LRS-200 200W PSU, Switch-Selectable AC Input

The LRS-200 is a 200W-class single-output enclosed power supply with a 30mm-high body. Select 90–132VAC or 180–264VAC using the input-range switch; the DC input range is 240–370VDC and the AC frequency range is 47–63Hz. Output versions are 12V, 15V, 24V and 48V. Match the exact model suffix and listed current range to the load.
LRS-200 series serves as a high-price-to-performance power supply solution for various industrial applications.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

LRS-200 representative shown

LRS-200 Enclosed Switching Power Supply

Single-output AC–DC supply with switch-selectable AC input.

Output voltage
Model
LRS-200-5LRS-200-12LRS-200-15LRS-200-24LRS-200-48
DC output
5 V · 0–40 A12 V · 0–17 A15 V · 0–14 A24 V · 0–8.8 A48 V · 0–4.4 A
AC input
90–132 V AC / 180–264 V AC (by switch)
DC input
240–370 V DC
Efficiency
85.5%85.5%86%88%89%
Dimensions (L × W × H)
215 × 115 × 30 mm

Specifications & models

ParameterLRS-200-5LRS-200-12LRS-200-15LRS-200-24LRS-200-48
DC output voltage and current5 V · 0–40 A12V 0~17A15V0~14A24V0~8.8A48V 0~4.4A
Input voltage range90–132VAC / 180–264VAC by switch; 240–370VDC; 47–63Hz
Dimensions215×115×30mm
Efficiency85.5%85.5%86%88%89%
Working temperature-20℃~+70℃
Ripple & noise150mVp-P150mVp-P150mVp-P150mVp-P200mVp-P
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Inrush currentCold start current 60A/230VAC
Overload protection110%~150%cut off the output,automatic recovery
Other protectionOvercurrent protection /Short-circuit protection
Timing (setup / rise / hold-up)1500ms,50ms/230VAC 1500ms,50ms/115VAC. No separate hold-up time is specified.
Withstand voltageI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute
Insulation resistanceI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
Weight0.66kg
Packing37.5×25×26CM/20PCS/13kg
Output options
OutputCurrentEfficiencyRipple (mVp-p)
5 V0–40 A85.5%150
12 V0–17 A85.5%150
15 V0–14 A86%150
24 V0–8.8 A88%150
48 V0–4.4 A89%200
Specifications for 5 V, 12 V, 15 V, 24 V, 48 V
Input voltage range90–132VAC / 180–264VAC by switch; 240–370VDC; 47–63Hz
Dimensions215×115×30mm
Working temperature-20℃~+70℃
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Inrush currentCold start current 60A/230VAC
Overload protection110%~150%cut off the output,automatic recovery
Other protectionOvercurrent protection /Short-circuit protection
Timing (setup / rise / hold-up)1500ms,50ms/230VAC 1500ms,50ms/115VAC. No separate hold-up time is specified.
Withstand voltageI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute
Insulation resistanceI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH
Weight0.66kg
Packing37.5×25×26CM/20PCS/13kg

Dimensions & derating

Mechanical dimensions

215 × 115 × 30 mm (L × W × H)

Wide face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
Narrow face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Body width: 115 mm. Width including mounting ears: 135 mm. Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face. Body dimensions and mounting-hole spacing are separate references.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Product overview

For a 24 V control rail, the LRS-200-24 has a listed output range of 0–8.8 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. For equipment shipped into different AC markets, specify the correct selector position during commissioning. The 90–132 V and 180–264 V bands are distinct; an input between them is not covered.

Design features

FeatureWhat to check
Output trimUse the listed ±10% adjustment only within the load’s input limits.
Enclosure fitConfirm the mounting dimensions and allow room for wiring bends, airflow and terminal access.
Overload recoveryThe output recovers after the overload condition is removed. Check how the equipment restarts.

Installation & applications

Installation checks

A closed instrument, a clipboard and a handheld meter on a workshop bench.

Match the supply to the load

Check the incoming supply against 90–132 V AC / 180–264 V AC (by switch). Add the starting currents of devices that energize together before selecting the output version.

A closed, vented equipment cabinet beside a clear service aisle and a wall grille.

Leave room for service

Confirm the body, mounting-hole positions and terminal access against the drawing before laying out the panel.

An environmental test chamber with a lit observation window and an instrument cart.

Check the installed temperature

The listed working range is -20 to +70 °C. Measure the air near the installed supply under sustained load. Use the applicable loading curve within its stated limits.

An empty roller conveyor behind a yellow barrier, with a closed equipment cabinet beside it.

Plan for power returning

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

A freestanding illuminated lightbox outside a glass-fronted shop at dusk.

Retail signage

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.

24 V option: LRS-200-24 · listed current 0–8.8 A.

Indoor parcel lockers with a touchscreen and a parcel in an open compartment.

Parcel lockers

Size the rail for sensors and the operator interface. Account separately for lock pickup current.

12 V option: LRS-200-12 · listed current 0–17 A.

A carton passes a bracket-mounted photoelectric sensor with an amber status light on a conveyor belt.

Carton packaging

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.

24 V option: LRS-200-24 · listed current 0–8.8 A.

A circuit board clamped below an inspection camera, with an enlarged board view on a monitor.

Electronics test fixtures

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.

12 V option: LRS-200-12 · listed current 0–17 A.

AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.

Frequently asked questions

Which output voltages are available?

Choose one nominal output: 5 V, 12 V, 15 V, 24 V, 48 V. Each voltage is a separate model.

Which input voltage should I specify?

The listed AC input is 90–132 V AC / 180–264 V AC (by switch); the DC input is 240–370 V DC. The gap between the two AC bands is not part of the specified input range.

How much current is listed for the 24 V model?

LRS-200-24 is listed at 0–8.8 A. Check the current at startup as well as in steady operation.

What does the series power designation mean?

The datasheet gives output current by voltage. Use the selected model’s current range and application conditions rather than treating the series name as a continuous rating for every version.

What temperature range can I use?

The working range is -20 to +70 °C. Check the applicable input and mounting conditions on the loading curves.

How do I check the mounting space?

The listed body measures 215 × 115 × 30 mm. Check the drawing for mounting dimensions and allow additional room for wiring and airflow.

What inrush current is listed?

The cold-start input current is 60 A at 230 V AC. This is an input-side event, not the current available to the DC load.

What should I include in my quote request?

Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.

In the inquiry form, enter model LRS-200-5LRS-200-12LRS-200-15LRS-200-24LRS-200-48 with your requirements.

LRS-200 datasheet

Close
Download PDF
LRS-200 datasheet, page 1 of 2: Electrical specifications.
LRS-200 datasheet, page 2 of 2: Mechanical drawing and performance curves.

LRS-200 product photograph

LRS-200 representative product photograph

Wide face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Narrow face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.