S-3000W series normal single switching power supply

WEHO S-3000 is a 3000W-class enclosed single-output family for engineered high-current DC loads, with a listed 200~264VAC input. Separate models provide 24V 0~125A, 27V 0~111A, 36V 0~83A or 48V 0~62.5A. Use it as a candidate for a defined DC equipment rail or load-test assembly, with exact-variant, wiring and thermal validation; neither the family wattage nor a current-range endpoint establishes continuous duty in every enclosure.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

S-3000-24 specimen

S-3000 Series Single-Output Switching Power Supply

Select one of 4 single-output versions. Compare the current and ripple at the voltage your load needs.

Select output voltage
Model
S-3000-24S-3000-27S-3000-36S-3000-48
DC output
24 V · 0–125 A27 V · 0–111 A36 V · 0–83 A48 V · 0–62.5 A
AC input
200–264 V AC
DC input
Not specified
Efficiency
80%82%85%87%
Dimensions (L × W × H)
291 × 132 × 136 mm (table); 132 mm high in end view. Confirm before mounting.

Specifications & models

ParameterS-3000-24S-3000-27S-3000-36S-3000-48
DC output voltage and current24 V · 0–125 A27 V · 0–111 A36 V · 0–83 A48 V · 0–62.5 A
Efficiency80%82%85%87%
Ripple and noise240 mV p-p240 mV p-p300 mV p-p300 mV p-p
Line regulation±0.5%±0.5%±0.5%±0.5%
Load regulation±0.5%±0.5%±0.5%±0.5%
DC voltage adjustment±10%±10%±10%±10%
Input voltage200-264 V AC
Cold-start inrush70 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protectionNot specified in this sheet.
Setup / rise / hold-up2000 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)291 × 132 × 136 mm (table); fan-end view: 132 mm high. Confirm clearance.
Unit weight5.3 kg
Packing38 × 37.5 × 21 cm; 2 units/carton; 11 kg/carton
Output options
OutputCurrentEfficiencyRipple
24 V0–125 A80%240 mV p-p
27 V0–111 A82%240 mV p-p
36 V0–83 A85%300 mV p-p
48 V0–62.5 A87%300 mV p-p
Additional model specifications
S-3000-24
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-3000-27
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-3000-36
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
S-3000-48
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Common specifications
Input voltage200-264 V AC
Cold-start inrush70 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protectionNot specified in this sheet.
Setup / rise / hold-up2000 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)291 × 132 × 136 mm (table); fan-end view: 132 mm high. Confirm clearance.
Unit weight5.3 kg
Packing38 × 37.5 × 21 cm; 2 units/carton; 11 kg/carton

Dimensions & technical notes

Mechanical dimensions

291 × 132 × 136 mm (table L × W × H)

Wide face
S-3000 wide face, dimensioned in millimetres
Narrow face
S-3000 narrow face, dimensioned in millimetres
Fan end
S-3000 fan end, dimensioned in millimetres
Connector end
S-3000 connector end, dimensioned in millimetres

Dimensions in millimetres. The connector view numbers three positions but gives no pin-to-function key. Confirm the connections on the unit.

The table lists 136 mm in height; the fan-end drawing shows 132 mm. Confirm installed height before setting clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

Product overview

S-3000 is a single-output enclosed supply. The S-3000-24 and S-3000-48 are separate units, not two settings on the same unit. Only the stated AC band is documented. Do not use a lower-voltage band from another model.

Design features

FeatureWhat to check
Input selectionOnly the stated AC band is documented. Do not use a lower-voltage band from another model.
Timing at full load2000 / 50 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingThe table lists a height of 136 mm; the fan-end drawing shows 132 mm. Confirm the installed height before fixing enclosure clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

Installation & applications

Installation checks

Illustrative current budget: 4 electronic load channels at 10 A each versus the 62.5 A listed limit.

Budget the electronic load channels together

If 4 electronic load channels each draw 10 A, their running load is 40 A. The S-3000-48 lists 62.5 A at 48 V DC. Check each channel's input power dissipation and the sum of the commanded currents before enabling the sink. Check peak demand and available output at the installed temperature.

S-3000 body plan, 291 by 132 mm, with 136 mm table height; the end view shows 132 mm vertically. The adjacent load is a separate access sketch.

Confirm the installed height

The table gives 291 × 132 × 136 mm, but the end view marks 132 mm vertically. Confirm the installed height before laying out the enclosure. Allow for guarded bus distribution, tool access and the actual lug and cable bend beyond the case.

Voltage check for the sign-cabinet inputs: last cabinet input.

Check the loaded sign wall

Select full brightness on all test cabinets. Measure at the most distant cabinet and compare with its allowed input before attributing dimming to the LED modules.

Airflow check for the ec fan test stands: guarded fan stand.

Test with fan guards fitted

Verify the commanded fan speed with the final guard in place and measure the stand's airflow. Keep the tachometer and cables outside the guarded rotating area.

Application examples

Four programmable load instruments connect by heavy test leads to a distribution rack.

Loading a DC distribution rack

Electronic loads draw from the 48 V source. Keep their combined setting within verified supply limits and each load’s dissipation rating.

A frame holds four illuminated sign cabinets with different shapes and coloured symbols.

Powering fixtures on an outdoor-sign test wall

The test wall feeds dedicated 24 V sign inputs. Protect each branch and check combined full-brightness demand; provide weather protection separately.

Strapped flexible heater blankets follow the inside curve of a mould held in a tooling cradle.

Heating a curved mould in sections

Independently controlled 36 V blankets heat the curved mould. Check fit, attachment, power density and overtemperature limits for each zone.

A row of guarded axial fans stands in individual floor-mounted production test frames.

Testing air movers in production batches

The 48 V rail feeds rated EC fans on test frames. Check simultaneous start current, harness limits and fan protection; speed commands come from the controller.

Match the selected S-3000 output voltage and available current to each load.

AI-generated application illustrations, not customer installation photographs.

Frequently asked questions

Which outputs can I specify for S-3000?

The standard sheet lists 24 V, 27 V, 36 V, 48 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

200-264 V AC. Only the stated AC band is documented. Do not use a lower-voltage band from another model.

What space should I allow?

The table lists a height of 136 mm; the fan-end drawing shows 132 mm. Confirm the installed height before fixing enclosure clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

What happens on overload?

105–135%. Output shuts off; automatic recovery.

S-3000-24 specimen · upright tower, terminals at the top

WEHO S-3000-24 power supply, upright tower, terminals at the top

S-3000-24 specimen

WEHO S-3000-24 power supply — fan, output connections and nameplate detail

S-3000-24 specimen · fan/output end and cover, three-quarter

WEHO S-3000-24 power supply — fan/output end and cover, three-quarter

S-3000-24 specimen · fan, output connections and nameplate detail

WEHO S-3000-24 power supply — fan, output connections and nameplate detail

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO S-3000-24 power supply, upright tower, terminals at the top
S-3000-24 specimen
Selected model
S-3000-24S-3000-27S-3000-36S-3000-48
DC output
24 V · 0–125 A27 V · 0–111 A36 V · 0–83 A48 V · 0–62.5 A

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.