S-50W series normal single switching power supply

WEHO S-50 is a 50W-designated single-output family for compatible equipment-control, display and interface electronics, with separate 5V, 12V, 15V and 24V options in a 159×98×38mm enclosure. Input is 90~132VAC/180~264VAC by switch, with 254~370VDC also specified. The 12V and 15V models list 0~4.2A and 0~3.4A. Assess the selected output’s startup demand, ripple and the 20ms hold-up entry at 230VAC and full load for the actual assembly.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

S-50-24 specimen

S-50 Series Single-Output Switching Power Supply

Select one of 4 single-output versions. Compare the current and ripple at the voltage your load needs.

Select output voltage
Model
S-50-5S-50-12S-50-15S-50-24
DC output
5 V · 0–10 A12 V · 0–4.2 A15 V · 0–3.4 A24 V · 0–2.1 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
Efficiency
71%78%78%82%
Dimensions (L × W × H)
159 × 98 × 38 mm

Specifications & models

ParameterS-50-5S-50-12S-50-15S-50-24
DC output voltage and current5 V · 0–10 A12 V · 0–4.2 A15 V · 0–3.4 A24 V · 0–2.1 A
Efficiency71%78%78%82%
Ripple and noise75 mV p-p100 mV p-p100 mV p-p100 mV p-p
Line regulation±0.5%±0.5%±0.5%±0.5%
Load regulation±1%±0.5%±0.5%±0.5%
DC voltage adjustment±10%±10%±10%±10%
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush18 A at 115 V AC; 36 A at 230 V AC
Overload protection105–150%. Output shuts off; automatic recovery.
Overvoltage protection115–135%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 100 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)159 × 98 × 38 mm
Unit weight0.5 kg
Packing34 × 32 × 24 cm; 30 units/carton; 15 kg/carton
Output options
OutputCurrentEfficiencyRipple
5 V0–10 A71%75 mV p-p
12 V0–4.2 A78%100 mV p-p
15 V0–3.4 A78%100 mV p-p
24 V0–2.1 A82%100 mV p-p
Additional model specifications
S-50-5
Line regulation±0.5%
Load regulation±1%
DC voltage adjustment±10%
S-50-12
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-50-15
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-50-24
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Common specifications
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush18 A at 115 V AC; 36 A at 230 V AC
Overload protection105–150%. Output shuts off; automatic recovery.
Overvoltage protection115–135%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 100 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)159 × 98 × 38 mm
Unit weight0.5 kg
Packing34 × 32 × 24 cm; 30 units/carton; 15 kg/carton

Dimensions & technical notes

Mechanical dimensions

159 × 98 × 38 mm (L × W × H)

Wide face
S-50 wide face, dimensioned in millimetres
Narrow face
S-50 narrow face, dimensioned in millimetres

Dimensions in millimetres. The source groups the AC input pins. Check L and N on the unit; the legend does not identify them individually.

Use the printed dimensions, not the scale of the drawing, for mounting reference.

Product overview

S-50 is a single-output enclosed supply. The S-50-5 and S-50-24 are separate units, not two settings on the same unit. Select the AC band that matches the installation. The two bands are not one continuous input range.

Design features

FeatureWhat to check
Input selectionSelect the AC band that matches the installation. The two bands are not one continuous input range.
Timing at full load200 / 100 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingUse the dimensioned views for mounting. The drawing identifies a 159 × 98 mm body and a 38 mm side-view height.

Installation & applications

Installation checks

Illustrative current budget: 12 relay coils at 0.08 A each versus the 2.1 A listed limit.

Budget the relay coils together

If 12 relay coils each draw 0.08 A, their running load is 0.96 A. The S-50-24 lists 2.1 A at 24 V DC. Include the relay driver and every coil that the fixture can hold energized at once. Check peak demand and available output at the installed temperature.

S-50 body plan, 159 by 98 mm, with 38 mm table height. The adjacent load is a separate access sketch.

Allow for the body and service access

The body measures 159 × 98 × 38 mm. Leave screwdriver access with the test fixture installed, not just when the bench is empty.

Voltage check for the powered usb hub: most distant port.

Check the hub under port load

Measure at the hub input with the intended devices connected, then check the furthest device against its permitted USB voltage. Do not raise the rail to compensate for a bad lead.

Airflow check for the extraction fan: installed filter.

Test with the filter in place

Confirm fan start-up with the filter and duct fitted. Measure airflow at the inlet; an audible fan does not establish adequate extraction.

Application examples

Two plugs occupy the front of a black USB hub beside a measurement microphone and handheld recorder.

Connecting bench instruments

A powered USB hub connects bench instruments. Include devices drawing power from its ports when sizing the supply.

A white ring light surrounds a microscope objective above a polished, green-banded stone.

Inspecting a mineral specimen

An LED ring around the microscope objective lights the specimen from all sides.

A black filtered extractor faces a circuit board on a blue mat, with a soldering iron in its stand behind it.

Extracting solder fumes

A bench extractor fan draws air through a filter. Allow for the fan’s starting current.

Four clear-cased relays sit in front of an open pin fixture holding a green circuit board.

Switching measurement paths

Relay coils select measurement paths in a test fixture. Count the coils that can energize together.

Match the selected output voltage and available current to the USB hub, ring light controller, extractor fan or relay coils.

AI-generated application illustrations, not customer installation photographs.

Frequently asked questions

Which outputs can I specify for S-50?

The standard sheet lists 5 V, 12 V, 15 V, 24 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.

What space should I allow?

Use the dimensioned views for mounting. The drawing identifies a 159 × 98 mm body and a 38 mm side-view height.

What happens on overload?

105–150%. Output shuts off; automatic recovery.

S-50-24 specimen · upright, terminals at the bottom

WEHO S-50-24 power supply, upright, terminals at the bottom

S-50-24 specimen

WEHO S-50-24 power supply — upright perforated cover and nameplate side

S-50-24 specimen · terminal end, cover and side, three-quarter

WEHO S-50-24 power supply — terminal end, cover and side, three-quarter

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO S-50-24 power supply, upright, terminals at the bottom
S-50-24 specimen
Selected model
S-50-5S-50-12S-50-15S-50-24
DC output
5 V · 0–10 A12 V · 0–4.2 A15 V · 0–3.4 A24 V · 0–2.1 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.