SP-3000 High Power Switching Power Supply
SP-3000 is a 3KW single output chassis type AC to DC power supply. The entire series input voltage range is 95-265VAC, and can provide DC output for most industrial needs.
Each chassis can be air-cooled through an internal speed-controlled fan, and the operating temperature is close to 60°C.Built-in multiple functions such as output voltage,Current adjustable, current sharing, remote on/off control, 485 communication control, auxiliary power supply and other functions provide a variety of flexible designs.If you have any questions, please do not hesitate to contact us atEmail: [email protected]
- Penerangan
Ciri -ciri
1 、 Julat Input Voltan: 95-265VAC
2 、 Jenis Perlindungan: litar pintas/overcurrent/overvoltage/overtemperature
3 、 Faktor Kuasa PF ≧ 0.99
4 、 Kecekapan kerja sehingga 93%
5、485 Kawalan Komunikasi
Parameter teknikal
| Model | SP-3000-12 | SP-3000-24 | SP-3000-36 | SP-3000-48 | SP-3000-60 | SP-3000-220 | |
| Output | Voltan DC | 12v | 24V | 36V | 48v | 60v | 220v |
| Arus dinilai | 180A | 125A | 83.3A | 62.5A | 50A | 13.6A | |
| Julat Semasa | 0 – 180A | 0 – 125A | 0 – 83.3A | 0 – 62.5A | 0 – 50A | 0 – 13.6A | |
| Kuasa dinilai | 2700W | 3000W | |||||
| Riak | 200mV | 200mV | 260mV | 300mV | 500mv | 1000mv | |
| Julat optimum semasa yang berterusan | 6 – 15V | 12 - 24V | 18 - 36V | 24 - 48V | 30 - 60V | 110 - 220V | |
| Ketepatan voltan yang dinilai | ± 1.0% | ||||||
| Peraturan garis | ± 1.0% | ||||||
| Peraturan beban | ± 1.0% | ||||||
| Masa permulaan & bangkit | 1500ms, 700ms/230vac (dimuatkan sepenuhnya) | ||||||
| Input | Julat voltan | 95-190VAC (output semasa 50%), 195-265VAC (output semasa 100%) | |||||
| Julat kekerapan | 45Hz - 65Hz | ||||||
| Faktor kuasa | PF ≧ 0.99/230VAC (dimuatkan sepenuhnya) | ||||||
| Efficinecy(MAX) | 87 % | 90 % | 91.5 % | 92 % | 92.5 % | 93 % | |
| Ac Current | <18A | ||||||
| Arus kebocoran | < 3.0mA / 240VAC | ||||||
| Melindungi | Litar pintas | Apabila arus malar dimasukkan dan voltan lebih rendah daripada 10% voltan yang diberi nilai, output ditutup dan dikunci selepas 1 saat, dan pulih selepas dimulakan semula. | |||||
| Overcurrent | Pengguna boleh menetapkan nilai yang berlebihan untuk melambatkan output selama 5 saat dan kemudian menutup output, dan kemudian disambung semula selepas dimulakan semula. | ||||||
| Tekanan berlebihan | Pengguna boleh menetapkan nilai overvoltage untuk menutup voltan output, dan pulihkan selepas dimulakan semula | ||||||
| Lebih dari suhu | Matikan output, pulih atau mulakan semula secara automatik selepas suhu jatuh | ||||||
| Fungsi | Pelarasan voltan output | 0 – 15V | 0 - 26.4v | 0 - 39.6V | 0 - 52.8v | 0 - 66V | 0 - 242V |
| Output pelarasan arus berterusan | 0 – 180A | 0 – 125A | 0 – 83.3A | 0 – 62.5A | 0 – 50A | 0 – 13.6A | |
| Current Sharing | Parallel current sharing | ||||||
| Bekalan kuasa tambahan terpencil | 12V 0.5A | ||||||
| Output Remote Switch | Default power on, high level power off (5V-12V) | ||||||
| Output isyarat penggera | Power Good Signal (Dry Contact≦36V,0.1A) | ||||||
| Persekitaran | Suhu operasi | -20 - +60 ℃ | |||||
| Kelembapan operasi | -20 -90% RH Tiada Pemeluwapan | ||||||
| Suhu penyimpanan dan kelembapan | -40 - +85 ℃, 10 -95% RH Tiada pemeluwapan | ||||||
| Rintangan getaran | 10 – 500Hz, 2G 10 Min/cycle, X、Y、Z 60 Min | ||||||
| Keselamatan | Rintangan penebat | Input ke Output: 100mhms/500VDC/25 ℃/70%rh | |||||
| Rintangan tekanan | I/P-O/P: 2KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC | ||||||
| Yang lain | Saiz | 289*174*69mm(L*W*H) | |||||
| Berat bersih | 3.3 KG | ||||||
| Catatan | 1. Semua parameter diukur pada voltan input 230VAC, beban undian dan 25 ℃ melainkan dinyatakan sebaliknya. 2. Ripple dan voltan bunyi diukur dengan oscilloscope jalur lebar 20MHz dengan 0.1μ dan 47μ kapasitor ditambah pada akhir pasangan berpintal 12 inci, dan diukur pada jalur lebar 20MHz. 3. Ketepatan: Termasuk ralat menetapkan, kadar peraturan linear dan kadar peraturan beban. 4. Output must be derated for low input voltage. Please refer to the static characteristic curve for details. 5. Startup time is measured under cold start. Frequent switching may increase the startup time. | ||||||
Lengkung ciri statik
Installation Dimensions
Apakah produk bekalan kuasa terbaik untuk perniagaan anda?
Meningkatkan perniagaan anda dengan produk bekalan kuasa berkualiti WEHO.
Tanya pakar