Size the DC output for the load
Add the running currents of all devices on the same output. Check their combined start-up demand as well: the S-15-24 supplies up to 0.7 A at 24 V DC.
WEHO S-15 is a 15W-designated single-output power-supply family for compatible local control, display and interface electronics. Separate 5V, 12V, 15V and 24V versions use a 98×97×35mm enclosure and have a listed mass of 0.3kg. AC input is 90~132VAC/180~264VAC by switch; 254~370VDC is also listed. Choose the exact output suffix and confirm load, startup, thermal and connection requirements for the equipment.
If you have any questions, please do not hesitate to contact us at Email: [email protected]
Select one of 4 single-output versions. Compare the current and ripple at the voltage your load needs.
| Parameter | S-15-5 | S-15-12 | S-15-15 | S-15-24 |
|---|---|---|---|---|
| DC output voltage and current | 5 V · 0–3 A | 12 V · 0–1.3 A | 15 V · 0–1 A | 24 V · 0–0.7 A |
| Efficiency | 65% | 68% | 70% | 72% |
| Ripple and noise | 50 mV p-p | 50 mV p-p | 75 mV p-p | 100 mV p-p |
| Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load regulation | ±1% | ±0.5% | ±0.5% | ±0.5% |
| DC voltage adjustment | ±10% | ±10% | ±10% | ±10% |
| Input voltage | 90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz | |||
| Cold-start inrush | 15 A at 115 V AC; 30 A at 230 V AC | |||
| Overload protection | 105–150%. Output shuts off; automatic recovery. | |||
| Overvoltage protection | 115–135%. Output shuts off; cycle input power to recover. | |||
| Setup / rise / hold-up | 200 / 100 / 30 ms at 230 V AC, full load | |||
| Withstand voltage | Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min) | |||
| Insulation resistance | 100 MΩ at 500 V DC: input-output, input-FG, output-FG | |||
| Operating temperature | -10 to 50 °C | |||
| Dimensions (L × W × H) | 98 × 97 × 35 mm | |||
| Unit weight | 0.3 kg | |||
| Packing | 43 × 32.5 × 24 cm; 60 units/carton; 18 kg/carton | |||
| Output | Current | Efficiency | Ripple |
|---|---|---|---|
| 5 V | 0–3 A | 65% | 50 mV p-p |
| 12 V | 0–1.3 A | 68% | 50 mV p-p |
| 15 V | 0–1 A | 70% | 75 mV p-p |
| 24 V | 0–0.7 A | 72% | 100 mV p-p |
| Line regulation | ±0.5% |
|---|---|
| Load regulation | ±1% |
| DC voltage adjustment | ±10% |
| Line regulation | ±0.5% |
|---|---|
| Load regulation | ±0.5% |
| DC voltage adjustment | ±10% |
| Line regulation | ±0.5% |
|---|---|
| Load regulation | ±0.5% |
| DC voltage adjustment | ±10% |
| Line regulation | ±0.5% |
|---|---|
| Load regulation | ±0.5% |
| DC voltage adjustment | ±10% |
| Input voltage | 90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz |
|---|---|
| Cold-start inrush | 15 A at 115 V AC; 30 A at 230 V AC |
| Overload protection | 105–150%. Output shuts off; automatic recovery. |
| Overvoltage protection | 115–135%. Output shuts off; cycle input power to recover. |
| Setup / rise / hold-up | 200 / 100 / 30 ms at 230 V AC, full load |
| Withstand voltage | Input–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min) |
| Insulation resistance | 100 MΩ at 500 V DC: input-output, input-FG, output-FG |
| Operating temperature | -10 to 50 °C |
| Dimensions (L × W × H) | 98 × 97 × 35 mm |
| Unit weight | 0.3 kg |
| Packing | 43 × 32.5 × 24 cm; 60 units/carton; 18 kg/carton |
98 × 97 × 35 mm (L × W × H)
Dimensions in millimetres. Pin numbers refer to the wide face. The drawing groups pins 4 and 5 as AC input; check L and N on the unit.
| Feature | What to check |
|---|---|
| Input selection | Select the AC band that matches the installation. The two bands are not one continuous input range. |
| Timing at full load | 200 / 100 / 30 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range. |
| Case and mounting | Use the dimensioned views for mounting. The drawing identifies a 98 × 97 mm body and a 35 mm side-view height. |

Add the running currents of all devices on the same output. Check their combined start-up demand as well: the S-15-24 supplies up to 0.7 A at 24 V DC.

The case measures 98 × 97 × 35 mm. Allow extra space beyond the case for cable bends and access to the terminal screws. Use the dimensioned drawing to locate the mounting holes.

Keep the perforated cover clear. Check the air temperature next to the supply with the enclosure closed and the intended loads running.

When power returns, check that the sensor, reader or indicator starts as intended. The S-15 powers the DC load; machine restart and safety functions belong to the machine controller.

A photoelectric sensor detects each bottle as it passes the guide rail.

A green pilot light shows the operator the status of the assembly station.

A short LED bar lights the movement on the watchmaker’s bench.

A fixed reader scans a parts bin as it arrives at the receiving station.
Match the selected output voltage and current to the sensor, indicator, light or reader.
AI-generated application illustrations, not customer installation photographs.
The standard sheet lists 5 V, 12 V, 15 V, 24 V. Order the full suffix for the required output; the selector compares different units.
90-132 V AC or 180-264 V AC (by switch); 254-370 V DC; 47-63 Hz. Select the AC band that matches the installation. The two bands are not one continuous input range.
Use the dimensioned views for mounting. The drawing identifies a 98 × 97 mm body and a 35 mm side-view height.
105–150%. Output shuts off; automatic recovery.
An interactive S-15 preview and a STEP download are not available yet. For mounting dimensions, see the dimensioned drawing on this page.




Tell us how many units you need and where they will be delivered.

Boost your business with WEHO quality power supply prooducts.
Ask an Expert