NDR-120 Series 120W Slim Industrial DIN Rail Power Supply (NDR-120-12 / NDR-120-24 / NDR-120-48)

NDR-120 is a single-output DIN-rail switching power supply with separate 12V, 15V, 24V and 48V models. The specified input range is 85–264VAC or 120–370VDC, with 47–63Hz AC input. Working temperature is -10°C to +50°C. Check the selected output rating and installation conditions before ordering.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

NDR-120-24 · photographed sample

NDR-120 Single-Output DIN Rail Power Supply

Choose 12 V, 15 V, 24 V or 48 V for a 120 W-class DIN rail supply. Each suffix identifies a separate output version.

Select output voltage
Model
NDR-120-12NDR-120-15NDR-120-24NDR-120-48
DC output
12 V · 0–10 A15 V · 0–8 A24 V · 0–5 A48 V · 0–2.5 A
AC input
85–264 VAC
DC input
120–370 VDC
Efficiency
86%88%88%89%
Dimensions
40 × 125.2 × 113.5 mm

Specifications & models

ParameterNDR-120-12NDR-120-15NDR-120-24NDR-120-48
DC output voltage and current12 V · 0–10 A15 V · 0–8 A24 V · 0–5 A48 V · 0–2.5 A
Efficiency86%88%88%89%
Ripple and noise100 mV p-p120 mV p-p120 mV p-p150 mV p-p
Line regulation±0.5%±0.5%±0.5%±0.5%
Load regulation±0.5%±0.5%±0.5%±0.5%
DC voltage adjustment±10%±10%±10%±10%
AC input85–264 VAC
DC input120–370 VDC
Dimensions40 × 125.2 × 113.5 mm
Family power class120 W (single output)
Input frequency47–63 Hz
Cold-start inrush30 A at 115 VAC; 60 A at 230 VAC
Overload protection105–150%: output cutoff; automatic recovery.
Overvoltage protection120–140%: output shuts down. Reapply power to recover.
Setup / rise / hold-up1200 / 60 / 60 ms at 230 VAC, full load.
Withstand voltageInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV; 1 minute.
Insulation resistanceInput/output, input/FG and output/FG: 100 MΩ at 500 VDC.
Working environment−10 to +50 °C
Unit weight0.6 kg
Packing45.5 × 35 × 26 cm
Output options
ModelOutputCurrentEfficiency
NDR-120-1212 V0–10 A86%
NDR-120-1515 V0–8 A88%
NDR-120-2424 V0–5 A88%
NDR-120-4848 V0–2.5 A89%
Additional model specifications
NDR-120-12
Ripple and noise100 mV p-p
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
NDR-120-15
Ripple and noise120 mV p-p
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
NDR-120-24
Ripple and noise120 mV p-p
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
NDR-120-48
Ripple and noise150 mV p-p
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Common specifications
AC input85–264 VAC
DC input120–370 VDC
Dimensions40 × 125.2 × 113.5 mm
Family power class120 W (single output)
Input frequency47–63 Hz
Cold-start inrush30 A at 115 VAC; 60 A at 230 VAC
Overload protection105–150%: output cutoff; automatic recovery.
Overvoltage protection120–140%: output shuts down. Reapply power to recover.
Setup / rise / hold-up1200 / 60 / 60 ms at 230 VAC, full load.
Withstand voltageInput/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV; 1 minute.
Insulation resistanceInput/output, input/FG and output/FG: 100 MΩ at 500 VDC.
Working environment−10 to +50 °C
Unit weight0.6 kg
Packing45.5 × 35 × 26 cm

Dimensions & technical notes

Mechanical dimensions

40 × 125.2 × 113.5 mm

Side elevation
NDR-120 side elevation from the WEHO drawing.

Side elevation from the model sheet; dimensions in mm.

Front elevation
NDR-120 front elevation from the WEHO drawing.

Front elevation from the model sheet; dimensions in mm.

Top view
NDR-120 top view from the WEHO drawing.

Top view from the model sheet; dimensions in mm.

Bottom view
NDR-120 bottom view from the WEHO drawing.

Bottom view from the model sheet; dimensions in mm.

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +.

TB2: 4 and 5 = −V; 6 and 7 = +V.

Product overview

Use NDR-120 where the panel needs one DC voltage. For example, NDR-120-12 provides 12 V at 0–10 A, while NDR-120-48 provides 48 V at 0–2.5 A. Compare the actual load profile, not the suffix alone.

Design features

FeatureWhat to check
Output selection12 V, 15 V, 24 V or 48 V; choose one version for the required DC rail.
Input and restartAt cold start the input draws 30 A at 115 VAC; 60 A at 230 VAC. This transient is not available to the DC load.
Cabinet environment−10 to +50 °C. Check the intended load at the actual ambient temperature.

Installation & applications

Installation checks

Reserve space on the rail for NDR-120.

Reserve space on the rail

The sheet lists 40 × 125.2 × 113.5 mm. Check terminal access and cable bends separately; the enclosure dimension is not an installation clearance.

Identify the terminal blocks for NDR-120.

Identify the terminal blocks

TB1: 1 = FG; 2 = AC/N or DC −; 3 = AC/L or DC +. TB2: 4 and 5 = −V; 6 and 7 = +V. Verify the markings on the unit before connecting power.

Check cabinet temperature for NDR-120.

Check cabinet temperature

−10 to +50 °C. Check the air temperature at the supply under the intended cabinet load. The temperature interval alone does not rate full output at its upper limit.

Allow for input inrush for NDR-120.

Allow for input inrush

The sheet gives 30 A at 115 VAC; 60 A at 230 VAC. Compare the applicable input condition with upstream protection; these are not DC load-current ratings.

Application examples

A print-and-apply head sits beside the vertical face of a brown carton, next to a roll of label stock.

Applying a label to a carton

A carton sensor can trigger the applicator as the box reaches the head. Include the sensor and DC control inputs; size a print engine or pneumatic actuator separately. For an external 24 V DC input, compare total running and peak demand with NDR-120-24 (0–5 A).

Photo: Robert Luther — 4051 lpa.jpg · Public domain · Converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
Small-part storage aisles rise behind the handling stations of an automated warehouse.

Retrieving parts from high-bay shelving

A bin-presence input can confirm that a tote has reached the retrieval station before the next transfer. The input module and sensors form a different load from the aisle crane. For an external 24 V DC input, compare total running and peak demand with NDR-120-24 (0–5 A).

Photo: Andreas Praefcke — Automatisches Kleinteilelager.jpg · CC BY 3.0 · Converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
Stretch film surrounds a pallet of cartons on a wrapping turntable.

Following a pallet as film is applied

A height sensor can tell the film carriage where the top of a pallet load is. Check the sensor and carriage-control inputs rather than treating the turntable motor as a DC control load. For an external 24 V DC input, compare total running and peak demand with NDR-120-24 (0–5 A).

Photo: heb @ Wikimedia Commons — Pallet wrapper.jpg · CC BY-SA 3.0 · Resized and converted to WebP; full frame. Illustrative only; no endorsement or verified installation.
An outdoor pneumatic-tube terminal stands beneath the canopy of a drive-through bank.

Signalling arrival at a carrier terminal

At a carrier terminal, an arrival switch can light an indicator for the attendant. Check the combined indicator and interface load; the air blower has its own supply. For an external 24 V DC input, compare total running and peak demand with NDR-120-24 (0–5 A).

Photo: Hustvedt — Bank pneumatic tubes.jpg · CC BY-SA 3.0 · Resized and converted to WebP; full frame. Illustrative only; no endorsement or verified installation.

Application images are illustrations of possible DC loads, not customer installations or verified equipment pairings.

Frequently asked questions

Which outputs are available?

The WEHO sheet lists 12 V, 15 V, 24 V or 48 V. These are separate orderable versions, not four outputs from one supply.

What current does the 24 V version supply?

NDR-120-24 is listed at 0–5 A. Include all loads that operate together; check startup demand separately.

What input range should I specify?

The NDR-120 sheet lists 85–264 VAC at 47–63 Hz, or 120–370 VDC. State which supply will be present at the panel.

What happens after a fault?

105–150%: output cutoff; automatic recovery. Overvoltage: 120–140%: output shuts down. Reapply power to recover.

How should I check cabinet fit?

The sheet lists 40 × 125.2 × 113.5 mm. Allow space for the cable bend and access to the terminal blocks.

What information is useful for a quotation?

Give the full suffix (for example, NDR-120-24), input source, running and startup current, cabinet temperature, quantity and destination.

Temperature derating

The NDR-120 company datasheet specifies a working temperature of −10 to +50 °C. It does not give a load-versus-temperature curve for these output versions. Do not treat the upper ambient limit as a full-load rating.

For a continuous-duty installation, state the selected output, maximum cabinet temperature, mounting position and expected load when requesting a confirmed operating point.

Send Inquiry

Tell us how many units you need and where they will be delivered.

NDR-120-24 sample, oblique view.
NDR-120-24 · photographed sample
Selected model
NDR-120-12NDR-120-15NDR-120-24NDR-120-48
DC output
12 V · 0–10 A15 V · 0–8 A24 V · 0–5 A48 V · 0–2.5 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.