The PSC-250W provides 250W of backup-ready power with 12V/14.5A or 24V/10A outputs. It features adjustable voltage (11.3–14.9V for 12V models) and 89% efficiency. Designed for high-demand environments, it offers overload protection, low-battery cutoff, and seamless AC/battery. The 215×115×30mm chassis (0.75kg) includes LED indicators and operates in -20°C to +60°C. Suitable for servers, industrial controllers, and LED signage, its universal input (90–264VAC) and 1.5kV isolation ensure reliability in commercial and harsh settings.

  Model PSC-350-12 PSC-350-24
  DC Output Voltage CH1:13.8V CH2:13.8V CH1:27.6V CH2:27.6V
  Output Voltage Tolerance ±1% —– ±1% —–
  Rated Output Current 20A 5A(charge) 10A 25A(charge)
  Output Current Range 0~25A —- 0~12.5A —–
  Output Power 345W 350W
  Ripple and Noise 180mVp-P —– 200mVp-P —–
  Adjustable Range of DC Voltage CH1:11.3~14.9V CH1:21.3~29.8V
  Start-up,Rise,and Hold Time 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC.
  Input Voltage Range 90~264VACor 135~370VDC
  ACInput Current 6.5A/115VAC 3.5A/230VAC
  Efficiency 89% 89%
  Inrush Current Cold Start Current 45A/115VAC           55A/230VAC
  Leakage Current <lmA/240VAC
  Overload Protection Overload protection will be activated at 105%to 115%of the rated output power
Protetion mode:ACcharging mode:Isolation mode,the system can automaticall resume operation afer the abnormal load condition is removed.
  Low Battery Voltage Protection 9.5~10.3V 19~20.5V
Protection mode:Output cut-off.
  Introduction to UPS Function Long-term online float charging for batteries with high efficiency,over 98%fullness.
Automatically stops charging when full to prevent overcharge and extend battery life
Automaticswitch between utility power and batery without delay,no manual operation needed.
Cold start capability allows UPSto start directly from battery in case of no utility power,meeting emergency needs.
  Operating Temperature and Humidity -20°Cto~60°C;20%~90%RH(Please refer to theload derating curve).
  Storage Temperature and Humidity -20℃~+85℃;10%~95%RHNon-condensing
  Shock Resistance 10~500Hz,2G 10min./per cycle,duration 60 minutes,on each axis
  Voltage Withstanding Capability Between input andoutput:1.5kVAC Between input and ground:1.5kVAC Between output and ground:0.5kVDC
  Insulation Resistanc Between input and output,input and ground,output and ground:100MQ/500 VDC
  Dimensions 215*115*30mm(L*W*H)
  Packaging 0.85kg/20pcs/18.5kg/0.041m³