PSC-150 12V 24V Ac to Dc Ups 3 Years Warranty Switching Power Supply
This 100W UPS-integrated power supply offers 12V/5A or 24V/2.5A outputs, with adjustable voltage ranges and 89% efficiency. It ensures uninterrupted power via automatic AC/battery and cold-start functionality. Built for reliability, it includes overload protection (105–115% load), hiccup-mode short-circuit recovery, and low-battery protection. The 129×97×30mm chassis (0.42kg) operates in -20°C to +60°C environments, suitable for POS systems, telecom equipment, and low-power industrial devices requiring stable backup power. Universal input (90–264VAC) and LED status indicators enhance versatility.
- Description
Model | PSC-150-12 | PSC-150-24 | ||
DC Output Voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
Output Voltage Tolerance | ±1% | —– | ±1% | —– |
Rated Output Current | 7.5A | 3A(charge) | 4A | 1.5A(charge) |
Output Current Range | 0~10.5A | —- | 0~0.55A | —– |
Output Power | 150W | 152W | ||
Ripple and Noise | 150mVp-P | —– | 200mVp-P | —– |
Adjustable Range of DCVoltage | CH1:11.3~14.9V | CH1:21.3~29.8V | ||
Start-up,Rise,and Hold Time | 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC. | |||
Input Voltage Range | 90~264VACor 135~370VDC | |||
ACInput Current | 3.2A/115VAC 1.6A/230VAC | |||
Efficiency | 87% | 89% | ||
Inrush Current | Cold Start Current 30A/115VAC 50A/230VAC | |||
Leakage Current | <1mA/240VAC | |||
Overload Protection | Overload protection will be activated at 105%to 115%of the rated output power. | |||
Protection mode:AC charging mode:Isolation mode,the system can automatically resume operation after the abnormal load condition is removed | ||||
Low Battery Voltage Protection | 9.5~10.3V | 19~20.5V | ||
Protection mode:Output cut-off | ||||
Introduction to UPS Function | Long-term online float charging for batteries with high efficiency,over 98%fullness. | |||
Automatically stops charging when full to prevent overcharge and extend battery life. | ||||
Automaicswich berwenutliypowerandbatey witouday,nomanudpeatonesded | ||||
Cold start capabliyallows UPSto start diectly from battery in caseofno utility power,meeting emergency needs. | ||||
Operating Temperature and Humidity | -20°Cto~60°C;20%~90%RH(Please refer to theload derating curve). | |||
Storage Temperature and Humidity | -20℃~+85℃;10%~95%RHNon-condensing | |||
Shock Resistance | 10~500Hz,2G 10min./per cycle,duration 60 minutes,on each axis | |||
Voltage Withstanding Capability | Between input andoutput:1.5kVAC Between inputand ground:1.5kVAC Between output and ground:0.5kVDC | |||
Insulation Resistanc | Between input and output,input and ground,output and ground:100MQ/500VDC | |||
Dimensions | 159*97*30mm(L*W*H) | |||
Packaging | 0.55kg/30pcs/18.5kg/0.041m³ |