Check the rail position
Allow for the 22.5 × 90 × 100 mm housing on TS35/7.5 or TS35/15 rail. The drawing dimensions exclude the cable bend and working space.
MDR-20 is a slim line DIN rail Class I switching power supply.
Designed with a fully isolated plastic case to prevent user contact and the risk of shock.Featuring up to 88% efficiency this series can be cooled using only free air convection up to 60°C which significantly increases the reliability and lifetime of the power supply.Other standard features include its low no-load power consumption, to save energy, short circuit, overload, and over voltage protections, and DC OK relay contact with LED indicator for monitoring the PSU status.If you have any questions, please do not hesitate to contact us at Email: [email protected]
Choose among four fixed output versions in the same 22.5 mm-wide housing. Check the current for the selected voltage.
| Parameter | MDR-20-5 | MDR-20-12 | MDR-20-15 | MDR-20-24 |
|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–3 A | 12 V · 0–1.67 A | 15 V · 0–1.34 A | 24 V · 0–1 A |
| Efficiency | 76% | 80% | 81% | 84% |
| Ripple and noise | 80 mV p-p | 120 mV p-p | 120 mV p-p | 150 mV p-p |
| Line regulation | ±1% | ±1% | ±1% | ±1% |
| Load regulation | ±1% | ±1% | ±1% | ±1% |
| DC voltage adjustment | ±2% | ±1% | ±1% | ±1% |
| 5 V signal: minimum R | 200 Ω | 1.5 kΩ | 2 kΩ | 3.9 kΩ |
| LED example: minimum R | 1 kΩ | 2.4 kΩ | 3 kΩ | 4.7 kΩ |
| Relay example: minimum RL | 120 Ω | 700 Ω | 700 Ω | 1.2 kΩ |
| AC input | 85–264 VAC | |||
| DC input | 120–370 VDC | |||
| Dimensions (W × H × D) | 22.5 × 90 × 100 mm | |||
| Input frequency | 47–63 Hz | |||
| Cold-start inrush | 20 A at 115 VAC; 40 A at 230 VAC | |||
| Overload protection | 105–160%; output cuts off and recovers automatically. | |||
| Overvoltage protection | 120–140%; output shuts down. Cycle input power to recover. | |||
| Setup / rise at full load | 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. | |||
| Hold-up time | Not specified. | |||
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. | |||
| Insulation resistance | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. | |||
| Working temperature | −10 °C to +50 °C | |||
| Mounting rail | TS35/7.5 or TS35/15 | |||
| Unit weight | 0.19 kg | |||
| Packing | 45.5 × 31.5 × 23 cm / 90 pcs / 18 kg | |||
| Model | Output | Current | Efficiency |
|---|---|---|---|
| MDR-20-5 | 5 V | 0–3 A | 76% |
| MDR-20-12 | 12 V | 0–1.67 A | 80% |
| MDR-20-15 | 15 V | 0–1.34 A | 81% |
| MDR-20-24 | 24 V | 0–1 A | 84% |
| Ripple and noise | 80 mV p-p |
|---|---|
| Line regulation | ±1% |
| Load regulation | ±1% |
| DC voltage adjustment | ±2% |
| 5 V signal: minimum R | 200 Ω |
| LED example: minimum R | 1 kΩ |
| Relay example: minimum RL | 120 Ω |
| Ripple and noise | 120 mV p-p |
|---|---|
| Line regulation | ±1% |
| Load regulation | ±1% |
| DC voltage adjustment | ±1% |
| 5 V signal: minimum R | 1.5 kΩ |
| LED example: minimum R | 2.4 kΩ |
| Relay example: minimum RL | 700 Ω |
| Ripple and noise | 120 mV p-p |
|---|---|
| Line regulation | ±1% |
| Load regulation | ±1% |
| DC voltage adjustment | ±1% |
| 5 V signal: minimum R | 2 kΩ |
| LED example: minimum R | 3 kΩ |
| Relay example: minimum RL | 700 Ω |
| Ripple and noise | 150 mV p-p |
|---|---|
| Line regulation | ±1% |
| Load regulation | ±1% |
| DC voltage adjustment | ±1% |
| 5 V signal: minimum R | 3.9 kΩ |
| LED example: minimum R | 4.7 kΩ |
| Relay example: minimum RL | 1.2 kΩ |
| AC input | 85–264 VAC |
|---|---|
| DC input | 120–370 VDC |
| Dimensions (W × H × D) | 22.5 × 90 × 100 mm |
| Input frequency | 47–63 Hz |
| Cold-start inrush | 20 A at 115 VAC; 40 A at 230 VAC |
| Overload protection | 105–160%; output cuts off and recovers automatically. |
| Overvoltage protection | 120–140%; output shuts down. Cycle input power to recover. |
| Setup / rise at full load | 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. |
| Hold-up time | Not specified. |
| Withstand voltage (1 min) | Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. |
| Insulation resistance | 100 MΩ at 500 VDC: input/output, input/FG and output/FG. |
| Working temperature | −10 °C to +50 °C |
| Mounting rail | TS35/7.5 or TS35/15 |
| Unit weight | 0.19 kg |
| Packing | 45.5 × 31.5 × 23 cm / 90 pcs / 18 kg |
22.5 × 90 × 100 mm

Width and height are dimensioned on the front view.

Depth is dimensioned on the side view; it does not include field wiring.

Rail profile from the model sheet. Mounting types: TS35/7.5 and TS35/15.
Terminal groups: 1 and 2 — AC input; 3 — ground; 4 — DC positive; 5 — DC negative; 6 — DC OK. Follow the markings on the actual unit. Do not infer DC-input polarity from the AC labels.
DC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating.
The 20 W heading identifies the family. For the 24 V version use its own printed 0–1 A range, not a current calculated from the heading.
The MDR-20 brings a regulated DC branch and external signal circuits to the rail. Choose the output from the load label, then use its own column for current, ripple and efficiency.
| Feature | What to check |
|---|---|
| Voltage selection | Choose a fixed output suffix before comparing current ranges. |
| Status monitoring | DC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating. |
| Service access | Allow for the 22.5 × 90 × 100 mm body plus wiring and access to the voltage trim. |
| Power budget | The 20 W heading identifies the family. For the 24 V version use its own printed 0–1 A range, not a current calculated from the heading. |
The photo identifies one specimen; electrical data on this page come from the WEHO model sheet.
Allow for the 22.5 × 90 × 100 mm housing on TS35/7.5 or TS35/15 rail. The drawing dimensions exclude the cable bend and working space.
The photograph identifies MDR-20-24. With power isolated, check the full suffix and terminal markings on the unit being installed. A different output choice is a different version.
For MDR-20-24, the printed current range is 0–1 A. Add the branch loads that can start together; do not substitute input inrush for DC capacity.
The input inrush is 20 A at 115 VAC; 40 A at 230 VAC. Check the upstream protection at the corresponding input voltage, separately from output current.

Transmitted light makes the specimen visible through the objective. For an illuminator with a 12 V DC driver input, check the driver’s peak demand against MDR-20-12 (0–1.67 A). Do not connect a bare LED directly.
Photo: Waughd · CC BY-SA 4.0
A queue display tells visitors which counter to approach. If the display controller takes 24 V DC, compare its maximum current, including the display at full brightness, with MDR-20-24 (0–1 A). Exclude the ticket printer.
Photo: HnoocppK 223 · CC0 1.0
Consider MDR-20-12 (0–1.67 A) only for an effects pedal marked for 12 V DC. Match polarity and check the noise and isolation requirements; a 9 V-only pedal needs a different supply.
Photo: Shixart1985 · CC BY 2.0
The reader senses a passenger’s card and reports it to the fare system. For a separately powered 12 V DC reader, check peak read current against MDR-20-12 (0–1.67 A). The gate mechanism is a separate load.
Photo: Hahifuheho · CC0 1.0These photographs show examples of low-voltage loads, not verified MDR-20 installations or endorsements. Check the actual component’s input specification before selecting a supply.
No. Each column identifies a separate single-output version. For example, MDR-20-12 is the 12 V model and MDR-20-24 is the 24 V model. The trim adjustment is not a voltage selector.
MDR-20-24 is specified at 0–1 A. Include simultaneous loads and startup demand when sizing the branch.
The MDR-20 datasheet specifies 85–264 VAC and 120–370 VDC. The 47–63 Hz frequency range applies to AC.
The housing measures 22.5 × 90 × 100 mm. The manufacturer drawing lists TS35/7.5 or TS35/15; reserve extra space for cable access.
DC OK is a signal terminal. The signal, LED and external relay examples use different minimum resistances; the relay example is not an internal dry-contact rating.
No. The sheet lists −10 °C to +50 °C as the working range; it does not establish full load at every ambient temperature. Check the actual enclosure conditions.
Overload cuts off output with automatic recovery. Overvoltage shuts down the output; cycle input power after the fault is cleared.
500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. These are full-load setup and rise times. No separate hold-up value is printed.
20 A at 115 VAC; 40 A at 230 VAC are the two cold-start input conditions. Coordinate upstream protection for the actual input and number of supplies starting together.
MDR-20-12 lists 120 mV p-p. Check the ripple tolerance at the load as well as the DC current requirement.
Input/output: 1.5 kV; input/FG: 1.5 kV; output/FG: 0.5 kV. These one-minute withstand figures are not continuous operating voltages.
Give the full MDR-20 suffix, DC load and startup demand, installed rail and available space. A match in family wattage or cabinet width does not establish interchangeability.



This view shows MDR-20-24; the photographed unit does not change when another output is selected. Electrical specifications follow the MDR-20 datasheet.

A crop of the pictured specimen for identification, not a separate specification source.

Width and height are dimensioned on the front view.

Depth is dimensioned on the side view; it does not include field wiring.

Rail profile from the model sheet. Mounting types: TS35/7.5 and TS35/15.