S-2400W series normal single switching power supply

WEHO S-2400 is a 2400W-class enclosed single-output power-supply family with a listed 200~264VAC input. Its four output choices are 24V 0~100A, 27V 0~89A, 36V 0~67A and 48V 0~50A. It is a candidate for substantial DC assembly-test and loading equipment when the exact voltage, wiring and operating duty are validated together; the power-class label and printed current ranges are not an unconditional continuous-duty guarantee.

If you have any questions, please do not hesitate to contact us at Email: [email protected]

S-2400-24 specimen

S-2400 Series Single-Output Switching Power Supply

Select one of 4 single-output versions. Compare the current and ripple at the voltage your load needs.

Select output voltage
Model
S-2400-24S-2400-27S-2400-36S-2400-48
DC output
24 V · 0–100 A27 V · 0–89 A36 V · 0–67 A48 V · 0–50 A
AC input
200–264 V AC
DC input
Not specified
Efficiency
80%85%86%87%
Dimensions (L × W × H)
291 × 132 × 136 mm (table); 132 mm high in end view. Confirm before mounting.

Specifications & models

ParameterS-2400-24S-2400-27S-2400-36S-2400-48
DC output voltage and current24 V · 0–100 A27 V · 0–89 A36 V · 0–67 A48 V · 0–50 A
Efficiency80%85%86%87%
Ripple and noise120 mV p-p200 mV p-p200 mV p-p240 mV p-p
Line regulation+0.5%+0.5%+0.5%+0.5%
Load regulation+0.5%+0.5%+0.5%+0.5%
DC voltage adjustment10%; sign unconfirmed10%; sign unconfirmed10%; sign unconfirmed10%; sign unconfirmed
Input voltage200-264 V AC
Cold-start inrush45 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protectionNot specified in this sheet.
Setup / rise / hold-up2000 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)291 × 132 × 136 mm (table); fan-end view: 132 mm high. Confirm clearance.
Unit weight5.3 kg
Packing38 × 37.5 × 21 cm; 2 units/carton; 11 kg/carton
Output options
OutputCurrentEfficiencyRipple
24 V0–100 A80%120 mV p-p
27 V0–89 A85%200 mV p-p
36 V0–67 A86%200 mV p-p
48 V0–50 A87%240 mV p-p
Additional model specifications
S-2400-24
Line regulation+0.5%
Load regulation+0.5%
DC voltage adjustment10%; sign unconfirmed
S-2400-27
Line regulation+0.5%
Load regulation+0.5%
DC voltage adjustment10%; sign unconfirmed
S-2400-36
Line regulation+0.5%
Load regulation+0.5%
DC voltage adjustment10%; sign unconfirmed
S-2400-48
Line regulation+0.5%
Load regulation+0.5%
DC voltage adjustment10%; sign unconfirmed
Common specifications
Input voltage200-264 V AC
Cold-start inrush45 A at 230 V AC
Overload protection105–135%. Output shuts off; automatic recovery.
Overvoltage protectionNot specified in this sheet.
Setup / rise / hold-up2000 / 50 / 20 ms at 230 V AC, full load
Withstand voltageInput–output: 1.5 kV; Input–FG: 1.5 kV; output–FG: 0.5 kV (1 min)
Insulation resistance100 MΩ at 500 V DC: input-output, input-FG, output-FG
Operating temperature-10 to 50 °C
Dimensions (L × W × H)291 × 132 × 136 mm (table); fan-end view: 132 mm high. Confirm clearance.
Unit weight5.3 kg
Packing38 × 37.5 × 21 cm; 2 units/carton; 11 kg/carton

Dimensions & technical notes

Mechanical dimensions

291 × 132 × 136 mm (table L × W × H)

Wide face
S-2400 wide face, dimensioned in millimetres
Narrow face
S-2400 narrow face, dimensioned in millimetres
Fan end
S-2400 fan end, dimensioned in millimetres
Connector end
S-2400 connector end, dimensioned in millimetres

Dimensions in millimetres. The connector view numbers three positions but gives no pin-to-function key. Confirm the connections on the unit.

The table lists 136 mm in height; the fan-end drawing shows 132 mm. Confirm installed height before setting clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

Product overview

S-2400 is a single-output enclosed supply. The S-2400-24 and S-2400-48 are separate units, not two settings on the same unit. Only the stated AC band is documented. Do not use a lower-voltage band from another model.

Design features

FeatureWhat to check
Input selectionOnly the stated AC band is documented. Do not use a lower-voltage band from another model.
Timing at full load2000 / 50 / 20 ms at 230 V AC, full load. Do not apply this test condition to an entire operating range.
Case and mountingThe table lists a height of 136 mm; the fan-end drawing shows 132 mm. Confirm the installed height before fixing enclosure clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

Installation & applications

Installation checks

Illustrative current budget: 8 platen zones at 7.5 A each versus the 100 A listed limit.

Budget the platen zones together

If 8 platen zones each draw 7.5 A, their running load is 60 A. The S-2400-24 lists 100 A at 24 V DC. Use the minimum cold resistance from the heater maker and check every branch that can energize during warm-up. Check peak demand and available output at the installed temperature.

S-2400 body plan, 291 by 132 mm, with 136 mm table height; the end view shows 132 mm vertically. The adjacent load is a separate access sketch.

Confirm the installed height

The table gives 291 × 132 × 136 mm, but the end view marks 132 mm vertically. Confirm the installed height before laying out the enclosure. Leave space for the zone distribution hardware and a protected bend in each heavy output lead.

Thermal check for the heated hose sections: curved hose section.

Check hose temperature around bends

Use the maker's permitted bend radius and sensor positions. Check temperature at bends and couplings during a controlled warm-up; a single reading at the feed end is not sufficient.

Capture a cycle for the rail-mount converter bank: primary-side input.

Measure converter-bank inrush

Capture the current on the 48 V input while enabling the populated rail. Compare it with the sum under steady secondary load and verify each branch's protection.

Application examples

Four serpentine heater zones span a long metal platen on an insulated stand.

Warming a long platen in zones

Separately switched 24 V heater zones warm the platen. Allow for all zones starting cold, DC-rated switches and external temperature limits.

A cutaway in a sleeved dispensing hose reveals the braid and heater winding near a sealant head.

Warming a sealant hose

Integral 36 V DC heaters warm the sealant hose. Check cold demand and connector ratings for its length; use separate sensing and temperature control.

A row of rail-mounted converter modules faces a second row of finned loads on a test frame.

Soak-testing field power converters

The rack feeds converters rated for 48 V input. Sum input currents under secondary load and allow for simultaneous inrush; keep outputs separate.

Hooded amber signal-lamp heads glow on separate factory test brackets.

Soak-testing signal lamp heads

The rack tests 24 V DC signal lamps, not a traffic controller. Count peak input for every lit head and its dimming interface.

Match the selected S-2400 output voltage and available current to each load.

AI-generated application illustrations, not customer installation photographs.

Frequently asked questions

Which outputs can I specify for S-2400?

The standard sheet lists 24 V, 27 V, 36 V, 48 V. Order the full suffix for the required output; the selector compares different units.

Which input can I connect?

200-264 V AC. Only the stated AC band is documented. Do not use a lower-voltage band from another model.

What space should I allow?

The table lists a height of 136 mm; the fan-end drawing shows 132 mm. Confirm the installed height before fixing enclosure clearance. Allow separately for the 30 mm terminal projection beyond the 291 mm body.

What happens on overload?

105–135%. Output shuts off; automatic recovery.

Is the output adjustment ±10%?

The adjustment figure is 10%, but its sign is unconfirmed. The separate line and load regulation entries read +0.5%.

S-2400-24 specimen · upright tower, terminals at the top

WEHO S-2400-24 power supply, upright tower, terminals at the top

S-2400-24 specimen

WEHO S-2400-24 power supply — fan, output connections and nameplate detail

S-2400-24 specimen · fan/output end and cover, three-quarter

WEHO S-2400-24 power supply — fan/output end and cover, three-quarter

S-2400-24 specimen · fan, output connections and nameplate detail

WEHO S-2400-24 power supply — fan, output connections and nameplate detail

Send Inquiry

Tell us how many units you need and where they will be delivered.

WEHO S-2400-24 power supply, upright tower, terminals at the top
S-2400-24 specimen
Selected model
S-2400-24S-2400-27S-2400-36S-2400-48
DC output
24 V · 0–100 A27 V · 0–89 A36 V · 0–67 A48 V · 0–50 A