Verify the input
Compare the nameplate with the incoming supply before wiring. For AC operation, the datasheet specifies 300–450 V AC at 47–63 Hz.
The WEHO LRH-150W series comprises robust 150W single output power supplies, designed for a versatile input voltage range of 300-450VAC or 420-635VDC.
If you have any questions, please do not hesitate to contact us at Email: [email protected]
380 V AC input class (300–450 V AC). Choose the DC output voltage that matches your load.
| Parameter | LRH-150-12 | LRH-150-15 | LRH-150-24 | LRH-150-48 |
|---|---|---|---|---|
| DC output voltage and current | 12 V · 0–12.5 A | 15 V · 0–10 A | 24 V · 0–6.5 A | 48 V · 0–3.3 A |
| Input voltage range | 300–450 V AC, 47–63 Hz / 420–635 V DC | |||
| Dimensions | 159 × 97 × 30 mm | |||
| Efficiency | 86.5% | 87% | 88% | 89% |
| Working temperature | −20 to +70 °C; full-load operation across this range is not specified. | |||
| Ripple & noise | 150 mVp-p | 150 mVp-p | 150 mVp-p | 200 mVp-p |
| Line regulation | ±0.5% | |||
| Load regulation | ±0.5% | |||
| Output voltage adjustment | ±10% | |||
| Inrush current | 60 A at 400 V AC (cold start) | |||
| Overload protection | 110–150%: output cuts off and recovers automatically. | |||
| Other protection | Overcurrent and short-circuit protection. | |||
| Timing (setup / rise / hold-up) | Setup 500 ms; rise 30 ms at 400 V AC. Hold-up time not specified. | |||
| Withstand voltage | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. | |||
| Insulation resistance | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). | |||
| Weight | 0.45 kg | |||
| Packing | 42.5 × 34 × 19.5 cm / 40 pcs / 17 kg | |||
| Output | Current | Efficiency | Ripple (mVp-p) |
|---|---|---|---|
| 12 V | 0–12.5 A | 86.5% | 150 |
| 15 V | 0–10 A | 87% | 150 |
| 24 V | 0–6.5 A | 88% | 150 |
| 48 V | 0–3.3 A | 89% | 200 |
| Input voltage range | 300–450 V AC, 47–63 Hz / 420–635 V DC |
|---|---|
| Dimensions | 159 × 97 × 30 mm |
| Working temperature | −20 to +70 °C; full-load operation across this range is not specified. |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Output voltage adjustment | ±10% |
| Inrush current | 60 A at 400 V AC (cold start) |
| Overload protection | 110–150%: output cuts off and recovers automatically. |
| Other protection | Overcurrent and short-circuit protection. |
| Timing (setup / rise / hold-up) | Setup 500 ms; rise 30 ms at 400 V AC. Hold-up time not specified. |
| Withstand voltage | Input–output 1.5 kV; input–frame 1.5 kV; output–frame 0.5 kV, 1 minute. |
| Insulation resistance | 100 MΩ at 500 V DC, 25 °C and 70% RH (input–output, input–frame and output–frame). |
| Weight | 0.45 kg |
| Packing | 42.5 × 34 × 19.5 cm / 40 pcs / 17 kg |
159 × 97 × 30 mm (length × width × height)
Dimensions in millimetres. Open the original views for mounting details.
The operating range is −20 to +70 °C. A load-versus-temperature curve for this model is not supplied here. Confirm the permissible load at your actual cabinet temperature.
For a packaging controller, compare the LRH-150-24 version (24 V · 0–6.5 A) with the total DC demand, including start-up. The 159 × 97 × 30 mm figure is the enclosure size, not the full service clearance.
| Feature | What to check |
|---|---|
| Output trim | Use the ±10% adjustment to fine-tune the rail within the load’s voltage limits. |
| Low-profile case | Allow space beyond the housing for airflow, wiring bends and access to the terminals. |
| Overload recovery | The output cuts off during overload and recovers automatically. Check how the equipment restarts. |

Compare the nameplate with the incoming supply before wiring. For AC operation, the datasheet specifies 300–450 V AC at 47–63 Hz.

Allow for the 159 × 97 × 30 mm enclosure, terminal access and cable bends.

Check the air temperature beside the supply during the longest duty cycle; a reading on the metal case is not the cabinet air temperature.

Confirm how the connected equipment responds when DC power returns, following the machine’s approved restart procedure.
Illustrations of the checks, not photographs of a tested installation.
Size the supply for the auxiliary electronics, not for the whole machine.
The HMI screen and tactile pushbuttons are examples of low-voltage loads to check when sizing a 380 V AC auxiliary supply for an operator station. The spindle drive is a separate load.
Size the 380 V AC-input auxiliary supply for safety light curtains, optical sensors and I/O modules—not for the robotic arm servo drives.
Account separately for the machine-vision camera, coaxial ring light and linear-stage controller loads when sizing the 380 V AC auxiliary supply.
AI-generated application illustrations for selection planning; not photographs of verified installations.
Each voltage is a separate version. 12 V, 15 V, 24 V, 48 V are listed.
300–450 V AC, 47–63 Hz / 420–635 V DC
No full-load limit at that temperature is established here. Ask for the permitted load in your mounting conditions.
Include LRH-150, desired output, continuous and start-up current, quantity and destination.
Use the theme inquiry form on this product page. Selected model: LRH-150-12LRH-150-15LRH-150-24LRH-150-48.








Boost your business with WEHO quality power supply prooducts.
Ask an Expert