LRS-100 Series 100W Single Output Enclosed Switching Power Supply (LRS-100-12 / LRS-100-24)

Single-Output Versions: LRS-100-12, LRS-100-15, LRS-100-24 and LRS-100-48 provide 12V, 15V, 24V and 48V. Listed current ranges are 0~8.5A, 0~7A, 0~4.5A and 0~2.3A respectively.

Efficiency by Version: 86%, 88%, 88% and 90% in the same voltage order.

Input and Size: 85~264VAC or 120~373VDC, 47~63Hz; 129×97×30mm enclosure.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

LRS-100 representative shown

LRS-100 Enclosed Switching Power Supply

Single-output AC–DC supply for 85–264 V AC input.

Output voltage
Model
LRS-100-5LRS-100-12LRS-100-15LRS-100-24LRS-100-48
DC output
5 V · 0–20 A12 V · 0–8.5 A15 V · 0–7 A24 V · 0–4.5 A48 V · 0–2.3 A
AC input
85–264 V AC
DC input
120–373 V DC
Efficiency
86%86%88%88%90%
Dimensions (L × W × H)
129 × 97 × 30 mm

Specifications & models

ParameterLRS-100-5LRS-100-12LRS-100-15LRS-100-24LRS-100-48
DC output voltage and current5 V · 0–20 A12V 0~8.5A15V 0~7A24V 0~4.5A48V 0~2.3A
Input voltage range85~264VAC / 120~373VDC, 47~63Hz
Dimensions129×97×30mm
Efficiency86%86%88%88%90%
Working temperature-20℃~+70℃
Ripple & noise120mVp-p120mVp-p120mVp-p150mVp-p200mVp-p
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Inrush currentCold start current 50A/230VAC
Overload protection110%~150%cut off the output,automatic recovery
Other protectionOvercurrent protection /Short-circuit protection
Timing (setup / rise / hold-up)230VAC: 500ms, 30ms; 115VAC: 500ms, 30ms. No separate hold-up time is specified.
Withstand voltageI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute
Insulation resistanceI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃ /70%RH
Weight0.34kg
Packing42.5×32.5×19.5CM/45PCS/16kg
Output options
OutputCurrentEfficiencyRipple (mVp-p)
5 V0–20 A86%120
12 V0–8.5 A86%120
15 V0–7 A88%120
24 V0–4.5 A88%150
48 V0–2.3 A90%200
Specifications for 5 V, 12 V, 15 V, 24 V, 48 V
Input voltage range85~264VAC / 120~373VDC, 47~63Hz
Dimensions129×97×30mm
Working temperature-20℃~+70℃
Line regulation±0.5%
Load regulation±0.5%
DC voltage adjustment±10%
Inrush currentCold start current 50A/230VAC
Overload protection110%~150%cut off the output,automatic recovery
Other protectionOvercurrent protection /Short-circuit protection
Timing (setup / rise / hold-up)230VAC: 500ms, 30ms; 115VAC: 500ms, 30ms. No separate hold-up time is specified.
Withstand voltageI/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute
Insulation resistanceI/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃ /70%RH
Weight0.34kg
Packing42.5×32.5×19.5CM/45PCS/16kg

Dimensions & derating

Mechanical dimensions

129 × 97 × 30 mm (L × W × H)

Wide face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.
Narrow face
WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face. Body dimensions and mounting-hole spacing are separate references.

Load derating

Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. A reference axis extending below that range does not extend the product rating. Follow the input-voltage and mounting-orientation labels shown on each curve.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.
Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.
Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.
View the functional block diagram Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Product overview

For a 24 V control rail, the LRS-100-24 has a listed output range of 0–4.5 A. Compare that range with the combined demand of your controllers, sensors and interface modules, including devices that start together. For a test fixture, check both ripple tolerance and the interval between AC energization and DC output. The setup and rise figures are not a promise that the load will ride through a mains interruption.

Design features

FeatureWhat to check
Output trimUse the listed ±10% adjustment only within the load’s input limits.
Enclosure fitConfirm the mounting dimensions and allow room for wiring bends, airflow and terminal access.
Overload recoveryThe output recovers after the overload condition is removed. Check how the equipment restarts.

Installation & applications

Installation checks

A closed instrument, a clipboard and a handheld meter on a workshop bench.

Match the supply to the load

Check the incoming supply against 85–264 V AC. Add the starting currents of devices that energize together before selecting the output version.

A closed, vented equipment cabinet beside a clear service aisle and a wall grille.

Leave room for service

Confirm the body, mounting-hole positions and terminal access against the drawing before laying out the panel.

An environmental test chamber with a lit observation window and an instrument cart.

Check the installed temperature

The listed working range is -20 to +70 °C. Measure the air near the installed supply under sustained load. Use the applicable loading curve within its stated limits.

An empty roller conveyor behind a yellow barrier, with a closed equipment cabinet beside it.

Plan for power returning

When power returns, the controls may restart before the machine is ready. Check the host equipment’s restart sequence independently.

Application examples

Size the supply for the auxiliary electronics, not for the whole machine.

A freestanding illuminated lightbox outside a glass-fronted shop at dusk.

Retail signage

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.

24 V option: LRS-100-24 · listed current 0–4.5 A.

Indoor parcel lockers with a touchscreen and a parcel in an open compartment.

Parcel lockers

Size the rail for sensors and the operator interface. Account separately for lock pickup current.

12 V option: LRS-100-12 · listed current 0–8.5 A.

A carton passes a bracket-mounted photoelectric sensor with an amber status light on a conveyor belt.

Carton packaging

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.

24 V option: LRS-100-24 · listed current 0–4.5 A.

A circuit board clamped below an inspection camera, with an enlarged board view on a monitor.

Electronics test fixtures

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.

12 V option: LRS-100-12 · listed current 0–8.5 A.

AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.

Frequently asked questions

Which output voltages are available?

Choose one nominal output: 5 V, 12 V, 15 V, 24 V, 48 V. Each voltage is a separate model.

Which input voltage should I specify?

The listed AC input is 85–264 V AC; the DC input is 120–373 V DC. The sheet gives a continuous AC range but does not specify the range-selection method.

How much current is listed for the 24 V model?

LRS-100-24 is listed at 0–4.5 A. Check the current at startup as well as in steady operation.

What does the series power designation mean?

The datasheet gives output current by voltage. Use the selected model’s current range and application conditions rather than treating the series name as a continuous rating for every version.

What temperature range can I use?

The working range is -20 to +70 °C. Check the applicable input and mounting conditions on the loading curves.

How do I check the mounting space?

The listed body measures 129 × 97 × 30 mm. Check the drawing for mounting dimensions and allow additional room for wiring and airflow.

What inrush current is listed?

The cold-start input current is 50 A at 230 V AC. This is an input-side event, not the current available to the DC load.

What should I include in my quote request?

Include the exact model, quantity, input source, load profile and destination. Include the available mounting space if the enclosure is tight.

In the inquiry form, enter model LRS-100-5LRS-100-12LRS-100-15LRS-100-24LRS-100-48 with your requirements.

LRS-100 datasheet

Close
Download PDF
LRS-100 datasheet, page 1 of 2: Electrical specifications.
LRS-100 datasheet, page 2 of 2: Mechanical drawing and performance curves.

LRS-100 product photograph

LRS-100 representative product photograph

Wide face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Narrow face

WEHO dimensioned outline and mounting details, in millimetres. Read the printed callouts.

Permitted load versus ambient temperature. Observe the separate input-voltage curves where shown.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

Permitted load versus AC input voltage at the frequency shown. Use the correct input selector setting where applicable.

Native technical vectors from the owner-adopted same-model reference. All source input, output and installation conditions remain applicable; do not extrapolate beyond the WEHO stated limits.

What’s the best Power Supply products for your business?

Boost your business with WEHO quality power supply prooducts.

Ask an Expert
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.