S-120W series normal single switching power supply

WEHO S-120 provides six separate single-output alternatives from 12V to 48V in a 199×98×38mm enclosure. The 120W-designated family includes 15V and 18V versions, with output-specific stability and efficiency figures for equipment-electronics selection. AC input is 90~132VAC/180~264VAC by switch, and 254~370VDC is also listed. Evaluate one exact suffix for compatible local controller, status or communication boards. The printed current ranges do not establish a continuous-power guarantee; verify startup, cooling, load and terminal conditions in the complete equipment.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

S-120-12 specimen

S-120 Series Single-Output Switching Power Supply

Select one of 6 single-output versions. Compare the current and ripple at the voltage your load needs.

Select output voltage
Model
S-120-12S-120-15S-120-18S-120-24S-120-36S-120-48
DC output
12 V · 0–10 A15 V · 0–8 A18 V · 0–6.7 A24 V · 0–5 A36 V · 0–3.3 A48 V · 0–2.5 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
254–370 V DC
Efficiency
81%82%84%84%84%84%
Dimensions (L × W × H)
199 × 98 × 38 mm

Specifications & models

ParameterS-120-12S-120-15S-120-18S-120-24S-120-36S-120-48
DC output voltage and current12 V · 0–10 A15 V · 0–8 A18 V · 0–6.7 A24 V · 0–5 A36 V · 0–3.3 A48 V · 0–2.5 A
Efficiency81%82%84%84%84%84%
Ripple and noise100 mV p-p100 mV p-p100 mV p-p100 mV p-p100 mV p-p100 mV p-p
Line regulation±0.3%±0.3%±0.2%±0.2%±0.2%±0.2%
Load regulation±0.3%±0.3%±0.2%±0.2%±0.2%±0.2%
DC voltage adjustment±10%±10%±10%±10%±10%±10%
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush30 A at 115 V AC; 60 A at 230 V AC
Overload protection105–150%. Output shuts off; automatic recovery.
Overvoltage protection115–135%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)199 × 98 × 38 mm
Unit weight0.6 kg
Packing43 × 32.5 × 24 cm; 30 units/carton; 18 kg/carton
Output options
OutputCurrentEfficiencyRipple
12 V0–10 A81%100 mV p-p
15 V0–8 A82%100 mV p-p
18 V0–6.7 A84%100 mV p-p
24 V0–5 A84%100 mV p-p
36 V0–3.3 A84%100 mV p-p
48 V0–2.5 A84%100 mV p-p
Additional model specifications
S-120-12
Line regulation±0.3%
Load regulation±0.3%
DC voltage adjustment±10%
S-120-15
Line regulation±0.3%
Load regulation±0.3%
DC voltage adjustment±10%
S-120-18
Line regulation±0.2%
Load regulation±0.2%
DC voltage adjustment±10%
S-120-24
Line regulation±0.2%
Load regulation±0.2%
DC voltage adjustment±10%
S-120-36
Line regulation±0.2%
Load regulation±0.2%
DC voltage adjustment±10%
S-120-48
Line regulation±0.2%
Load regulation±0.2%
DC voltage adjustment±10%
Common specifications
Input voltage90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz
Cold-start inrush30 A at 115 V AC; 60 A at 230 V AC
Overload protection105–150%. Output shuts off; automatic recovery.
Overvoltage protection115–135%. Output shuts off; cycle input power to recover.
Setup / rise / hold-up200 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)199 × 98 × 38 mm
Unit weight0.6 kg
Packing43 × 32.5 × 24 cm; 30 units/carton; 18 kg/carton

Dimensions & technical notes

Mechanical dimensions

199 × 98 × 38 mm (L × W × H)

Wide face
S-120 wide face, dimensioned in millimetres
Narrow face
S-120 narrow face, dimensioned in millimetres

Dimensions in millimetres. The source groups the AC input pins. Check L and N on the unit; the legend does not identify them individually.

Use the printed dimensions, not the scale of the drawing, for mounting reference.

Product overview

S-120 is a single-output enclosed supply. The S-120-12 and S-120-48 are separate units, not two settings on the same unit. Select the AC band that matches the installation. The two bands are not one continuous input range.

Design features

FeatureWhat to check
Input selectionSelect the AC band that matches the installation. The two bands are not one continuous input range.
Timing at full load200 / 50 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingUse the dimensioned views for mounting. The drawing identifies a 199 × 98 mm body and a 38 mm side-view height.

Installation & applications

Installation checks

Illustrative current budget: 8 signal towers at 0.25 A each versus the 5 A listed limit.

Budget the signal towers together

If 8 signal towers each draw 0.25 A, their running load is 2 A. The S-120-24 lists 5 A at 24 V DC. Use the current with every allowed tier lit, not the current for a single LED tier. Check peak demand and available output at the installed temperature.

S-120 body plan, 199 by 98 mm, with 38 mm table height. The adjacent load is a separate access sketch.

Allow for the body and service access

The body measures 199 × 98 × 38 mm. Leave a path for separate signal and lamp wiring when the cable-duct cover is in place.

Interface check for the tension amplifier: bridge excitation.

Check the idler bridge supply

Verify that the load cells receive the excitation specified by the tension amplifier. Keep their measurement leads separate from the drive wiring.

Functional check for the vacuum sensor: pickup cycle.

Check suction before sheet pickup

With the feeder in its approved test mode, confirm that the vacuum input changes state at the required point in the cycle. The sensor's DC supply does not establish suction.

Application examples

Violet fabric wraps over a broad roller; a cabled shaft-end fitting connects to a small box on the frame.

Monitoring textile tension

A signal amplifier reads the force at the roller supports as fabric moves over the roller.

A white linear lamp runs beside the uneven edge of a reflective metal sheet against a black background.

Inspecting a slit foil edge

A linear lamp casts light along the foil edge so the operator can see irregularities.

A green segment glows on a stack light above a dark green press and piles of cream paper.

Showing press status

A tower light shows press status across the room. Count the segments that can light together.

Pale blue tubing links a black switch and three suction cups resting on a stack of blue paper.

Monitoring a sheet feeder

A vacuum switch monitors suction at the sheet feeder. The vacuum generator is a separate load.

Match the selected output voltage and available current to the signal amplifier, inspection lamp, tower light or vacuum switch.

AI-generated application illustrations, not customer installation photographs.

Frequently asked questions

Which outputs can I specify for S-120?

The standard sheet lists 12 V, 15 V, 18 V, 24 V, 36 V, 48 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.

What space should I allow?

Use the dimensioned views for mounting. The drawing identifies a 199 × 98 mm body and a 38 mm side-view height.

What happens on overload?

105–150%. Output shuts off; automatic recovery.

S-120-12 specimen · upright, terminals at the bottom

WEHO S-120-12 power supply, upright, terminals at the bottom

S-120-12 specimen

WEHO S-120-12 power supply — upright perforated cover and nameplate side

S-120-12 specimen · terminal end, cover and side, three-quarter

WEHO S-120-12 power supply — terminal end, cover and side, three-quarter

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO S-120-12 power supply, upright, terminals at the bottom
S-120-12 specimen
Selected model
S-120-12S-120-15S-120-18S-120-24S-120-36S-120-48
DC output
12 V · 0–10 A15 V · 0–8 A18 V · 0–6.7 A24 V · 0–5 A36 V · 0–3.3 A48 V · 0–2.5 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.