| Model | LPV-100-5E | LPV-100-12E | LPV-100-15E | LPV-100-24E | LPV-100-36E | LPV-100-48E | |
| Output | DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A | |
| Current Range | 0 ~ 12A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 4.2A | 0 ~ 2.8A | 0 ~ 2.1A | |
| Rated Power | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W | |
| Ripple & Noise (max.) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
| Voltage Tolerance | ±8.0% | ±5.0% | |||||
| Line Regulation | ±1.0% | ||||||
| Load Regulation | ±6.0% | ±2.0% | |||||
| Setup, Rise Time | 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC | ||||||
| Hold Time (Typ.) | 50ms/230VAC 14ms/115VAC at full load | ||||||
| Input | Voltage Range | 90 ~ 264VAC 127 ~ 370VDC | |||||
| Frequency Range | 47 ~ 63Hz | ||||||
| Efficiency(Typ.) | 80% | 85% | 87% | 88% | 88% | 89% | |
| AC Current | 2.2A/115VAC 1.2A/230VAC | ||||||
| Inrush Current (max.) | COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC | ||||||
| Circuit Breaker | 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC | ||||||
| Leakage Current | 0.25mA / 240VAC | ||||||
| Protection | Over-load | 110% ~ 150% rated output power | |||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over Voltage | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
| Protection type: Shut down o/p voltage, re-power on to recover | |||||||
| Environment | Working Temp | -25°C ~ +70°C (Refer to “Derating Curve”) | |||||
| Working Humidity | 20% ~ 90%RH non-condensing | ||||||
| Storage Temp. Humidity | -40°C ~ +80°C; 10% ~ 95% RH | ||||||
| Temp Coefficient | ±0.03%/°C (0 ~ 50°C) | ||||||
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along the X, Y, and Z axes | ||||||
| Safety & EMC | Safety Standards | IP67 approved; design refer to EN60950-1 | |||||
| Withstand Voltage | I/P-O/P: 1.5KVAC | ||||||
| Isolation Resistance | I/P-O/P: >100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
| EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 | ||||||
| EMC Immunity | Compliance to EN55024, light industry level, criteria A | ||||||
| Others | MTBF | 703Khrs min. MIL-HDBK-217F (25°C) | |||||
| Dimension | 190*52*37mm (L*W*H) | ||||||
| Packing | 0.63Kg; 20pcs/13.6Kg/0.55CUFT | ||||||
Waterproof IP67 plastic LED driver AC 110v/220v to constant DC output 100W power supply
Discontinued series - historical reference only. Production of the LPV and LPVE series has stopped. This page and its technical documents are retained for historical reference.
Ask our team to review your application and help select an XLG or HLG model. Suitability must be confirmed for your specific requirements; no automatic or universal replacement is implied.
LPV-100E power supply series is a fantastic AC-to-DC converter for delivering constant voltage in wet and dusty environments.
It comes from LPV Series Plastic Waterproof Power Supply Series which operates off-line voltage (90-264VAC) and delivers constant voltages from 5-48VDC depending on your selection.The 20 to 60 Watt models qualify as Class 2 power units offered in a slim, butter stick design.If you have any questions, please do not hesitate to contact us at Email: [email protected]
- Description
It allows the end system to easily meet the worldwide energy requirement.
We are 100% responsible for quality.
This product has a universal AC input that is full range.
The product adopts a fully isolated plastic shell.
This product size is small and compact type.
Need help selecting an XLG or HLG model?
Ask our team to review your application and discuss XLG or HLG options. Model suitability requires individual confirmation.
Ask an Expert