- An LED driver's normal output rating does not establish its open-load voltage or hot-plug permission.
- Obtain the exact model's no-load, protection, discharge and restart information before approving a service sequence.
- Stored capacitor energy increases with the square of voltage; energy alone cannot predict the reconnection current peak.
- Reconnect using the manufacturer's documented, de-energized procedure unless the exact assembly explicitly supports another method.

Define what happens when the LED circuit opens
An open LED circuit changes the driver's operating condition, so a successful normal-load test cannot approve the subsequent reconnection. The missing evidence concerns the output before contact, the energy available during contact and the driver's recovery afterward. A connector that fits does not answer those questions.
For a project considering the WEHO XLG-60 product family, identify the ordered XLG-60-24 unit and its applicable documents first. The pictured enclosure supplies product context. Its appearance does not establish an open-circuit voltage, a particular protection response or permission to reconnect an energized LED load.
Separate a broken LED string, an unplugged service connector and a deliberate secondary-side switch in the design record. Each can leave the output unloaded, but the frequency, contact behavior and intended recovery differ. A service procedure should not silently become permission for repetitive output switching.
Keep normal regulation, no-load behavior and recovery separate
A constant-voltage load system and a directly driven constant-current LED string need different operating information. A regulated nominal voltage is not automatically the maximum output during every abnormal state. Likewise, a constant-current operating window does not describe every possible unloaded or protection state.
MEAN WELL's LED driver application notes distinguish normal drive arrangements and warn about connecting an LED load after the supply has already been energized. That warning supports checking connection order. It does not establish the protection design or open-load behavior of a WEHO product.
Ask for four separate answers: the permitted no-load state, the maximum applicable output voltage, the required reconnection procedure and the permitted restart sequence. Keep stated conditions attached to each answer. Temperature, input condition and product suffix can matter even when the main model family is unchanged.
The LED driver output-window guide addresses compatibility while the intended LED load is operating. Extend that qualification with a separate service-state record rather than treating a normal operating window as a hot-plug specification. The two decisions belong in the same project file but have different acceptance evidence.

Use stored energy to understand the question, not approve the connection
For a capacitor at voltage V, stored energy is E = ½CV². This relationship explains why an unloaded output voltage can change the energy associated with a subsequent connection. The calculation does not describe the full driver, the LED junction response or the connector's transient behavior.
Consider a hypothetical engineering comparison, not an XLG-60 measurement. Assume an output-side capacitance of 470 µF, represented as an ideal capacitor. Compare a 24 V state with a 36 V state solely to show the voltage sensitivity of stored energy.
At 24 V, E = 0.5 × 470 × 10⁻⁶ F × (24 V)² = 0.13536 J. At 36 V, E = 0.5 × 470 × 10⁻⁶ F × (36 V)² = 0.30456 J. Increasing the assumed voltage by 50% therefore increases the ideal stored energy by a factor of 2.25.
The difference is 0.30456 − 0.13536 = 0.16920 J. That difference is not a predicted energy pulse absorbed by an LED: the circuit can dissipate energy elsewhere, and the driver may continue supplying energy. It is a reason to request the real output-state and connection evidence.
Swipe horizontally on a small screen, or open the full-size diagram.
| Illustrative quantity | 24 V state | 36 V state | What the comparison establishes |
|---|---|---|---|
| Assumed capacitance | 470 µF | 470 µF | Identical ideal capacitor for this example |
| Calculated stored energy | 0.13536 J | 0.30456 J | Energy depends on voltage squared |
| Energy ratio | Reference: 1.00 | 2.25 | A voltage change has a larger energy effect |
| Reconnection current peak | Not determined | Not determined | Requires the actual circuit and transient evidence |
A current-peak prediction additionally needs the relevant impedances, contact transition, wiring, LED behavior and source response. Dividing stored energy by an arbitrary time would produce an unsupported average power, not a validated surge limit. Do not turn the ideal capacitor comparison into a maximum safe cable length, waiting time or connector rating.
Obtain an explicit reconnection instruction
A protection entry such as “overvoltage protection” does not by itself authorize secondary-side connection while energized. The protection threshold, sensing location and reset behavior may address a different failure condition. Ask whether the manufacturer's instructions explicitly cover the proposed service action.
A Tridonic driver datasheet treats secondary switching and hot plug-in as explicit application restrictions. The restriction belongs to that named product, rather than to every driver on the market. Its useful lesson for procurement is to request a clear, model-specific statement instead of inferring permission from a generic protection list.
Connection disturbances also extend beyond a simple steady-state load change. Analog Devices discusses hot-swap-related transients in its power-supply fault-protection explanation. This is general circuit context; it does not supply a WEHO surge rating or approve a particular external protection component.
Retain the manufacturer's actual sequence, including any required input isolation, verification and restart conditions. Do not replace it with a waiting interval borrowed from another model. If a service connector can be operated unintentionally during normal use, address that access condition in the equipment design as well as in the written procedure.
Build a service-state acceptance record
- Identify the assembly. Record the full driver label, revision, LED module, connector and any intervening control electronics. Accept the document set only when the supplier confirms which instructions apply to that combination.
- Define the open condition. State whether the circuit opens through a fault, service disconnection or intended switching function. Record which energy sources remain present; accept the scenario only when every source and connection state is identified.
- Resolve the permitted sequence. Retain the manufacturer's reconnection and restart instructions. If the proposed action is not covered, keep it unresolved and request a supported alternative before approving the service method.
- Specify a controlled validation. Have the responsible engineer define an appropriate fixture, instrumentation and operating matrix. Record output state and restoration behavior against documented limits; do not create a live hot-plug experiment when the action is prohibited or undocumented.
- Release the service instruction. Tie the accepted sequence to the exact assembly and retain the review result. Reopen the assessment when the LED module, driver variant, connector or switching arrangement changes.
The record should distinguish missing documentation from a failed validation. “No instruction supplied” does not demonstrate that the product is defective, but it also does not support approving an undocumented action. That distinction keeps procurement questions precise and prevents field personnel from receiving an assumed procedure.
Send WEHO the proposed connection state
For an XLG-60-24 application review, send the complete label, LED module requirements and a simple description of when the output circuit opens. Identify the service connector and whether input power is intended to remain present. Request the applicable no-load, maximum-output, reconnection and restart documentation before freezing the equipment instruction.
Frequently asked questions
Does a 24 V label guarantee a 24 V open-load limit?
No. The label identifies normal rated information, while no-load limits and abnormal-state behavior require the applicable specification. Obtain the exact ordered model's information rather than estimating a limit from the family name or another manufacturer's product.
Does overvoltage protection make energized LED connection acceptable?
No. A protection label does not establish permission for the connection event. The manufacturer must cover the proposed action, and the complete assembly must remain within the relevant component and equipment requirements.
Can stored energy predict the LED current surge?
No. Capacitance and voltage determine an ideal stored-energy quantity, while peak current depends on the actual source, wiring, contacts and load response. Use the calculation to identify the evidence needed, then rely on an approved transient assessment.
Can one reconnection procedure cover every replacement driver?
Only when the applicable documentation and assembly qualification support that scope. Preserve the driver variant and LED identity in the service record, and reassess the sequence when either changes.