MDR series ac 220v to dc power supply 10w switching power supply

MDR-10 is a slim line DIN rail Class I switching power supply.
Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.If you have any questions, please do not hesitate to contact us at Email: [email protected]

Photographed sample: MDR-10-5

MDR-10 Single-Output DIN Rail Power Supply

Compare four low-current DC outputs for sensing and indication in a 22.5 mm rail position.

Select output voltage
Model
MDR-10-5MDR-10-12MDR-10-15MDR-10-24
DC output
5 V · 0–2 A12 V · 0–0.84 A15 V · 0–0.6 A24 V · 0–0.42 A
AC input
85–264 VAC
DC input
120–370 VDC
Efficiency
77%81%82%84%
Dimensions (W × H × D)
22.5 × 90 × 100 mm

Specifications & models

ParameterMDR-10-5MDR-10-12MDR-10-15MDR-10-24
DC output voltage and current5 V · 0–2 A12 V · 0–0.84 A15 V · 0–0.6 A24 V · 0–0.42 A
Efficiency77%81%82%84%
Ripple and noise80 mV p-p120 mV p-p120 mV p-p150 mV p-p
Line regulation±1%±1%±1%±1%
Load regulation±1%±1%±1%±1%
DC voltage adjustment±2%±1%±1%±1%
5 V signal: minimum R200 Ω1.5 kΩ2 kΩ3.9 kΩ
LED example: minimum R1 kΩ2.4 kΩ3 kΩ4.7 kΩ
Relay example: minimum RL120 Ω700 Ω700 Ω1.2 kΩ
AC input85–264 VAC
DC input120–370 VDC
Dimensions (W × H × D)22.5 × 90 × 100 mm
Input frequency47–63 Hz
Cold-start inrush35 A at 115 VAC; 70 A at 230 VAC
Overload protection105–160%; output cuts off and recovers automatically.
Overvoltage protection120–140%; output shuts down. Cycle input power to recover.
Setup / rise at full load500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC.
Hold-up timeNot specified.
Withstand voltage (1 min)Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV.
Insulation resistance100 MΩ at 500 VDC: input/output, input/FG and output/FG.
Working temperature−10 °C to +50 °C
Mounting railTS35/7.5 or TS35/15
Unit weight0.17 kg
Packing45.5 × 31.5 × 23 cm / 90 pcs / 16 kg
Output options
ModelOutputCurrentEfficiency
MDR-10-55 V0–2 A77%
MDR-10-1212 V0–0.84 A81%
MDR-10-1515 V0–0.6 A82%
MDR-10-2424 V0–0.42 A84%
Additional model specifications
MDR-10-5
Ripple and noise80 mV p-p
Line regulation±1%
Load regulation±1%
DC voltage adjustment±2%
5 V signal: minimum R200 Ω
LED example: minimum R1 kΩ
Relay example: minimum RL120 Ω
MDR-10-12
Ripple and noise120 mV p-p
Line regulation±1%
Load regulation±1%
DC voltage adjustment±1%
5 V signal: minimum R1.5 kΩ
LED example: minimum R2.4 kΩ
Relay example: minimum RL700 Ω
MDR-10-15
Ripple and noise120 mV p-p
Line regulation±1%
Load regulation±1%
DC voltage adjustment±1%
5 V signal: minimum R2 kΩ
LED example: minimum R3 kΩ
Relay example: minimum RL700 Ω
MDR-10-24
Ripple and noise150 mV p-p
Line regulation±1%
Load regulation±1%
DC voltage adjustment±1%
5 V signal: minimum R3.9 kΩ
LED example: minimum R4.7 kΩ
Relay example: minimum RL1.2 kΩ
Common specifications
AC input85–264 VAC
DC input120–370 VDC
Dimensions (W × H × D)22.5 × 90 × 100 mm
Input frequency47–63 Hz
Cold-start inrush35 A at 115 VAC; 70 A at 230 VAC
Overload protection105–160%; output cuts off and recovers automatically.
Overvoltage protection120–140%; output shuts down. Cycle input power to recover.
Setup / rise at full load500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC.
Hold-up timeNot specified.
Withstand voltage (1 min)Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV.
Insulation resistance100 MΩ at 500 VDC: input/output, input/FG and output/FG.
Working temperature−10 °C to +50 °C
Mounting railTS35/7.5 or TS35/15
Unit weight0.17 kg
Packing45.5 × 31.5 × 23 cm / 90 pcs / 16 kg

Dimensions & technical notes

Mechanical dimensions

22.5 × 90 × 100 mm (W × H × D)

Front view
MDR-10 front view: 22.5 mm wide and 90 mm high.

Housing: 22.5 mm wide × 90 mm high.

Side view
MDR-10 side view: 100 mm deep, excluding field wiring.

Housing depth: 100 mm. Allow extra room for field wiring.

Mounting rail
Mounting rail: 35 mm wide. This is the rail width, not the housing width.

35 mm rail width. Fits TS35/7.5 or TS35/15.

Terminal groups: 1 and 2 — AC input; 3 — ground; 4 — DC positive; 5 — DC negative; 6 — DC OK. Follow the markings on the actual unit. Do not infer DC-input polarity from the AC labels.

DC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating.

Product overview

The 15 V model supplies 0–0.6 A. A sensor that requires more than 0.6 A at startup needs a different selection.

The MDR-10 brings a regulated DC branch and external signal circuits to the rail. Choose the output from the load label, then use its own column for current, ripple and efficiency.

Design features

FeatureWhat to check
Voltage selectionChoose a fixed output suffix before comparing current ranges.
Status monitoringDC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating.
Service accessAllow for the 22.5 × 90 × 100 mm body plus wiring and access to the voltage trim.
Power budgetThe 15 V model supplies 0–0.6 A. A sensor that requires more than 0.6 A at startup needs a different selection.

The photo identifies one specimen; electrical data on this page come from the WEHO model sheet.

Installation & applications

Installation checks

Illustrative scenes only; the waveform is not a product test result.

Steel square beside an empty DIN rail between two wiring ducts.

Check the rail position

Allow for the 22.5 × 90 × 100 mm housing on TS35/7.5 or TS35/15 rail. The drawing dimensions exclude the cable bend and working space.

A scanner beside a carton marked MDR-10-5 for an ordering-suffix check.

Identify the output before connection

For the MDR-10-5, verify the complete model suffix on the unit. With power isolated, check the full suffix and terminal markings on the unit being installed. A different output choice is a different version.

Proximity sensor, indicator lamp and relay beside a calculator for a DC load budget.

Budget the DC load

For MDR-10-24, the printed current range is 0–0.42 A. Add the branch loads that can start together; do not substitute input inrush for DC capacity.

Oscilloscope with an illustrative startup pulse and a current probe on the bench.

Check cold-start inrush

The input inrush is 35 A at 115 VAC; 70 A at 230 VAC. Check the upstream protection at the corresponding input voltage, separately from output current.

Application examples

A gloved hand reaches toward the weighing chamber of a blue analytical balance on a laboratory bench.

Weighing a solid sample

For a balance specified for an external 5 V DC input, compare its peak current with the MDR-10-5 range (0–2 A). Confirm connector polarity and the permitted ripple before changing its supply.

Photo: Giovanna Canu, Francesca Cirisano, Sofia Gambaro, CNR-ICMATE · CC BY 4.0
“Measuring density”: cropped, resized and converted to WebP.
A thermostatic water bath on a laboratory bench, with the temperature display and controls on the right.

Monitoring a water bath

A separate 12 V DC panel meter can display bath temperature from a matching probe. Check the meter’s input and current against MDR-10-12 (0–0.84 A); the bath heater needs its own supply.

Photo: Adimora chidinma · CC0 1.0
Cropped and converted to WebP.
Three self-service library checkout stations stand in a row beside the windows.

Checking out tagged library books

At a self-check station, an RFID reader identifies tagged books. For a separately powered 5 V DC reader, compare peak scanning current with MDR-10-5 (0–2 A). A USB-only reader still needs its specified host.

Photo: Löwenmaus27 · CC BY 4.0
Cropped and converted to WebP.
A drink machine has selection buttons under its shelves and a second numbered keypad beside the pickup hatch.

Selecting a drink at a vending machine

For a 24 V DC selection panel, add the current of its input electronics and all indicators that can light together. Compare that total and startup demand with MDR-10-24 (0–0.42 A), excluding the vend motor and refrigeration.

Photo: Nelo Hotsuma · CC BY 2.0
Cropped and converted to WebP.

These photographs show where low-voltage loads are used. They do not show verified MDR-10 installations or imply endorsement. Match the actual component’s specified input before choosing a supply.

Frequently asked questions

Can I switch between the listed output voltages on one unit?

No. Each column identifies a separate single-output version. For example, MDR-10-12 is the 12 V model and MDR-10-24 is the 24 V model. The trim adjustment is not a voltage selector.

Which current range applies to the 24 V model?

MDR-10-24 is specified at 0–0.42 A. Include simultaneous loads and startup demand when sizing the branch.

What are the AC and DC input ranges?

The MDR-10 datasheet specifies 85–264 VAC and 120–370 VDC. The 47–63 Hz frequency range applies to AC.

Which rail and enclosure dimensions should I use?

The housing measures 22.5 × 90 × 100 mm. The manufacturer drawing lists TS35/7.5 or TS35/15; reserve extra space for cable access.

How is DC OK used?

DC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating.

Does the upper temperature limit imply full load?

No. The sheet lists −10 °C to +50 °C as the working range; it does not establish full load at every ambient temperature. Check the actual enclosure conditions.

How does the output recover after a fault?

Overload cuts off output with automatic recovery. Overvoltage shuts down the output; cycle input power after the fault is cleared.

Is a hold-up time specified?

500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. These are full-load setup and rise times. No separate hold-up value is printed.

How large is the input surge?

35 A at 115 VAC; 70 A at 230 VAC are the two cold-start input conditions. Coordinate upstream protection for the actual input and number of supplies starting together.

What is the ripple figure for the 12 V output?

MDR-10-12 lists 120 mV p-p. Check the ripple tolerance at the load as well as the DC current requirement.

What is the insulation test stated on the sheet?

Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. These one-minute withstand figures are not continuous operating voltages.

What information helps specify a replacement?

Give the full MDR-10 suffix, DC load and startup demand, installed rail and available space. A match in family wattage or cabinet width does not establish interchangeability.

Service conditions

Working temperature
−10 °C to +50 °C ambient; this range does not establish continuous full load at its upper limit.
Startup
500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. No hold-up time is specified.
Upstream protection
Use the cold-start inrush figure for the actual input: 35 A at 115 VAC; 70 A at 230 VAC.
Installation space
Check the rail fit and keep terminals and voltage trim accessible; the printed dimensions describe the unit, not the cabinet clearance.

Send Inquiry

Tell us how many units you need and where they will be delivered.

MDR-10-5 WEHO sample, front and right side
Photographed sample: MDR-10-5
Selected model
MDR-10-5MDR-10-12MDR-10-15MDR-10-24
DC output
5 V · 0–2 A12 V · 0–0.84 A15 V · 0–0.6 A24 V · 0–0.42 A