wide face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
Narrow face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
LRS-600 — dimensions in millimetres
Dimension entry225 × 115 × 50 mm
Table-heading reference225 × 144 × 41 mm
Mechanical drawing body225 × 124 × 41 mm
Span including mounting ears144 mm

Dimensions in millimetres. The dimension entry, table heading and mechanical drawing give different references. Confirm the enclosure version and mounting dimensions before installation.

Load derating

Use these curves only within their -20 to +65 °C coverage and the WEHO input limits. They do not define load limits for the unplotted -30 to -20 °C or +65 to +70 °C parts of the table's operating range. Do not extrapolate.

Normalized load curve. Use the WEHO output table for absolute ratings; follow the plotted voltage, mounting and temperature conditions.
Use the “Others” trace for the listed outputs. The separate 5 V curve does not apply to the versions offered here.
Normalized load curve. Use the WEHO output table for absolute ratings; follow the plotted voltage, mounting and temperature conditions.
Permitted load versus AC input voltage at the shown frequency. Follow the input-selector setting. Use the WEHO output table for absolute current ratings.
View the functional block diagram Functional block diagram. The WEHO specification table governs output ratings, protection thresholds and recovery.

Functional stages are shown here; the specification table governs rated output, protection thresholds and recovery.

Product overview

For a 24 V control rail, the LRS-600-24 has a listed output range of 0–25 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. Check the voltage-adjustment limits for the selected output. Check both the electrical column and the actual housing revision before completing the panel design.

Panel fit: The dimension row says 225 × 115 × 50 mm, the heading says 225 × 144 × 41 mm and the drawing shows a 225 × 124 × 41 mm body with a 144 mm ear span. Confirm the housing before committing the panel layout.

Design features

CaracterísticaWhat to check
Output trimOn LRS-600-24, the output adjusts from 22.8 to 26.4 V. Check the limits for the specific output.
Enclosure fitConfirm the mounting dimensions and allow room for wiring bends, airflow and terminal access.
Overload recoveryThe output recovers after the overload condition is removed. Check how the equipment restarts.

Installation & applications

Installation checks

A closed instrument, a clipboard and a handheld meter on a workshop bench.

Match the supply to the load

Check the incoming supply against 90–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.

A closed, vented equipment cabinet beside a clear service aisle and a wall grille.

Leave room for service

The sheet gives different body and mounting references. Verify the physical version and ear span before drilling the panel.

An environmental test chamber with a lit observation window and an instrument cart.

Check the installed temperature

The listed working range is -30 to +70 °C. Measure the air near the installed supply under sustained load. Use the applicable loading curve within its stated limits.

An empty roller conveyor behind a yellow barrier, with a closed equipment cabinet beside it.

Plan for power returning

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

A freestanding illuminated lightbox outside a glass-fronted shop at dusk.

Retail signage

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.

24 V option: LRS-600-24 · listed current 0–25 A.

Indoor parcel lockers with a touchscreen and a parcel in an open compartment.

Parcel lockers

Size the rail for sensors and the operator interface. Account separately for lock pickup current.

12 V option: LRS-600-12 · listed current 0–50 A.

A carton passes a bracket-mounted photoelectric sensor with an amber status light on a conveyor belt.

Carton packaging

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.

24 V option: LRS-600-24 · listed current 0–25 A.

A circuit board clamped below an inspection camera, with an enlarged board view on a monitor.

Electronics test fixtures

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.

12 V option: LRS-600-12 · listed current 0–50 A.

AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.

Frequently asked questions

Which output voltages are available?

Choose one nominal output: 12 V, 15 V, 24 V, 36 V, 48 V. Each voltage is a separate model.

Which input voltage should I specify?

The listed AC input is 90–132 V AC / 180–264 V AC (by switch); the DC input is 255–370 V DC (switch on 230 V AC). The gap between the two AC bands is not part of the specified input range.

How much current is listed for the 24 V model?

LRS-600-24 is listed at 0–25 A. Check the current at startup as well as in steady operation.

What does the series power designation mean?

The datasheet gives output current by voltage. Use the selected model’s current range and application conditions rather than treating the series name as a continuous rating for every version.

What temperature range can I use?

The working range is -30 to +70 °C. The curves cover only −20 to +65 °C. Do not extrapolate into the remaining temperature range.

How do I check the mounting space?

Check each dimension reference and confirm the enclosure version before installation.

What inrush current is listed?

The cold-start input current is 35 A at 115 V AC, 60 A at 230 V AC. This is an input-side event, not the current available to the DC load.

What should I include in my quote request?

Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.

In the inquiry form, enter model LRS-600-12LRS-600-15LRS-600-24LRS-600-36LRS-600-48 with your requirements.

LRS-600 datasheet

Close
Download PDF
LRS-600 datasheet, page 1 of 2: Electrical specifications.
LRS-600 datasheet, page 2 of 2: Mechanical drawing and performance curves.

LRS-600 product photograph

LRS-600 representative product photograph

Wide face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Narrow face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Use the “Others” trace for the listed outputs. The separate 5 V curve does not apply to the versions offered here.

Normalized load curve. Use the WEHO output table for absolute ratings; follow the plotted voltage, mounting and temperature conditions.

Permitted load versus AC input voltage at the shown frequency. Follow the input-selector setting. Use the WEHO output table for absolute current ratings.

Normalized load curve. Use the WEHO output table for absolute ratings; follow the plotted voltage, mounting and temperature conditions.

¿Cuáles son los mejores productos de fuentes de alimentación para su empresa?

Impulsa tu negocio con productos de suministro de energía de calidad WEHO.

Pregúntale a un experto
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.