Check start-up demand
Compare the load’s running current with the selected S-250 column. Include its start-up current and duration in your request; the overload threshold is not a continuous rating.
WEHO S-250 is a single-output supply family for builders comparing local DC power options for machine interfaces and communication electronics. S-250 has separate 5V, 12V, 15V, 24V, 36V and 48V output variants. The listed body dimensions are 215×115×50mm. AC input is 90~132VAC/180~264VAC by switch; the same input row also lists 254~370VDC and 47~63Hz. Its suffix-specific current, ripple and stability entries are useful when the same machine platform contains different electronic board sets. Specify the required output, real load duty and installed thermal arrangement before ordering; the family number alone is not an output-selection rule.
If you have any questions, please do not hesitate to contact us at Email: [email protected]
Select one of 6 single-output versions. Compare the current and ripple at the voltage your load needs.
| Parameter | S-250-5 | S-250-12 | S-250-15 | S-250-24 | S-250-36 | S-250-48 |
|---|---|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–45 A | 12 V · 0–20 A | 15 V · 0–16 A | 24 V · 0–10 A | 36 V · 0–6.7 A | 48 V · 0–5 A |
| Efficiency | 74% | 79% | 79% | 81.5% | 84% | 84% |
| Ripple and noise | 150 mV p-p | 150 mV p-p | 150 mV p-p | 150 mV p-p | 200 mV p-p | 240 mV p-p |
| Line regulation | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Load regulation | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
| DC voltage adjustment | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
| Input voltage | 90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz | |||||
| Cold-start inrush | 25 A at 115 V AC; 50 A at 230 V AC | |||||
| Overload protection | 105–135%. Output shuts off; automatic recovery. | |||||
| Overvoltage protection | 115–150%. Output shuts off; cycle input power to recover. | |||||
| Setup / rise / hold-up | 200 / 50 / 16 ms at 230 V AC, full load | |||||
| Withstand voltage | Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min) | |||||
| Insulation resistance | 100 MΩ at 500 V DC: input-output, input-FG, output-FG | |||||
| Operating temperature | -10 to 50 °C | |||||
| Dimensions (L × W × H) | 215 × 115 × 50 mm | |||||
| Unit weight | 0.95 kg | |||||
| Packing | 45.5 × 31.5 × 26 cm; 20 units/carton; 19 kg/carton | |||||
| Output | Current | Efficiency | Ripple |
|---|---|---|---|
| 5 V | 0–45 A | 74% | 150 mV p-p |
| 12 V | 0–20 A | 79% | 150 mV p-p |
| 15 V | 0–16 A | 79% | 150 mV p-p |
| 24 V | 0–10 A | 81.5% | 150 mV p-p |
| 36 V | 0–6.7 A | 84% | 200 mV p-p |
| 48 V | 0–5 A | 84% | 240 mV p-p |
| Line regulation | ±2% |
|---|---|
| Load regulation | ±2% |
| DC voltage adjustment | ±10% |
| Line regulation | ±1% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Line regulation | ±1% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Line regulation | ±1% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Line regulation | ±1% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Line regulation | ±1% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Input voltage | 90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz |
|---|---|
| Cold-start inrush | 25 A at 115 V AC; 50 A at 230 V AC |
| Overload protection | 105–135%. Output shuts off; automatic recovery. |
| Overvoltage protection | 115–150%. Output shuts off; cycle input power to recover. |
| Setup / rise / hold-up | 200 / 50 / 16 ms at 230 V AC, full load |
| Withstand voltage | Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min) |
| Insulation resistance | 100 MΩ at 500 V DC: input-output, input-FG, output-FG |
| Operating temperature | -10 to 50 °C |
| Dimensions (L × W × H) | 215 × 115 × 50 mm |
| Unit weight | 0.95 kg |
| Packing | 45.5 × 31.5 × 26 cm; 20 units/carton; 19 kg/carton |

The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width. The full-load condition applies to the timing test, not to the entire operating temperature range.
| Feature | What to check |
|---|---|
| Input selection | Select the AC band that matches the installation. The two bands are not one continuous input range. |
| Timing at full load | 200 / 50 / 16 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range. |
| Case and mounting | The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width. |
Source: WEHO S-250.pdf, p. 1 (original bilingual sheet); R1, pp. 1–2 (English ratings and original mechanical drawing).
Compare the load’s running current with the selected S-250 column. Include its start-up current and duration in your request; the overload threshold is not a continuous rating.
The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.
Terminal-facing front and cover. Specimen input marking: 115 VAC 5 A / 230 VAC 2.5 A, 50/60 Hz. Output marking: 24 V DC / 10 A. The 115/230 V notice and selector window are on the vented long side. The output adjustment at the terminal end is a different control.
The standard sheet lists 5 V, 12 V, 15 V, 24 V, 36 V, 48 V. Order the full suffix for the required output; the selector compares different units.
90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.
The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width.
105–135%. Output shuts off; automatic recovery.
The 135 mm dimension is the distance between mounting-ear hole centres, not the 115 mm case width. The full-load condition applies to the timing test, not to the entire operating temperature range.