Match the supply to the load
Check the incoming AC or DC supply. Choose the output voltage your devices require and include the current they draw when starting together.
LRS-35 is a 35W-class single-output enclosed power-supply family with a 99×82×30mm enclosure. The 12V, 15V, 24V and 48V versions list output-current ranges of 0~3A, 0~2.4A, 0~1.5A and 0~0.8A respectively.
Input: 85~264VAC or 120~373VDC, 47~63Hz. Listed efficiencies are 86%, 88%, 88% and 90% in the same voltage order. Working temperature is -20℃ to +70℃.
If you have any questions, please do not hesitate to contact us at Email: [email protected]
Single-output AC–DC power supply with a 30 mm enclosure height.
| Parameter | LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-48 |
|---|---|---|---|---|---|
| DC output voltage and current | 5V 0~7A | 12V 0~3A | 15V 0~2.4A | 24V 0~1.5A | 48V 0~0.8A |
| Input voltage range | 85~264VAC / 120~373VDC, 47~63Hz | ||||
| Dimensions | 99×82×30mm | ||||
| Efficiency | 86% | 86% | 88% | 88% | 90% |
| Working temperature | -20℃~+70℃ | ||||
| Ripple & noise | 120mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
| Line regulation | ±0.5% | ||||
| Load regulation | ±0.5% | ||||
| Output voltage adjustment | ±10% | ||||
| Inrush current | Cold start current 45A/230VAC | ||||
| Overload protection | 110%~150%cut off the output,automatic recovery | ||||
| Other protection | Overcurrent protection /Short-circuit protection | ||||
| Timing (setup / rise / hold-up) | 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified. | ||||
| Withstand voltage | I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute | ||||
| Insulation resistance | I/P-O/P I/P-FG O/P-FG:100MOhms/500VDC/25℃/70%RH | ||||
| Weight | 0.23kg | ||||
| Packing | 44×36.5×19.5CM/80PCS/16kg | ||||
| Output | Current | Efficiency | Ripple (mVp-p) |
|---|---|---|---|
| 5 V | 0–7 A | 86% | 120 |
| 12 V | 0–3 A | 86% | 120 |
| 15 V | 0–2.4 A | 88% | 120 |
| 24 V | 0–1.5 A | 88% | 150 |
| 48 V | 0–0.8 A | 90% | 200 |
| Input voltage range | 85~264VAC / 120~373VDC, 47~63Hz |
|---|---|
| Dimensions | 99×82×30mm |
| Working temperature | -20℃~+70℃ |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Output voltage adjustment | ±10% |
| Inrush current | Cold start current 45A/230VAC |
| Overload protection | 110%~150%cut off the output,automatic recovery |
| Other protection | Overcurrent protection /Short-circuit protection |
| Timing (setup / rise / hold-up) | 230VAC: 1000ms, 30ms; 115VAC: 2000ms, 30ms. No separate hold-up time is specified. |
| Withstand voltage | I/P-O/P:1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute |
| Insulation resistance | I/P-O/P I/P-FG O/P-FG:100MOhms/500VDC/25℃/70%RH |
| Weight | 0.23kg |
| Packing | 44×36.5×19.5CM/80PCS/16kg |
99 × 82 × 30 mm (L × W × H)
Dimensions in millimetres. Pin numbers correspond to the terminal strip on the wide face.
Apply these model-specific curves only within the stated WEHO operating range of -20 to +70 °C and the input range in the specification table. An axis that extends beyond the specified range does not extend the rating. Use the curve for the applicable output voltage and observe its input and mounting conditions.
The LRS-35 supplies one DC rail for controls, sensors or indicators. Its low-profile metal enclosure fits inside the host equipment. Choose the model that matches your load voltage, then check current demand and available cooling.
| Feature | What to check |
|---|---|
| Output trim | Use the ±10% adjustment to fine-tune the rail within the load’s voltage limits. |
| Low-profile case | Allow space beyond the housing for airflow, wiring bends and access to the terminals. |
| Overload recovery | The output cuts off during overload and recovers automatically. Check how the equipment restarts. |

Check the incoming AC or DC supply. Choose the output voltage your devices require and include the current they draw when starting together.

Check more than the case dimensions. Allow room for wiring bends, terminal access and airflow.

Measure near the supply during the longest duty cycle. Use the derating curves to check the load at that temperature.

The output can recover after an overload. Check the equipment’s restart behaviour and keep safety functions independent.
Size the supply for the auxiliary electronics, not for the whole machine.

Power a sign timer or a compatible display controller. LED modules may need separate current regulation.
Example: LRS-35-24 · 24 V, 0–1.5 A

Size the rail for sensors and the operator interface. Account separately for lock pickup current.
Example: LRS-35-12 · 12 V, 0–3 A

Supply sensors and indicators at the forming station. Size drive and safety circuits separately.
Example: LRS-35-15 · 15 V, 0–2.4 A

Supply status indicators or trigger interfaces. Use a separate precision source when the test requires controlled excitation.
Example: LRS-35-24 · 24 V, 0–1.5 A
AI illustrations for application planning; not installation photographs, wiring diagrams or mechanical references.
No. Each LRS-35 model provides a single nominal DC output (5 V, 12 V, 15 V, 24 V, or 48 V). If your equipment requires two independent rails, use a separate supply for each voltage or a multi-output series.
LRS-35 accepts 85–264 V AC (47–63 Hz) or 120–373 V DC. This universal input range supports both 115 V AC and 230 V AC mains without needing a manual voltage selector switch.
Yes. Each version supports ±10% output voltage adjustment via the onboard potentiometer (V.ADJ) beside the terminal block, allowing you to compensate for cable drop or match specific load requirements.
Not necessarily. Although the listed working temperature range is -20 °C to +70 °C, output current must be derated at higher ambient temperatures and lower input voltages. Always check the temperature and input-voltage derating curves above.
35 W is the series class designation. Always size your load against the exact model's current range (5 V at 0–7 A, 12 V at 0–3 A, 15 V at 0–2.4 A, 24 V at 0–1.5 A, or 48 V at 0–0.8 A) and leave margin for ambient temperature and startup surges.
LRS-35 includes overload protection (110%–150% rated output, output cutoff with automatic recovery), overcurrent protection, and short-circuit protection. Once the fault is cleared, output recovers automatically.
The enclosed metal chassis measures 99 × 82 × 30 mm (0.23 kg) and cools by free-air convection. Check the mechanical drawing for M3 mounting hole locations and leave clearance around the perforated cover and terminal block for wiring and airflow.
The listed cold-start inrush current is 45 A at 230 V AC. This is a brief AC input-side surge at power-on—not DC load current—and should be considered when sizing upstream breakers or fuses, especially with multiple units on one circuit.
LRS-35 is rated for 1.5 kV (I/P–O/P), 1.5 kV (I/P–FG), and 0.5 kV (O/P–FG) for 1 minute, with 100 MΩ insulation resistance at 500 V DC (25 °C / 70% RH).
Include the exact model (e.g., LRS-35-24), quantity, destination country, input mains voltage, and continuous/peak load current. Standard packing is 80 pcs per carton (44 × 36.5 × 19.5 cm, 16 kg); mention any tight-enclosure or labeling needs.
Include the selected model and your project requirements in the inquiry form.

In the inquiry form, enter model LRS-35-5LRS-35-12LRS-35-15LRS-35-24LRS-35-48.



Boost your business with WEHO quality power supply prooducts.
Ask an Expert