EDR-150 150W Industrial Din Rail Ac to Dc Single Output Switching Power Supply

EDR-150 is one economical slim Din Rail Power Supply Series,providing up to 156W at 230VAC Input.
The body is designed 40mm in width,which allows space saving inside the cabinetsEDR-150 is designed with metal housing that enhances the unit’s power dissipation.With working efficiency up to 87%,the entire series can operate at the ambient temperature between -20℃ and 60℃ under air convectionOther standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status. If you have any questions, please do not hesitate to contact us atEmail: [email protected]

EDR-150-24 · photographed sample

EDR-150 Single-Output DIN Rail Power Supply

Choose 24 V or 48 V for a 150 W-class DIN rail supply. Each suffix identifies a separate output version.

Select output voltage
Model
EDR-150-24EDR-150-48
DC output
24 V · 115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A48 V · 115 VAC: 0–3.1 A; 230 VAC: 0–3.1 A
AC input
90–264 VAC
DC input
127–370 VDC
Efficiency
85%86%
Dimensions
40 × 125.2 × 113.5 mm

Specifications & models

ParameterEDR-150-24EDR-150-48
DC output voltage and current24 V · 115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A48 V · 115 VAC: 0–3.1 A; 230 VAC: 0–3.1 A
Efficiency85%86%
Ripple and noise120 mV p-p150 mV p-p
Line regulation±0.5%±0.5%
Load regulation±1%±1%
DC voltage adjustment±10%±10%
AC input90–264 VAC
DC input127–370 VDC
Dimensions40 × 125.2 × 113.5 mm
Family power class150 W (single output)
Input frequency47–63 Hz
Cold-start inrush20 A at 115 VAC; 35 A at 230 VAC
Overload protection105–130%: output cutoff; automatic recovery.
Overvoltage protection115–140% of rated output power (sheet wording); output shuts down. Reapply power to recover. No voltage trip level is specified.
Setup / rise1500 / 100 ms at 230 VAC; 3000 / 100 ms at 115 VAC, full load. Hold-up time is not specified.
Withstand voltageInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV; 1 minute.
Insulation resistanceInput/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25 °C and 70% RH.
Working environment−20 to +60 °C
Unit weight0.56 kg
Packing42.5 × 29 × 27.5 cm / 36 pcs / 20 kg
Output options
ModelOutputCurrentEfficiency
EDR-150-2424 V115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A85%
EDR-150-4848 V115 VAC: 0–3.1 A; 230 VAC: 0–3.1 A86%
Additional model specifications
EDR-150-24
Ripple and noise120 mV p-p
Line regulation±0.5%
Load regulation±1%
DC voltage adjustment±10%
EDR-150-48
Ripple and noise150 mV p-p
Line regulation±0.5%
Load regulation±1%
DC voltage adjustment±10%
Common specifications
AC input90–264 VAC
DC input127–370 VDC
Dimensions40 × 125.2 × 113.5 mm
Family power class150 W (single output)
Input frequency47–63 Hz
Cold-start inrush20 A at 115 VAC; 35 A at 230 VAC
Overload protection105–130%: output cutoff; automatic recovery.
Overvoltage protection115–140% of rated output power (sheet wording); output shuts down. Reapply power to recover. No voltage trip level is specified.
Setup / rise1500 / 100 ms at 230 VAC; 3000 / 100 ms at 115 VAC, full load. Hold-up time is not specified.
Withstand voltageInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV; 1 minute.
Insulation resistanceInput/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25 °C and 70% RH.
Working environment−20 to +60 °C
Unit weight0.56 kg
Packing42.5 × 29 × 27.5 cm / 36 pcs / 20 kg

Dimensions & technical notes

Mechanical dimensions

40 × 125.2 × 113.5 mm

Side elevation
EDR-150 side elevation from the WEHO drawing.

Side elevation from the model sheet; dimensions in mm.

Front elevation
EDR-150 front elevation from the WEHO drawing.

Front elevation from the model sheet; dimensions in mm.

Top view
EDR-150 top view from the WEHO drawing.

Top view from the model sheet; dimensions in mm.

Bottom view
EDR-150 bottom view from the WEHO drawing.

Bottom view from the model sheet; dimensions in mm.

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +.

TB2: 4 and 5 = −V; 6 and 7 = +V.

The current range depends on the input voltage. The two input test conditions do not establish an unconditional maximum between them.

Product overview

Use EDR-150 where the panel needs one DC voltage. For example, EDR-150-24 provides 24 V at 115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A, while EDR-150-48 provides 48 V at 115 VAC: 0–3.1 A; 230 VAC: 0–3.1 A. Compare the actual load profile, not the suffix alone.

Design features

FeatureWhat to check
Output selection24 V or 48 V; choose one version for the required DC rail.
Input and restartAt cold start the input draws 20 A at 115 VAC; 35 A at 230 VAC. This transient is not available to the DC load.
Cabinet environment−20 to +60 °C. Check the intended load at the actual ambient temperature.

The current range depends on the input voltage. The two input test conditions do not establish an unconditional maximum between them.

Installation & applications

Installation checks

Reserve space on the rail for EDR-150.

Reserve space on the rail

The sheet lists 40 × 125.2 × 113.5 mm. Check terminal access and cable bends separately; the enclosure dimension is not an installation clearance.

Identify the terminal blocks for EDR-150.

Identify the terminal blocks

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +. TB2: 4 and 5 = −V; 6 and 7 = +V. Verify the markings on the unit before connecting power.

Check cabinet temperature for EDR-150.

Check cabinet temperature

−20 to +60 °C. Check the air temperature at the supply under the intended cabinet load. The temperature interval alone does not rate full output at its upper limit.

Allow for input inrush for EDR-150.

Allow for input inrush

The sheet gives 20 A at 115 VAC; 35 A at 230 VAC. Compare the applicable input condition with upstream protection; these are not DC load-current ratings.

Application examples

Orange welding robots work along the side-wall fixture for a rail vehicle.

Confirming a welding fixture is closed

A clamp-position switch can report fixture closure to the cell controller. This example concerns process feedback, not welding current, robot motion or a safety-rated interlock. For an external 24 V DC input, compare total running and peak demand with EDR-150-24 (115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A).

Photo: AKomkova — Линия сварки боковой стены вагона. «Тихвинский вагоностроительный завод».jpg · CC BY-SA 4.0 · Converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
An ultrasonic sensor projects over a water-treatment tank on a metal support.

Measuring tank level without contact

The level transmitter measures the distance to the liquid surface for the plant display. Check its DC input and signal interface rather than sizing for the pumps below. For an external 24 V DC input, compare total running and peak demand with EDR-150-24 (115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A).

Photo: Z22 — Ultrasonic level sensor used in a water treatment plant.jpg · CC BY-SA 4.0 · Converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
A signal tower stands above a guarded moulding machine with an overhead handling arm and discharge belt.

Showing moulding-cell status

A stack light can distinguish a running cycle from a call for an operator. Budget for all lamp segments that may light together; the mould heaters and handling arm are separate loads. For an external 24 V DC input, compare total running and peak demand with EDR-150-24 (115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A).

Photo: The robotic engineer1 — Injection Molding Machine with a robot arm.jpg · CC BY-SA 4.0 · Converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
A horizontal dyeing vessel stands beneath pipework and gauges in a textile workshop.

Recording dye-bath temperature

A probe transmitter can send dye-bath temperature to a recorder during a batch. Power the transmitter and recorder according to their inputs, not the vessel heater or circulation motor. For an external 24 V DC input, compare total running and peak demand with EDR-150-24 (115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A).

Photo: Sanjana Krishnamoorthy — Textile Dyeing Machine.jpg · CC BY 4.0 · Resized and converted to WebP; full frame. Illustrative only; no endorsement or verified installation.

Application images are illustrations of possible DC loads, not customer installations or verified equipment pairings.

Frequently asked questions

Which outputs are available?

The sheet lists 24 V or 48 V. Select the suffix that matches the load; these are separate output versions.

What current does the 24 V version supply?

EDR-150-24 is listed at 115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A. The two input conditions are distinct.

What input range should I specify?

The EDR-150 sheet lists 90–264 VAC at 47–63 Hz, or 127–370 VDC. State which supply will be present at the panel.

What happens after a fault?

105–130%: output cutoff; automatic recovery. Overvoltage: 115–140% of rated output power (sheet wording); output shuts down. Reapply power to recover. No voltage trip level is specified.

How should I check cabinet fit?

The sheet lists 40 × 125.2 × 113.5 mm. Allow space for the cable bend and access to the terminal blocks.

What information is useful for a quotation?

Give the full suffix (for example, EDR-150-24), input source, running and startup current, cabinet temperature, quantity and destination.

Send Inquiry

Tell us how many units you need and where they will be delivered.

EDR-150-24 sample, oblique view.
EDR-150-24 · photographed sample
Selected model
EDR-150-24EDR-150-48
DC output
24 V · 115 VAC: 0–5.2 A; 230 VAC: 0–6.5 A48 V · 115 VAC: 0–3.1 A; 230 VAC: 0–3.1 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.