S-350W series normal single switching power supply

WEHO S-350 is a single-output power-supply family for machine builders assessing a local DC rail for interface, job-memory and status electronics. S-350 has separate 5V, 9V, 12V, 15V, 18V and 24V output variants. The listed body dimensions are 215×115×50mm. AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. The documented 9V and 18V choices require explicit suffix selection. Treat the printed current and timing entries as selection evidence, then confirm continuous duty, wiring and actual cooling for the intended electronic load before ordering.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

S-350-12 specimen

Original view shown; no verified upright photograph of this version.

S-350 Series Single-Output Switching Power Supply

Select one of 6 single-output versions. Compare the current and ripple at the voltage your load needs.

Select output voltage
Model
S-350-5S-350-9S-350-12S-350-15S-350-18S-350-24
DC output
5 V · 0–50 A9 V · 0–38 A12 V · 0–29 A15 V · 0–23.3 A18 V · 0–19.4 A24 V · 0–14.6 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
Efficiency
73%78%83%83%84%85%
Dimensions (L × W × H)
215 × 115 × 50 mm

Specifications & models

ParameterS-350-5S-350-9S-350-12S-350-15S-350-18S-350-24
DC output voltage and current5 V · 0–50 A9 V · 0–38 A12 V · 0–29 A15 V · 0–23.3 A18 V · 0–19.4 A24 V · 0–14.6 A
Efficiency73%78%83%83%84%85%
Ripple and noise150 mV p-p150 mV p-p150 mV p-p150 mV p-p150 mV p-p150 mV p-p
Line regulation±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load regulation±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
DC voltage adjustment±10%±10%±10%±10%±10%±10%
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush25 A at 115 V AC; 50 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protection115–150%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)215 × 115 × 50 mm
Unit weight1 kg
Packing45.5 × 31.5 × 26 cm; 20 units/carton; 20 kg/carton
Output options
OutputCurrentEfficiencyRipple
5 V0–50 A73%150 mV p-p
9 V0–38 A78%150 mV p-p
12 V0–29 A83%150 mV p-p
15 V0–23.3 A83%150 mV p-p
18 V0–19.4 A84%150 mV p-p
24 V0–14.6 A85%150 mV p-p
Additional model specifications
S-350-5
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-350-9
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-350-12
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-350-15
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-350-18
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-350-24
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Common specifications
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush25 A at 115 V AC; 50 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protection115–150%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)215 × 115 × 50 mm
Unit weight1 kg
Packing45.5 × 31.5 × 26 cm; 20 units/carton; 20 kg/carton

Dimensions & technical notes

Mechanical dimensions

215 × 115 × 50 mm (L × W × H)

Wide face
S-350 wide face, dimensioned in millimetres
Narrow face
S-350 narrow face, dimensioned in millimetres

Dimensions in millimetres. The source groups the AC input pins. Check L and N on the unit; the legend does not identify them individually.

The 135 mm dimension spans the mounting-ear hole centres. It is not the 115 mm body width.

Product overview

S-350 is a single-output enclosed supply. The S-350-5 and S-350-24 are separate units, not two settings on the same unit. Select the AC band that matches the installation. The two bands are not one continuous input range.

Design features

FeatureWhat to check
Input selectionSelect the AC band that matches the installation. The two bands are not one continuous input range.
Timing at full load200 / 50 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingThe 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.

Installation & applications

Installation checks

Illustrative current budget: 10 board fixtures at 2.8 A each versus the 50 A listed limit.

Budget the board fixtures together

If 10 board fixtures each draw 2.8 A, their running load is 28 A. The S-350-5 lists 50 A at 5 V DC. Allow for boot peaks and program the fixture sequence for the maximum installed board count. Check peak demand and available output at the installed temperature.

S-350 body plan, 215 by 115 mm, with 50 mm table height. The adjacent load is a separate access sketch.

Allow for the body and service access

The body measures 215 × 115 × 50 mm. The 135 mm mounting-hole span is not the body width. Keep the fixture harness loops clear of the supply and of the hinge's full sweep.

Optical check for the illuminated magnifier: magnifier working distance.

Set the lens and illumination together

Place a representative solder joint at the working height. Adjust the light and lens so the joint is visible without glare before checking full-output current.

Capture a cycle for the relay scanner: scanner settle time.

Check relay settling before readings

Record the switching interval and wait for the measuring path to settle before sampling resistance. A coil being energized does not prove its contacts have settled.

Application examples

Match the S-350 output voltage and available current to the device shown. Each scene illustrates a separate DC load.

A hinged test fixture holds three green controller boards beneath rows of spring probes.

Testing controller boards in parallel

A 5 V rail powers populated controller boards in a bed-of-nails fixture. Budget simultaneous board boot and protect each fixture branch; programming and signal references are separate design decisions.

An illuminated magnifying lens enlarges the pins and solder joints on a circuit board.

Reading a PCB through a magnifier

A 12 V-rated magnifier head lights solder joints beneath its lens. Use its driver input rating at full output; the board under inspection need not be energized.

A bank of clear relays sits beside a probe fixture and a bench meter.

Scanning resistance test points

The 24 V relay scanner selects probe pairs for a separate ohmmeter. Check coil demand for the scanner's actual switching pattern; its contact ratings are not supply-current ratings.

Coloured probe leads connect a logic acquisition pod to a board beside a screen with stepped traces.

Capturing logic transitions

Select a pod with a separate 5 V DC power input. Its probes sample logic-level signals; confirm the allowed probe voltage and do not tie the supply output to signal pins.

AI-generated application illustrations, not customer installation photographs or wiring diagrams.

Frequently asked questions

Which outputs can I specify for S-350?

The standard sheet lists 5 V, 9 V, 12 V, 15 V, 18 V, 24 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.

What space should I allow?

The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.

What happens on overload?

105–135%. Output shuts off; automatic recovery.

Are special outputs included in this selector?

No. The 27, 36, 48, 60, 70 and 110 V special edition has its own download in the datasheet reader. Its 110 V upper-current cell is malformed (0~3..2 A); request confirmation rather than assuming a value.

S-350-12 specimen · terminal end, cover and side, three-quarter

WEHO S-350-12 power supply — terminal end, cover and side, three-quarter

S-350-12 specimen

WEHO S-350-12 power supply — terminal-facing front and cover

S-350-12 specimen · terminal-facing front and cover

WEHO S-350-12 power supply — terminal-facing front and cover

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO S-350-12 power supply — terminal end, cover and side, three-quarter
S-350-12 specimen
Selected model
S-350-5S-350-9S-350-12S-350-15S-350-18S-350-24
DC output
5 V · 0–50 A9 V · 0–38 A12 V · 0–29 A15 V · 0–23.3 A18 V · 0–19.4 A24 V · 0–14.6 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.