Something You Should Know about Cooling FAN

Dedicated to power supply after-sales service for more than a decade, I feel honored to witness the power supply industry’s evolution in both the circuit design technology and the compact parts size. Under this trend, the power density of the power supply has been continuously improved, and so is the product volume.

To achieve the high power density for high-wattage power supplies, the heat dissipation issue is non-negligible. The easiest solution is to implement a fan to enhance heat dissipation. To enhance the efficiency of the fan, the wind direction of the fan is changed from suck-out to blow-in, a change that both the temperature of the components and the internal space volume of the product can be greatly reduced. However, because of the unsynchronized customer’s habits, such design change relatively brings other issues.

Common problems for FAN with blow-in direction:

Figure 1

Dust floating in the air is sucked by the fan and attached to the iron net. Accumulating over time, the amount of dust jams the iron net, a fact that causes insufficient air intake and lead to a serious downgrade effect on heat dissipation. Moreover, the jam situation can trigger the “FAN LOCK” function, shutting down the machine.

Figure 2

Dust accumulated between components at the windward side caused insufficient heat dissipation. If moisture is absorbed at the same time, it is possible to cause a decrease of withstand voltage, arcing or short-circuit between components can be expected.

Figure 3

The original design of the distance between the two high-voltage copper foils fulfills safety requirement, but it no long the same if dust accumulated over the time. When those dusts absorb moisture, which will cause the resistance dropped, and finally causing arcing.

Comparison between two different wind direction and Fanless : 

Advantage Disadvantage Application
Blow-in · High performance in heat dissipation

· Not require extra heat dissipation designs

· Compact volume

· Affected by environmental issues, moisture

· High possibility of arcing at the windward

· Accumulated Dust on FAN

· Corrosion of metal parts

Engine room
Suck-out Mid-level performance in heat dissipation

Affected by environment less

Less dust accumulation issue

· Longer product lifecycle.

· Affected by environmental issues, moisture

· Higher internal temperature

· Larger volume

Open field Cabinet
Factory

 

Structure Advantage Application
Fanless
Convention cooling
• Wide application usage
• Low cost
• No extra power consumption
• Noise and vibration-free
• Low maintenance fee
• Easy installation
• Low power density application.
• Application requires noise and vibration-free such as medical device, indoor lighting, security system, and precision instrument

Latest News

How to Choose the Right Option for Your Lighting from LED Drivers and Transformers?

How to Choose the Right Option for Your Lighting from LED Drivers and Transformers?

Feb 29, 2024
What is a LED Driver and How do I Choose the Right One?

What is a LED Driver and How do I Choose the Right One?

Feb 20, 2024
Electrical Transformers: An In-Depth Guide to the Fundamentals

Electrical Transformers: An In-Depth Guide to the Fundamentals

Feb 10, 2024
What Are the Benefits of Using Direct Electricity in Buildings?

What Are the Benefits of Using Direct Electricity in Buildings?

Jan 26, 2024
A Guide to Choosing the Right AC/DC Adapter

A Guide to Choosing the Right AC/DC Adapter

Jan 23, 2024
A Comprehensive Guide to DC and AC in Electronics

A Comprehensive Guide to DC and AC in Electronics

Jan 14, 2024

Contact us