PSC-60 12V 24V Ac to Dc Ups 3 Years Warranty Switching Power Supply
The WEHO PSC-60 series is an AC-DC power supply with a battery-charging function for UPS applications. Match the selected output version to the load and the battery system before use.
Email Us [email protected]
- Description
| Model | PSC-60-12 | PSC-60-24 | ||
| DC Output Voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
| Output Voltage Tolerance | ±1% | —– | ±1% | —– |
| Rated Output Current | 3.5A | 1A(charge) | 1.5A | 0.7A(charge) |
| Output Current Range | 0~4.5A | —– | 0~2.2A | —– |
| Output Power | 60W | 60W | ||
| Ripple and Noise | 150mVp-P | —– | 200mVp-P | —– |
| Adjustable Range of DCVoltage | CH1:11.3~14.9V | CH1:21.3~29.8V | ||
| Start-up,Rise,and Hold Time | 600ms,50ms,80ms/230VAC.1200ms.50ms.16ms/115VAC. | |||
| Input Voltage Range | 90~264VACor 135~370VDC | |||
| AC Input Current | 1.8A/115VAC 0.9A/230VAC | |||
| Efficiency | 86% | 88% | ||
| Inrush Current | Cold Start Current 25A/115VAC 40A/230VAC | |||
| Leakage Current | <lmA/240VAC | |||
| Overload Protection | Overload protection will be activated at 105%to 115%of the rated output power. | |||
| protection mode:ACcharging mode:Isolation mode,the system can automatically resume operation after the abnormal load condition is removed. | ||||
| Low Battery Voltage Protection | 9.5~10.3V | 19~20.5V | ||
| Protection mode:Output cut-off | ||||
| Introduction to UPS Function | Long-term online float charging for batteries with high efficiency,over 97%fullness. | |||
| Automatically stops charging when full to prevent overcharge and extend battery life | ||||
| automatic switch between thliy power and battery without delay,no manual operation needed | ||||
| Cold start capability allows UPSto start directly from battery in case of no utility power,meeting emergency needs. | ||||
| Operating Temperature and Humidity | -20°Cto~60°C;20%~90%RH(Please refer to theload derating curve). | |||
| Storage Temperature and Humidity | -20℃~+85℃;10%~95%RHNon-condensing | |||
| Shock Resistance | 10~500Hz,2G 10min./per cycle,duration 60 minutes,on each axis | |||
| Voltage Withstanding Capability | Between input andoutput:1.5kVAC Between input and ground:1.5kVAC Between output and ground:0.5kVDC | |||
| Insulation Resistanc | Between input and output,input and ground,output and ground:100MQ/500VDC | |||
| Dimensions | 129*97*30mm(L*W*H) | |||
| Packaging | 0.38kg/50pcs/21kg/0.041m³ | |||